テキスト内容
この資料から読み取れるテキストです。
TEST REPORT
TEST OF A HYBRID WOOD STOVE FOR EMISSIONS AND EFFICIENCY
PER EPA METHODS 28R AND ASTM E2515 and ASTM E2780, MAY 2015
Client:
Hearthstone
317 Stafford ave.
Morrisville, Vt 05661
Model name: Green Mountain 60
Attention: Rafaël Sanchez
TESTED BY:
Services Polytests Inc.
695-B Gaudette
St-jean-sur-Richelieu, QC, J3B 7S7
TEST DATES: January 15th to 22nd 2018
REPORT DATE: February 6th 2018
Project number: PI-20162
All services undertaken are subject to the following general policy: Reports are submitted for exclusive use of the clients to whom they are
addressed. Their significance is subject to the adequacy and representative character of the samples and to the comprehensiveness of the tests,
examinations or surveys made. This document may not be reproduced except in its entirety without the written permission from Services Polytests
Services Polytests have not been involved in any R&D design consulting regarding this unit as requested by the NSPS..
Tested:
written by:
Maxime Martin
Danick Power, P. Eng
Verified by third party certifier (PFS):
St-jean-sur-Richelieu, February 6th 2018
Client: Hearthstone
Project: PI-20162
Model: GM-60
Page 2 of 28
M_rap_EPAwoodstove V1 – 2015 july 30th
SUMMARY
1
Introduction .................................................................................................................................................. 5
1.1
General ................................................................................................................................................. 5
1.2
Test unit information ........................................................................................................................... 5
1.3
Results .................................................................................................................................................. 5
1.4
Pretest information .............................................................................................................................. 6
2
Summary of test results ................................................................................................................................ 6
2.1
Emissions .............................................................................................................................................. 6
2.2
Average calculation .............................................................................................................................. 7
2.3
Test facility conditions ......................................................................................................................... 7
2.4
Fuel qualities ........................................................................................................................................ 8
2.5
Dilution tunnel flow rate measurements and sampling data (ASTM E2515) ....................................... 8
2.6
Dilution tunnel dual train precision ..................................................................................................... 9
2.7
General summary of results ................................................................................................................. 9
3
Process description ..................................................................................................................................... 10
3.1
Discussion .......................................................................................................................................... 10
3.2
Unit dimensions ................................................................................................................................. 10
3.3
Air supply system ............................................................................................................................... 11
3.4
operation during test ......................................................................................................................... 12
3.5
Start-up operation ............................................................................................................................. 12
3.6
Sampling locations ............................................................................................................................. 13
3.7
Drawings ............................................................................................................................................ 13
3.8
Emissions efficiency testing equipment list ....................................................................................... 13
4
Sampling methods ...................................................................................................................................... 13
4.1
Particulate sampling .......................................................................................................................... 13
5
Quality assurance ....................................................................................................................................... 13
5.1
Instrument calibration ....................................................................................................................... 13
5.1.1
Gas meters ..................................................................................................................................... 13
5.1.2
SCALES ........................................................................................................................................... 13
5.1.3
Gas analyzers ................................................................................................................................. 13
5.2
Test method procedures .................................................................................................................... 14
5.2.1
Leak check procedures .................................................................................................................. 14
5.2.2
Tunnel velocity flow measurement ............................................................................................... 14
St-jean-sur-Richelieu, February 6th 2018
Client: Hearthstone
Project: PI-20162
Model: GM-60
Page 3 of 28
M_rap_EPAwoodstove V1 – 2015 july 30th
5.2.3
Pm sampling proportionality (ASTM E2515) ................................................................................. 14
St-jean-sur-Richelieu, February 6th 2018
Client: Hearthstone
Project: PI-20162
Model: GM-60
Page 4 of 28
M_rap_EPAwoodstove V1 – 2015 july 30th
List of appendix
APPENDIX 1: Raw data, forms and results
APPENDIX 2: Proportionality results
APPENDIX 3: Calibration data
APPENDIX 4: Unit pre burn
APPENDIX 5: Participants
APPENDIX 6: Drawings and specifications
APPENDIX 7: Operator’s manual
APPENDIX 8: Photographs of test set up
APPENDIX 9: Test load photographs
APPENDIX 10: Laboratory Operating Procedures
APPENDIX 11: Sample calculations
APPENDIX 12: Volume calculations
APPENDIX 13: Operating instruction
APPENDIX 14: Drawing Air flow pattern
St-jean-sur-Richelieu, February 6th 2018
Client: Hearthstone
Project: PI-20162
Model: GM-60
Page 5 of 28
M_rap_EPAwoodstove V1 – 2015 july 30th
1 INTRODUCTION
1.1 GENERAL
Laboratory
•
Location: Services Polytests Inc., 695-B Gaudette St-jean-sur-Richelieu QC, Canada J3B 7S7
•
Elevation: 100 feet above sea level
Test program
•
Purpose: unit qualification NSPS 2020
•
Test dates: January 15th to 22nd 2018
•
Test methods used:
o
Particulate emissions: ASTM E2780-10 ; ASTM E2515-11 methods 28R as referred into 40
CFR Part 60 Subpart AAA
o
Efficiency: CSA B415.1-10
1.2 TEST UNIT INFORMATION
General
•
Manufacturer: Hearthstone
•
Product type: Hybrid wood stove
•
Combustion system: catalytic, with post combustion
•
Unit tested: GM 60
•
Option : optional convection fan can be installed on the wood stove
1.3 RESULTS
Emission results obtained
•
Weighted Average emission rate: 0.62 grams/hour
•
Weighted Average Efficiency : 79.2 %
•
Weighted Average Co : 0.39 grams/min
Conformity: NSPS Phase 2020
St-jean-sur-Richelieu, February 6th 2018
Client: Hearthstone
Project: PI-20162
Model: GM-60
Page 6 of 28
M_rap_EPAwoodstove V1 – 2015 july 30th
1.4 PRETEST INFORMATION
Unit condition: The unit was received first week of January 2018 in good condition. The 50hrs of aging is
made by the manufacturer (all data in Appendix 4).
Set up
•
Venting system type: 6 inch diameter insulated chimney
•
System height from floor: 15 feet
•
Particularities: The unit was tested with the convection Fan ON for average numbers (Test #1, 2, 4
and 5), and one confirmation test is done without any convection fan (test #3).
Break in period
•
Duration: the unit was pre burned by the manufacturer and run for at least 50 hours, adequate
documentation of fuel additions, flue and unit temperatures recorded.
•
Fuel: BC FIR between 19% and 25%
2 SUMMARY OF TEST RESULTS
2.1 EMISSIONS
Run
Number
Test Date
(AAA-MM-
DD)
Emission
Rate (g/hr)
Burn Rate
(kg/hr)
1st hour
Emission
Rate (g/hr)
CSA B415.1
CO emission
Gr/hr
CSA B415.1
CO emission
Gr/Kg dry
1
2018-01-15
0,39
0,834
1,53
8,88
10,64
2
2018-01-16
0,20
1,239
0,41
21,14
17,05
3
2018-01-17
0,27
1,170
0,98
23,79
20,32
4
2018-01-18
0,78
1,604
2,35
32,83
20,45
5
2018-01-22
2,15
2,370
4,38
51,43
21,70
St-jean-sur-Richelieu, February 6th 2018
Client: Hearthstone
Project: PI-20162
Model: GM-60
Page 7 of 28
M_rap_EPAwoodstove V1 – 2015 july 30th
2.2 AVERAGE CALCULATION
Test No.
Burn
Rate
(Kg/hr)
(E)
Ave.
Emission
Rate g/hr
(OHE)
%
Heat
Output
(BTU/HR)
CSA B415.1
CO emission
g/min
1
0,83
0,395
80,42%
12 608
0,15
2
1,24
0,199
80,29%
18 702
0,35
4
1,60
0,777
77,81%
23 468
0,55
5
2,37
2,153
75,37%
33 576
0,86
Weighted particulate emission average of 4 test runs: 0.62 grams per hour.
Weighted average HHV efficiency of 4 test runs: 79.2 %.
Average Co 0.39 gr/min
2.3 TEST FACILITY CONDITIONS
Run
Number
Room
Temperature
Barometric
pressure
Relative
humidity
Air Velocity
Before
After
Before
After
Before
After
Before
After
(F)
(F)
(in.Hg)
(in.Hg)
(%)
(%)
(ft/min)
(ft/min)
1
68
69
30,357
30,298
19
22
6
9
2
71
73
30,327
30,298
16,8
16,9
5
3
3
71
73
30,268
30,121
19,1
20,1
4
6
4
72
72
29,914
29,855
18,7
19
4
8
5
71
73
30,268
30,180
27,1
22,4
4
5
St-jean-sur-Richelieu, February 6th 2018
Client: Hearthstone
Project: PI-20162
Model: GM-60
Page 8 of 28
M_rap_EPAwoodstove V1 – 2015 july 30th
2.4 FUEL QUALITIES
Run
Number
Pre-test Load
Test Load
Loading
Weight
Wet
Basis
(lbs)
Moisture
Content
Dry
Basis
(%)
Coal
bed
Weight
(lbs)
Weight
Wet
Basis
(lbs)
Density
Wet
Basis
(lbs/cuft)
Moisture
Content
Dry
Basis
(%)
Piece
Length
(in.)
Number
of
2X4's
Number
of
4x4's
Number
of
Spacers
1
16,24
20,49
2,7
13,07
6,439
20,50
17,25
2
2
12
2
15,98
21,55
2,6
13,29
6,547
20,61
17,5
2
2
12
3
16,55
21,67
2,7
13,09
6,450
20,37
17,25
2
2
12
4
16,88
21,49
2,9
13,28
6,540
20,45
17,25
2
2
12
5
15,48
22,34
2,7
13,59
6,694
20,03
17
2
2
12
2.5 DILUTION TUNNEL FLOW RATE MEASUREMENTS AND SAMPLING DATA (ASTM E2515)
Average dilution tunnel measurements
Sample Data
Run
Number
Burn
Rate
(Min)
Volumetric
Flow Rate
(dscf/min)
Total
Temperatures
(°R)
Volume sampled
(DSCF)
Particulate catch
(mg)
1
2
1
2
1
354
175,47
545,21
61,090
61,665
2,40
2,20
2
242
176,34
547,59
42,193
42,845
0,80
0,80
3
253
171,49
550,62
44,253
44,804
1,20
1,10
4
187
165,15
559,40
32,827
33,546
2,80
2,50
5
130
160,60
577,05
22,384
22,838
5,30
4,80
St-jean-sur-Richelieu, February 6th 2018
Client: Hearthstone
Project: PI-20162
Model: GM-60
Page 9 of 28
M_rap_EPAwoodstove V1 – 2015 july 30th
2.6 DILUTION TUNNEL DUAL TRAIN PRECISION
Run
Number
Sample Ratio
Total Emission (g)
Train 1
Train 2
Train 1
Train 2
% Deviation
1
1016,80
1007,31
2,44
2,22
4,82%
2
1011,39
996,00
0,81
0,80
0,77%
3
980,45
968,39
1,18
1,07
4,97%
4
940,80
920,63
2,59
2,26
6,91%
5
932,69
914,14
4,94
4,39
5,95%
2.7 GENERAL SUMMARY OF RESULTS
Run
Number
Burn
Rate
(kg/hr)
Average
Surface
Temperature
(F)
Change in
surface
Temperature
(F)
Initial
Draft
(in. H2O)
static pressure
tunnel
(in. H2O) neg.
Primary
Air
Setting
Run
Time
(min)
1
0,834
298,35
-57,5
0,055
0.39
min
354
2
1,239
366,37
-61,1
0,067
0.40
Cat 2 setting
242
3
1,170
406,38
-59,3
0,065
0.39
Cat 2 setting
253
4
1,604
416,97
-75,9
0,075
0.39
Cat 3 setting
187
5
2,370
473,27
-51,4
0,084
0.37
Full open
130
St-jean-sur-Richelieu, February 6th 2018
Client: Hearthstone
Project: PI-20162
Model: GM-60
Page 10 of 28
M_rap_EPAwoodstove V1 – 2015 july 30th
3 PROCESS DESCRIPTION
3.1 DISCUSSION
The unit was delivered by the client and received in a good condition. Four Preliminary runs were done at the
lab to ensure repeatability of testing done by manufacturer at his location before official test series. Four runs
have been done for weighted average with the optional convection fan at “ON” position. One confirmation
test was done without the optional convection fan.
3.2 UNIT DIMENSIONS
Baffle
•
Location: between top of combustion chamber and hearth
•
Restriction: 2.5 inch X 18 inch at the front of the unit
•
Dimensions: cover the hearth area minus the restriction at the front
•
Material: Vermiculite 1 inch thick.
Bricks
•
Inside firebox refractory brick 1¼ inch. thick cover all the sides and the back of the combustion
chamber bottom covered by ½ thick refractory brick
Flue gas exhaust
•
Location: top flue
•
Dimensions: 6 in. diameter
•
Material: Cast Iron
Gasket
•
Window : 1/4 Round
•
Door gasket against facing: fiberglass 3/8 round inch diameter
•
Refer to appendix 6 for complete list and location of each gaskets
Overall unit dimension
•
Overall dimensions : 25 7/8 inch wide x 19 1/4 inch deep x 29 ¼ inch high
•
Usable volume : 2.03 cuft
Convection fan
•
Optional Convection fan blower:
•
Free air : 150 CFM 110-120V (ref. : PT#90-57000)
Catalyst (appendix 6 for details):
•
Applied Ceramics – P/N WF-4150001076
•
Cell density: 50 CPSI
•
Material : 16 Ga SS430 or 304
•
Catalyst temperature probe located on the right side of the stove just behind by-pass handle
St-jean-sur-Richelieu, February 6th 2018
Client: Hearthstone
Project: PI-20162
Model: GM-60
Page 11 of 28
M_rap_EPAwoodstove V1 – 2015 july 30th
3.3 AIR SUPPLY SYSTEM
Description
•
Primary air: Window wash design in cast iron channel fully gasketed on the top and bottom of the
combustion chamber. Air intake on the middle-left side of the unit (if facing door of stove)
•
Secondary air: secondary tube design with air intake coming from the bottom rear of unit, then up
through a steel riser tube to the secondary air tube.
Characterization
The following table shows the inlet and outlet sections of each system. The air introduction system number is
referred to on a set of drawings in Appendix 6.
AIR INTRODUCTION SYSTEM
INLET (1) sq. in.
OUTLET
(sq. in.)
Identification
Type
Imin
Imax
Controlled
APPENDIX 14
SHARED and PA
Primary
(air control Slide)
0.312
(air control Slide)
4.610
yes
(Air Wash)
5.284
APPENDIX 14
SHARED and SA
Secondary
(Riser opening)
0.600
(Riser opening)
0.600
yes
(Secondary
Tube holes)
2.071
Appendix 14 TA
Pilot
(Orifice)
0.028
(Orifice)
0.028
None
(Orifice)
0.096
* This section would be filled by measuring and comparing with the manufacturer’s drawings included in the
test report.
Legend
Identification: Tag name referred to on drawings in Appendix 14, section airflow pattern
Type: Characterization of air intake
Imin: Minimum air intake of a particular air channel
Imax: Maximum air intake of a particular air channel
Controlled: Determines if a provision for air control is present
Outlet: Total air outlet of a particular air channel
St-jean-sur-Richelieu, February 6th 2018
Client: Hearthstone
Project: PI-20162
Model: GM-60
Page 12 of 28
M_rap_EPAwoodstove V1 – 2015 july 30th
3.4 OPERATION DURING TEST
Run #1
This run was performed on January 15th 2018. It lasted 354 minutes and a 0.83 kg/hr burn rate was obtained
& emission at 0.39 gr/hr. The optional convection fan Option was operated as per user’s manual during the
test.
Run #2
This run was performed on January 16th 2018. It lasted 242 minutes and a 1.24 kg/hr burn rate was obtained
& emission at 0.2 gr/hr. The optional convection fan Option was operated as per user’s manual during the
test.
Run #3
This run was performed on January 17th 2018. It lasted 253 minutes and a 1.17 kg/hr burn rate was obtained
& emission at 0.27 gr/hr. The optional convection fan Option was at OFF position during the entire test.
Run #4
This run was performed on January 18th 2018. It lasted 187 minutes and a 1.604 kg/hr burn rate was obtained
& emission at 0.78gr/hr. The optional convection fan Option was operated as per user’s manual during the
test.
Run #5
This run was performed on January 22nd 2018. It lasted 130 minutes and a 2.37 kg/hr burn rate was obtained
as maximum output & emission at 2.15gr/hr. The optional convection fan Option was operated as per user’s
manual during the test.
•
Details: Refer to the front page of each test run data sheets found in appendix for the detailed test
sequence showing air supply settings and adjustments, fuel bed adjustments and operational
specifics of the test unit.
Test fuel cribs
•
Type of wood: Douglas fir, grade c or better, 19 to 25% dry basis moisture content
•
Description: for each test, description of the fuel crib is found on the front page of each test run data
sheet together with photograph in appendix.
3.5 START-UP OPERATION
The complete manufacturer’s firing procedure of each burn rate category is fully described in appendix 13.
St-jean-sur-Richelieu, February 6th 2018
Client: Hearthstone
Project: PI-20162
Model: GM-60
Page 13 of 28
M_rap_EPAwoodstove V1 – 2015 july 30th
3.6 SAMPLING LOCATIONS
Particulate samples are collected from the dilution tunnel at a point 15 feet from the tunnel entrance. The
tunnel has two elbows and two mixing baffles in the system ahead of the sampling section. The sampling
section is a continuous 15 foot section of 6 inch diameter pipe straight over its entire length. Tunnel velocity
pressure is determined by a standard pitot tube located 48 inches from the beginning of the sampling section.
Thermocouple is installed on the pitot tube to measure the dry bulb temperature. MC is assumed, as allowed,
to be 4%. Tunnel samplers are located 56 inches downstream of the pitot tube and 16 inches upstream from
the end of this section.
3.7 DRAWINGS
Various drawings of the stack gas sampling train and of dilution tunnel system are found in Appendix 1.
3.8 EMISSIONS EFFICIENCY TESTING EQUIPMENT LIST
The complete test equipment list together with all corresponding calibration data can be found in Appendix 3.
4 SAMPLING METHODS
4.1 PARTICULATE SAMPLING
Particulates were sampled in strict accordance with ASTM E2515. This method uses two identical sampling
systems with Gelman A/E 61631 binder free (or equivalent), 47 mm diameter filters. The dryers used in the
sample systems are filled with "Drierite" before each test run.
5 QUALITY ASSURANCE
5.1 INSTRUMENT CALIBRATION
5.1.1 GAS METERS
At the conclusion of each test program the gas meters are verified using the reference dry gas meter. This
process involves sampling the train operation for 1 cubic foot of volume. With readings made to .01 fr', the
resolution is 1 %, giving an accuracy higher than the 2% required by the standard.
5.1.2 SCALES
Before each test program, the different scales used are checked with traceable calibration weights to ensure
their accuracy.
5.1.3 GAS ANALYZERS
The continuous analyzers are zeroed and spanned before each test with NBS traceable gases. A mid-scale
multi-component calibration gas is then analyzed (values are recorded). At the conclusion of a test, the
St-jean-sur-Richelieu, February 6th 2018
Client: Hearthstone
Project: PI-20162
Model: GM-60
Page 14 of 28
M_rap_EPAwoodstove V1 – 2015 july 30th
instruments are checked again with zero, span and calibration gases (values are recorded only). The drift in
each meter is then calculated and must not exceed 5% of the scale used for the test.
5.2 TEST METHOD PROCEDURES
5.2.1 LEAK CHECK PROCEDURES
Before and after each test, each sample train is tested for leaks. Leakage rates are measured and must not
exceed 0.02 CFM or 4% of the sampling rate. Leak checks are performed checking the entire sampling train.
Pre-test and post-test leak checks are conducted with a vacuum of 5 inches of mercury. Vacuum is monitored
during each test and the highest vacuum reached is then used for the post-test vacuum value. If leakage limits
are not met, the test run is rejected. During these tests, the vacuum is typically less than 2 inches of mercury.
Thus, leakage rates reported are expected to be much higher than actual leakage during the tests.
5.2.2 TUNNEL VELOCITY FLOW MEASUREMENT
The tunnel velocity is calculated from a center point pitot tube signal multiplied by an adjustment factor. This
factor is determined by a traverse of the tunnel as prescribed in EPA Method 1. Final tunnel velocities and
flow rates are calculated from EPA Method 2, Equation 6.9 and 6.10. (Tunnel cross sectional area is the
average from both lines of traverse.)
Pitot tubes are cleaned before each test and leak checks are conducted after each test.
5.2.3 PM SAMPLING PROPORTIONALITY (ASTM E2515)
Proportionalities were calculated in accordance with ASTM E2515. The data and results are found in appendix.
St-jean-sur-Richelieu, February 6th 2018
Client: Hearthstone
Project: PI-20162
Model: GM-60
Page 15 of 28
M_rap_EPAwoodstove V1 – 2015 july 30th
APPENDIX 1: Raw data, forms and results
DATA 2018-01-15 EPA PI 20162 RUN1 CAT1 MODEL GM 60
Paramètres
Tous les facteurs de corrections et autres paramètres qui peuvent être modifiés par
l’utilisateur du fichier sont regroupés ici.
Code verrouillage:
HEA
Description du test
Test standard
EPA
Run #
1
Date
15-01-2018
Technicien
M.M
Project #
PI 20162
Description de l'unité
Manufacturier
HEARTHSTONE
Modèle
GM 60
Combustion system
Cat
Appliance type
WOOD STOVE
Firebox volume
2,03
cu ft.
Appliance weight empty
N.A
lbs
Appliance weight full
N.A
lbs
Paramètres du test
Logging time
1
min
Manufacturer's rated heat output
BTU/h Donnée fournie par le manfacturier
Targeted category
1
Targeted output
N.A
BTU/h
Cp steel
N.A
BTU/lb-°F
Échantillonnage
Blank sampling rate
0,20
cuft/min
Internal probe diameter
0,18
in.
Calibration Factor (DGM #1):
0,988
Dimensionless
Equipment number (DGM #1):
EM 178
Calibration Factor (DGM #2):
0,988
Dimensionless
Equipment number (DGM #2):
EM 179
Calibration Factor (DGM #3):
0,986
Equipment number (DGM #3):
EM 070
Dimensionless
Tunnel
Targeted tunnel flow rate
160
scfm
Tunnel diameter
6
in.
Molecular weight
28,78
May be assumed to be 28,78 (EPA) Si B-415 = 29
Pitot tube type
Standard
Pitot tube coefficient
0,99
Dimensionless
Project nu. PI 20162
Date
15-01-2018
Technicien
M.M
Fuel data
Fuel type
Dimension
Fuel specie
D. Fir
HHV
19810,0 kJ/kg
D. Fir
Oak/Maple
%C
48,7
HHV
19 810
19 887
%H
6,9
%C
48,73
50
%O
43,9
%H
6,87
6,6
%Ash
0,5
%O
43,9
42,9
HHV
8519,2 Btu/lb
%Ash
0,5
0,5
LHV
7451,0 Btu/lb
HHV (Btu/lb)
8519
8552
LHV (Btu/lb)
7451
7480
Default Fuel Values
Paramètres
Page 1 of 1
DATA 2018-01-15 EPA PI 20162 RUN1 CAT1 MODEL GM 60
Preload data sheet
Lower
Ideal
Upper
12,79
14,21
15,63
Load Volume:
0,5185
cu. ft
Loading Density:
8,002
lbs./ft3
Number of Spaces:
Load Density (wet):
31,328
lbs./ft3
Spacer weight (lbs):
Dry Wood Density:
26,000954
Weight
Ave. MC x
Volume
Thick Wide x Length
lbs
Weight
Cubic Inches
2
4
8
1,056
20,6
20,3
20,9
21
20,9
21,90144
64,00
2
4
8
1,34
20,8
20,4
20,9
20,8
21,4
27,9524
64,00
2
4
8
1,05
21,3
21,6
21,4
21,3
21,2
22,428
64,00
2
4
8
1,39
21
21,1
21,6
20,9
20,8
29,3012
64,00
2
4
8
1,38
20,4
20,3
20,8
20,4
20,7
28,3176
64,00
2
4
8
1,04
20,9
20,8
20,4
20,3
20,3
21,3616
64,00
2
4
8
1,07
20,9
21
21,3
21,6
21,3
22,7054
64,00
2
4
8
1,048
20,8
20,8
20,6
20,9
20,8
21,77744
64,00
2
4
8
1,52
20,7
19,9
19,6
19,3
19,5
30,096
64,00
2
4
8
1,08
19,6
19,4
20
20,1
20,2
21,4488
64,00
2
4
8
1,084
20,4
20,6
20,8
20,3
20,1
22,15696
64,00
2
4
8
1,102
20,8
20,3
20,4
20,6
20,8
22,67916
64,00
2
4
8
1,036
19,6
19,3
19,1
19,3
19,2
19,9948
64,00
2
4
8
1,048
19,6
19,4
19,9
19,8
19,9
20,66656
64,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
SUM MCx 332,78736
PreTest Load Weight:
16,24
lbs.
Dry Weight:
6,12
kg.
Average Moisture Content: %
Dry:
20,49
20,49
Wet:
17,00
Must be 18-28
must be 15,2-22
Project nu. PI 20162
Date
15-01-2018
Technicien
M.M
Test Load Weight:
Piece Size (in):
Meter Moisture Content
Dry Uncorrected %
Preload Data
Page 1 of 1
Confidentiel
06/02/2018
Page 1
FUEL LOAD DATA SHEET, CSA B415
Lower
Ideal
Upper
12,8
14,2
15,6
* For boilers, a loading density factor of 10 lb/ft3 is applied
Load Volume:
0,43
cu. ft
Loading Density:
6,4
lbs./ft3
Number of Spaces:
12
Load Density (wet):
30,6
lbs./ft3
Spacer weight:
lbs
Dry Wood Density:
25,4
lbs./ft3
Weight
Ave. MC x
Volume
Ave. MC
Thick Wide xLength
lbs
Weight
Cubic Inches
%
1,5
3,5
17,25
1,95
21,10
20,60
20,30
20,80
20,60
40,40872
90,56
20,7
1,5
3,5
17,25
1,89
19,40
19,90
19,30
19,80
19,40
37,00752
90,56
19,6
3,5
3,5
17,25
4,06
20,60
20,10
19,90
20,10
20,30
81,9312
211,31
20,2
3,5
3,5
17,25
3,90
21,00
21,30
20,70
20,60
20,90
81,4682
211,31
20,9
1,5
0,75
5
0,10
21,00
2,142
5,63
21,0
1,5
0,75
5
0,10
21,30
2,1726
5,63
21,3
1,5
0,75
5
0,10
20,80
2,08
5,63
20,8
1,5
0,75
5
0,11
20,90
2,2154
5,63
20,9
1,5
0,75
5
0,10
22,10
2,21
5,63
22,1
1,5
0,75
5
0,11
22,30
2,4084
5,63
22,3
1,5
0,75
5
0,11
21,60
2,4192
5,63
21,6
1,5
0,75
5
0,11
21,40
2,354
5,63
21,4
1,5
0,75
5
0,10
21,80
2,2236
5,63
21,8
1,5
0,75
5
0,09
21,60
2,0304
5,63
21,6
1,5
0,75
5
0,11
21,00
2,268
5,63
21,0
1,5
0,75
5
0,13
21,00
2,688
5,63
21,0
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
SUM MCx 268,02724
21,1 %
Test Load Weight:
13,07
lbs.
Dry Weight:
4,92
kg.
Average Moisture Content: %
Dry:
20,50
Dry(EPA)
20,50
20,50
Wet:
17,02
Dry(B415
20,50
Must be 19-25
must be 15,2-22
Coal Bed Range:
2,6
lbs. to
3,3
lbs.
TEST CHARGE:
Project nu. PI 20162
Coal bed weight:
2,7
lbs.
Date
15-01-2018
Technicien
M.M
Test Load Weight:
Piece Size (in):
Meter Moisture Content
Dry Uncorrected %
Load Data
Page 1 of 1
DATA 2018-01-15 EPA PI 20162 RUN1 CAT1 MODEL GM 60
Filter set weight
Ambient
blank (g)
Date
Heure
probe
front
back
gasket
probe
front
back
gasket
probe
front
back
gasket
Filter
Number
17
7
8
21
18
9
10
22
50
11
12
23
13
Before (1)
Before (2)
Before (3)
Before (4)
Before (5)
108,9499
0,1289
0,1280
35,4196
108,9471
0,1281
0,1274
35,1414
107,6467
0,1256
0,1243
35,1863
0,1263
11/01/2018
17:00
Before (6)
108,9498
0,1288
0,1279
35,4195
108,9471
0,1280
0,1274
35,1413
107,6466
0,1256
0,1243
35,1864
0,1264
15/01/2018
10:00
After (1)
108,9514
0,1288
0,1270
35,4230
108,9486
0,1277
0,1269
35,1435
107,6478
0,1249
0,1233
35,1900
0,1264
15/01/2018
08:00
After (2)
108,9505
0,1285
0,1269
35,4222
108,9476
0,1277
0,1268
35,1429
107,6469
0,1248
0,1233
35,1894
0,1264
29/01/2018
08:00
After (3)
108,9505
0,1285
0,1269
35,4217
108,9476
0,1277
0,1268
35,1427
107,6470
0,1251
0,1234
35,1897
0,1264
01/02/2018
08:00
After (4)
108,9505
0,1285
0,1269
35,4216
108,9476
0,1277
0,1268
35,1426
107,6470
0,1251
0,1234
35,1896
0,1264
05/02/2018
08:00
After (5)
After (6)
108,9505
0,1285
0,1269
35,4216
108,9476
0,1277
0,1268
35,1426
107,6470
0,1251
0,1234
35,1896
0,1264
05/02/2018
08:00
Difference
0,0007
-0,0003
-0,0010
0,0021
0,0005
-0,0003
-0,0006
0,0013
0,0004
-0,0005
-0,0009
0,0032
0,0000
Total (mg)
1,5
2,4
2,2
0
Total ajusté (mg)
1,50
2,40
2,20
Project nu. PI 20162
Date
15-01-2018
Technicien
M.M
System 2 (g)
System 1 (g) 1st hour
System 1 (g)
Filter set weight
Page 1 of 1
DATA 2018-01-15 EPA PI 20162 RUN1 CAT1 MODEL GM 60
SFBA EPA EMISSION RESULTS
RESULTS
Average emission rate:
0,4
g/hr
Burn Rate :
0,834
Dry kg/hr
Test Duration:
354
min
PRESSURE FACTOR:
DGM 1
0,98829
BAROMETRIC PRESSURE
DGM 2
0,98803
Average:
30,327299 in Hg
DGM 3
1,01361
Start:
30,356829 in Hg
End:
30,297769 in Hg
TEMPERATURE FACTORS
DGM 1
0,98793
DGM 2
0,98688
DGM CONTROLLER VALUES
DGM 3
0,99725
DGM 1
Final: 21850,412
Cuft
Initial: 21787,075
Cuft
VOLUMES SAMPLED
DGM 1
61,090
SCft
DGM 2
Final: 19238,958
Cuft
DGM 2
61,665
Scft
Initial: 19174,976
Cuft
DGM 3
43,034
SCft
DGM #3
Final:
650,240
Cuft
Initial:
607,080
Cuft
TOTAL TUNNEL VOLUME :
62116
TEMPERATURES
SAMPLE RATIOS
DGM 1
534,450
°R
Sample Train 1:
1016,804
DGM 2
535,019
°R
Sample Train 2:
1007,314
CALIBRATION FACTORS
Paticulate concentration
DGM 1
0,9879
Sample Train 1
0,000039
g/dscf
DGM 2
0,9884
Sample Train 2
0,000036
g/dscf
DGM #3
0,9864
Room
0,000000
g/dscf
TUNNEL FLOW RATE:
175,469
Dscfm
TOTAL EMISSIONS
PARTICULATE CATCH
Sample Train 1
2,44
g
Total Sample Train 1:
2,40 mg
Sample Train 2
2,22
g
Total Sample Train 2:
2,20 mg
Total Sample Train 1 1st hour:
1,50 mg
EMISSION RATES
Sample Train 1
0,41
g/hr
Sample Train 2
0,38
g/hr
1st hour emission rate
1,53
g/hr
DEVIATION:
4,82%
Train 1
Train 2
Cs
3,929E-05
3,56766E-05
Particulates Calculations
Page 1 of 1
DATA 2018-01-15 EPA PI 20162 RUN1 CAT1 MODEL GM 60
Average
0,04
9,91
#DIV/0!
215,02
69,46
84,29
320,65
219,48
311,15
296,92
343,56
*****
*1
*2
*3
*4
*5
*6
*7
*8
Elapsed
Weight
Flue
Room
Tunnel
Unit
Unit
Unit
Unit
Unit
Time
Raw data row
Remaining
CO
CO2
O2
Gas
Temp
Dry Bulb
Top
Back
R.Side
L.Side
Bottom
min
lbs
%%%
°F
°F
°F
°F
°F
°F
°F
°F
0,00
209,00
13,1
0,1
1,3
0,0
235,1
68,4
132,9
280,0
235,6
325,3
304,9
518,0
1,0
210,0
12,8
0,2
1,2
0,0
244,2
68,7
101,9
279,2
251,0
323,9
303,9
511,7
2,0
211,0
12,7
0,2
1,3
0,0
282,2
69,4
99,6
284,3
263,0
322,8
302,7
508,2
3,0
212,0
12,6
0,1
1,8
0,0
321,5
69,2
100,4
297,1
272,7
322,2
302,1
502,2
4,0
213,0
12,4
0,1
2,2
0,0
354,9
69,3
102,0
316,7
280,6
321,3
301,7
497,0
5,0
214,0
12,3
0,1
2,4
0,0
334,2
69,2
92,7
336,1
287,4
320,8
301,2
496,2
6,0
215,0
12,3
0,1
2,4
0,0
304,8
68,4
88,8
344,1
293,4
320,2
300,9
494,2
7,0
216,0
12,2
0,0
6,0
0,0
284,3
68,5
88,2
346,1
298,2
319,4
300,6
491,6
8,0
217,0
12,1
0,0
4,7
0,0
270,5
68,9
89,7
346,6
302,5
318,6
299,9
488,9
9,0
218,0
12,1
0,0
4,9
0,0
261,0
68,6
88,4
345,9
305,9
317,4
299,2
486,0
10,0
219,0
12,1
0,0
5,1
0,0
255,3
67,8
87,2
345,6
308,9
316,1
298,3
483,2
11,0
220,0
12,0
0,0
5,3
0,0
253,3
67,8
86,6
344,1
311,3
314,8
297,4
480,1
12,0
221,0
12,0
0,0
5,6
0,0
254,1
67,5
86,4
344,5
313,2
313,4
296,2
477,3
13,0
222,0
11,9
0,1
7,1
0,0
257,7
68,2
86,6
343,9
314,7
311,8
295,3
473,6
14,0
223,0
11,8
0,1
8,8
0,0
263,5
68,0
88,9
346,4
316,0
310,5
294,3
469,4
15,0
224,0
11,7
0,1
9,4
0,0
270,4
68,6
89,7
348,9
316,9
309,0
293,1
466,6
16,0
225,0
11,6
0,1
10,3
0,0
277,1
67,8
88,9
353,1
317,8
307,5
291,8
463,1
17,0
226,0
11,5
0,1
10,4
0,0
282,5
67,8
88,5
356,2
318,6
306,2
290,8
459,1
18,0
227,0
11,5
0,1
10,1
0,0
285,3
68,7
87,7
360,5
319,4
304,9
289,8
455,6
19,0
228,0
11,4
0,1
9,0
0,0
288,1
68,6
87,4
363,0
319,9
303,9
289,1
452,2
20,0
229,0
11,3
0,1
9,3
0,0
290,3
68,5
89,1
367,1
320,5
302,8
288,1
448,4
21,0
230,0
11,2
0,1
9,3
0,0
291,4
68,7
90,6
371,1
321,1
301,7
287,1
445,3
22,0
231,0
11,1
0,0
9,1
0,0
292,2
68,7
89,3
374,0
321,5
300,7
286,1
442,1
23,0
232,0
11,1
0,0
9,0
0,0
293,9
68,1
88,9
377,4
321,9
300,0
285,2
438,9
24,0
233,0
11,0
0,0
9,3
0,0
297,4
68,4
88,4
379,7
322,2
299,0
284,3
435,5
25,0
234,0
10,9
0,1
10,5
0,0
301,1
68,4
88,5
382,9
322,4
298,0
283,7
432,1
26,0
235,0
10,8
0,1
11,2
0,0
303,3
68,2
89,9
388,4
322,8
297,4
283,1
429,3
27,0
236,0
10,7
0,0
11,8
0,0
304,2
69,2
91,8
395,0
323,2
296,9
282,5
426,5
28,0
237,0
10,6
0,0
12,8
0,0
302,3
69,0
90,6
402,2
323,6
296,5
281,7
424,2
29,0
238,0
10,5
0,0
12,1
0,0
301,7
69,1
90,3
407,9
324,1
296,3
281,8
421,1
30,0
239,0
10,4
0,1
12,7
0,0
299,8
69,1
89,4
406,7
297,0
296,1
281,7
418,9
31,0
240,0
10,4
0,0
11,3
0,0
295,8
68,3
88,1
405,8
280,7
296,1
281,8
416,4
32,0
241,0
10,3
0,0
10,7
0,0
286,8
68,6
88,0
404,5
268,2
296,1
282,2
413,7
33,0
242,0
10,2
0,0
9,7
0,0
279,3
69,2
89,6
401,6
257,2
296,3
282,6
410,8
34,0
243,0
10,2
0,0
9,0
0,0
274,1
69,1
89,0
397,4
250,4
296,2
282,7
408,4
35,0
244,0
10,1
0,0
8,7
0,0
271,0
68,7
87,9
393,3
244,6
296,2
283,1
405,9
36,0
245,0
10,0
0,0
8,7
0,0
268,3
68,9
87,7
389,9
238,7
296,0
283,4
403,4
37,0
246,0
10,0
0,0
9,1
0,0
268,2
68,4
86,9
385,9
235,0
295,9
283,5
400,9
38,0
247,0
9,9
0,0
10,1
0,0
270,9
68,4
86,6
382,9
230,6
295,8
283,9
398,2
39,0
248,0
9,8
0,0
11,3
0,0
274,0
68,8
88,8
382,4
227,7
295,7
284,3
395,4
40,0
249,0
9,7
0,0
11,8
0,0
277,3
69,4
90,2
382,8
224,5
295,4
284,4
393,2
41,0
250,0
9,6
0,0
12,1
0,0
281,0
69,5
88,6
383,8
222,0
295,2
284,4
391,2
42,0
251,0
9,6
0,1
12,1
0,0
283,7
68,7
88,2
385,5
219,3
295,6
284,3
388,8
43,0
252,0
9,5
0,0
11,7
0,0
285,5
68,6
87,6
386,4
217,2
295,6
284,4
386,7
44,0
253,0
9,4
0,0
11,8
0,0
287,3
68,5
87,0
387,7
215,8
295,9
284,2
384,8
45,0
254,0
9,3
0,0
11,9
0,0
288,2
69,2
87,6
389,5
214,4
296,0
284,4
382,6
46,0
255,0
9,2
0,0
12,0
0,0
289,9
69,5
89,7
390,9
213,3
296,3
284,7
379,8
47,0
256,0
9,1
0,0
12,2
0,0
289,6
69,3
89,0
394,3
212,4
296,6
284,3
378,4
48,0
257,0
9,1
0,0
12,5
0,0
288,1
68,3
88,3
399,1
211,6
297,0
284,4
376,3
49,0
258,0
9,0
0,0
12,3
0,0
285,4
68,9
87,7
402,2
211,1
297,5
284,5
374,3
50,0
259,0
9,0
0,0
11,8
0,0
284,0
68,9
87,2
404,1
211,7
298,1
284,5
372,6
51,0
260,0
8,9
0,0
11,5
0,0
281,4
68,8
86,6
405,0
210,1
298,9
284,8
370,5
52,0
261,0
8,8
0,0
11,2
0,0
277,6
68,7
87,9
405,7
210,4
299,5
284,8
368,2
53,0
262,0
8,7
0,0
11,0
0,0
274,0
69,3
89,3
405,4
208,7
300,5
284,8
366,5
54,0
263,0
8,7
0,0
11,1
0,0
271,4
69,4
87,6
404,8
208,6
301,4
284,9
364,7
55,0
264,0
8,6
0,0
11,1
0,0
269,2
69,1
87,2
404,0
207,9
302,3
285,1
362,8
56,0
265,0
8,5
0,0
11,2
0,0
269,7
69,4
87,2
403,2
207,1
303,2
285,0
361,2
57,0
266,0
8,4
0,0
11,6
0,0
269,3
68,7
86,2
401,9
207,4
304,1
284,8
359,4
58,0
267,0
8,4
0,0
12,0
0,0
271,8
69,2
86,6
401,7
207,4
305,0
284,9
357,8
59,0
268,0
8,3
0,0
12,3
0,0
273,3
69,5
88,8
401,6
206,8
305,8
284,6
356,3
60,0
269,0
8,2
0,0
12,7
0,0
274,4
69,4
89,4
401,6
206,9
306,5
285,3
354,5
61,0
270,0
8,1
0,0
12,8
0,0
276,0
69,6
88,2
401,2
206,8
307,3
285,6
352,9
62,0
271,0
8,1
0,0
12,8
0,0
276,0
68,8
87,7
401,8
207,4
308,1
286,2
350,8
63,0
272,0
8,0
0,0
12,6
0,0
276,9
69,3
87,0
402,3
206,5
308,9
286,9
349,0
64,0
273,0
7,9
0,0
12,4
0,0
276,8
68,9
86,6
402,7
205,9
309,4
287,5
347,5
65,0
274,0
7,8
0,0
12,3
0,0
277,9
68,7
88,2
402,7
207,7
310,3
288,5
345,4
66,0
275,0
7,8
0,0
12,4
0,0
277,4
69,6
90,0
403,5
206,6
310,9
289,2
344,3
67,0
276,0
7,7
0,0
12,3
0,0
277,3
69,6
88,1
403,5
206,6
311,3
290,1
342,5
68,0
277,0
7,6
0,0
12,3
0,0
277,0
69,1
87,4
403,8
206,5
312,1
290,8
340,9
69,0
278,0
7,5
0,0
12,4
0,0
277,1
69,4
86,9
404,3
206,5
312,5
291,9
339,3
70,0
279,0
7,5
0,0
12,4
0,0
275,9
68,5
86,2
404,4
206,6
313,1
293,0
337,8
71,0
280,0
7,4
0,1
12,3
0,0
279,4
69,3
86,2
402,1
206,9
313,7
293,8
336,1
72,0
281,0
7,3
0,2
13,0
0,0
287,8
69,6
88,8
400,9
206,7
313,9
294,5
334,3
73,0
282,0
7,3
0,3
13,6
0,0
296,7
69,2
88,9
402,1
206,7
314,4
294,9
333,3
74,0
283,0
7,1
0,3
14,1
0,0
307,5
69,2
88,7
405,0
207,9
314,3
295,2
331,8
75,0
284,0
7,1
0,3
14,7
0,0
307,6
68,9
88,2
411,6
209,0
314,6
295,9
330,2
76,0
285,0
7,0
0,0
13,4
0,0
300,6
69,3
87,2
418,5
209,9
315,0
296,6
329,0
77,0
286,0
6,9
0,0
12,5
0,0
294,8
68,8
87,0
422,7
211,1
315,4
297,3
327,8
78,0
287,0
6,9
0,0
12,1
0,0
287,9
68,8
87,8
424,0
213,4
316,1
298,0
326,4
79,0
288,0
6,8
0,0
11,8
0,0
282,8
69,8
89,8
424,9
212,8
316,9
298,4
325,5
80,0
289,0
6,7
0,0
11,7
0,0
277,8
69,5
87,8
424,4
213,9
317,7
298,9
324,7
81,0
290,0
6,7
0,0
11,8
0,0
274,0
69,1
87,4
423,6
213,6
318,5
299,4
323,4
82,0
291,0
6,6
0,0
11,7
0,0
270,8
69,1
86,8
423,1
213,9
319,4
299,9
322,5
83,0
292,0
6,5
0,0
11,8
0,0
268,3
68,7
86,3
422,0
214,4
320,4
300,4
321,2
84,0
293,0
6,5
0,0
11,8
0,0
265,0
69,3
85,8
420,8
215,1
321,5
300,9
320,2
85,0
294,0
6,4
0,0
11,7
0,0
263,2
69,2
87,7
419,9
215,1
322,5
301,6
318,8
86,0
295,0
6,3
0,0
11,8
0,0
261,6
69,7
88,3
418,0
215,1
323,5
301,9
318,1
87,0
296,0
6,3
0,0
12,0
0,0
260,1
69,7
87,0
415,4
214,8
324,8
302,1
317,1
88,0
297,0
6,2
0,0
12,0
0,0
258,2
69,1
86,7
413,6
214,3
325,9
302,6
316,1
89,0
298,0
6,2
0,0
11,9
0,0
256,6
69,3
85,9
411,9
214,9
327,1
302,9
315,2
90,0
299,0
6,1
0,0
12,0
0,0
255,2
68,7
85,4
410,0
215,4
328,3
303,3
314,3
91,0
300,0
6,0
0,0
11,9
0,0
254,1
69,6
85,1
408,6
215,8
329,5
304,0
313,0
92,0
301,0
6,0
0,0
11,8
0,0
252,5
69,4
87,8
406,8
215,3
330,6
304,4
311,8
93,0
302,0
5,9
0,0
11,7
0,0
250,6
69,7
87,3
405,7
215,2
331,9
304,5
311,4
94,0
303,0
5,8
0,0
11,7
0,0
249,6
69,2
86,5
404,1
215,2
332,9
305,1
310,3
95,0
304,0
5,8
0,0
11,7
0,0
248,3
69,5
86,6
402,3
214,9
334,3
305,3
309,4
96,0
305,0
5,7
0,0
11,6
0,0
247,0
69,4
85,3
400,5
215,0
335,2
305,9
308,7
97,0
306,0
5,7
0,0
11,6
0,0
246,4
68,8
85,1
398,8
214,7
336,4
306,1
307,7
98,0
307,0
5,6
0,0
11,5
0,0
245,7
69,3
85,6
397,3
214,4
337,4
306,7
306,8
99,0
308,0
5,6
0,0
11,6
0,0
245,3
69,8
88,2
396,1
214,0
338,3
307,1
305,8
100,0
309,0
5,5
0,0
11,6
0,0
245,0
69,7
86,5
395,3
214,4
339,1
307,5
305,1
Particulates Calculations
Page 1 of 4
DATA 2018-01-15 EPA PI 20162 RUN1 CAT1 MODEL GM 60
101,0
310,0
5,4
0,0
11,8
0,0
244,4
68,9
86,1
394,0
214,0
339,9
308,0
304,1
102,0
311,0
5,4
0,0
11,8
0,0
243,5
69,2
85,4
393,3
214,1
341,0
308,4
303,5
103,0
312,0
5,3
0,0
11,9
0,0
243,3
68,3
85,0
392,9
214,2
341,6
309,0
302,5
104,0
313,0
5,3
0,0
12,0
0,0
242,2
69,2
84,5
392,8
213,5
342,2
309,6
301,7
105,0
314,0
5,2
0,0
12,0
0,0
241,6
69,1
86,1
392,3
214,6
342,9
310,3
300,7
106,0
315,0
5,1
0,0
11,9
0,0
246,2
69,9
88,3
389,6
213,9
343,4
310,6
300,2
107,0
316,0
5,1
0,1
13,6
0,0
258,4
69,9
86,6
387,1
214,1
343,7
310,7
299,7
108,0
317,0
5,0
0,1
14,6
0,0
274,8
69,1
87,6
388,3
214,2
343,8
311,2
298,8
109,0
318,0
5,0
0,1
15,1
0,0
280,0
69,9
86,3
394,1
214,8
343,9
311,6
298,0
110,0
319,0
4,9
0,0
13,4
0,0
276,5
69,1
85,9
400,3
216,2
344,0
312,0
297,4
111,0
320,0
4,8
0,0
12,8
0,0
270,8
69,4
85,3
405,1
216,5
344,3
312,4
296,9
112,0
321,0
4,7
0,0
12,5
0,0
265,3
69,0
86,8
407,5
217,3
344,5
313,0
296,0
113,0
322,0
4,7
0,0
12,3
0,0
260,1
70,0
88,0
408,7
217,5
344,9
313,6
295,7
114,0
323,0
4,6
0,0
12,1
0,0
256,2
70,0
86,2
409,1
218,4
345,4
314,2
295,2
115,0
324,0
4,5
0,0
12,2
0,0
253,5
69,7
86,0
409,4
218,1
345,9
314,9
294,5
116,0
325,0
4,5
0,0
12,2
0,0
250,6
70,0
85,3
408,5
218,5
346,3
315,6
294,3
117,0
326,0
4,4
0,0
12,2
0,0
248,4
69,5
84,9
407,7
218,2
346,8
316,3
293,9
118,0
327,0
4,3
0,0
12,0
0,0
246,3
69,6
84,3
406,4
218,7
347,3
317,2
293,2
119,0
328,0
4,3
0,0
12,1
0,0
245,0
70,3
86,5
405,8
218,8
347,8
318,1
292,2
120,0
329,0
4,2
0,0
12,0
0,0
242,5
70,2
86,4
404,8
219,1
348,3
318,5
292,0
121,0
330,0
4,2
0,0
11,5
0,0
240,5
69,9
85,4
403,0
219,7
349,1
319,6
291,4
122,0
331,0
4,2
0,0
11,1
0,0
238,7
70,0
84,9
400,7
219,9
349,5
320,0
290,7
123,0
332,0
4,1
0,0
11,0
0,0
236,8
70,0
84,7
398,9
219,5
350,2
320,5
290,4
124,0
333,0
4,1
0,0
10,9
0,0
235,3
69,5
83,8
395,5
220,0
350,5
321,2
289,6
125,0
334,0
4,0
0,0
10,6
0,0
234,0
70,2
83,7
392,5
219,7
350,9
321,8
288,9
126,0
335,0
4,0
0,0
10,5
0,0
232,6
70,2
86,3
389,7
219,4
351,2
322,4
288,3
127,0
336,0
3,9
0,0
10,5
0,0
230,7
70,6
85,2
387,5
219,2
351,3
322,6
288,1
128,0
337,0
3,9
0,0
10,7
0,0
229,2
69,8
85,0
384,3
219,4
351,5
322,9
287,9
129,0
338,0
3,9
0,0
10,7
0,0
228,3
70,3
84,5
381,9
219,7
351,7
323,1
287,7
130,0
339,0
3,8
0,0
10,7
0,0
227,2
69,6
83,9
379,5
219,4
351,7
323,5
287,4
131,0
340,0
3,8
0,0
10,9
0,0
226,5
69,5
83,7
377,3
219,7
351,7
324,0
287,0
132,0
341,0
3,7
0,0
11,0
0,0
225,4
70,1
83,6
376,1
219,5
351,6
324,3
286,7
133,0
342,0
3,7
0,0
11,1
0,0
224,8
70,3
86,0
375,0
219,1
351,4
324,8
286,1
134,0
343,0
3,6
0,0
11,2
0,0
223,9
70,6
84,8
373,6
219,8
351,4
324,9
286,2
135,0
344,0
3,6
0,0
11,5
0,0
223,3
69,8
84,5
372,4
220,3
351,2
325,7
285,6
136,0
345,0
3,6
0,0
11,3
0,0
222,5
70,6
84,6
371,5
220,1
350,9
325,9
285,7
137,0
346,0
3,5
0,0
11,3
0,0
222,0
70,1
83,5
371,0
220,0
350,6
326,2
285,6
138,0
347,0
3,5
0,0
11,3
0,0
221,2
69,9
83,0
370,5
220,4
350,5
327,0
285,3
139,0
348,0
3,4
0,0
11,4
0,0
220,1
70,5
83,0
370,1
220,5
350,2
327,8
284,7
140,0
349,0
3,4
0,0
11,3
0,0
219,0
70,3
85,4
369,8
220,6
349,8
328,5
284,5
141,0
350,0
3,4
0,0
10,9
0,0
218,5
70,7
84,7
369,3
220,2
349,6
329,0
284,5
142,0
351,0
3,3
0,0
10,8
0,0
217,6
69,6
84,0
368,3
220,8
349,2
329,6
284,5
143,0
352,0
3,3
0,0
10,2
0,0
216,2
69,9
83,8
367,1
220,7
348,9
330,0
284,5
144,0
353,0
3,2
0,0
10,1
0,0
215,5
70,0
83,0
364,5
220,8
348,4
330,4
284,3
145,0
354,0
3,2
0,0
10,4
0,0
215,2
69,3
82,5
362,1
219,7
347,7
331,0
284,3
146,0
355,0
3,2
0,0
10,5
0,0
215,0
70,6
82,4
360,7
220,7
347,1
331,3
284,3
147,0
356,0
3,2
0,0
10,6
0,0
214,6
70,1
85,0
359,1
220,1
346,4
332,0
283,9
148,0
357,0
3,1
0,0
10,9
0,0
214,5
70,6
84,7
358,3
220,3
345,7
331,9
284,3
149,0
358,0
3,1
0,0
11,0
0,0
214,3
70,3
83,7
357,3
220,0
345,0
332,5
283,9
150,0
359,0
3,0
0,0
11,1
0,0
214,0
69,8
83,5
356,4
220,0
344,3
332,9
284,2
151,0
360,0
3,0
0,0
11,1
0,0
213,8
70,4
82,8
355,9
220,3
343,6
333,1
284,4
152,0
361,0
3,0
0,0
11,2
0,0
212,9
69,4
82,5
355,6
219,5
342,9
333,6
284,3
153,0
362,0
3,0
0,0
11,1
0,0
212,3
69,9
82,1
355,1
219,9
342,0
334,2
284,4
154,0
363,0
2,9
0,0
11,1
0,0
211,8
70,5
84,7
354,3
220,0
341,1
334,8
284,1
155,0
364,0
2,9
0,0
11,2
0,0
211,1
70,4
84,8
354,0
219,8
340,4
335,4
284,5
156,0
365,0
2,8
0,0
11,2
0,0
210,1
70,0
83,6
353,4
220,1
339,7
335,8
284,7
157,0
366,0
2,8
0,0
11,1
0,0
209,5
70,3
83,6
353,2
219,6
339,0
336,4
284,8
158,0
367,0
2,8
0,0
11,0
0,0
208,4
69,9
82,7
352,1
219,5
338,5
336,7
285,2
159,0
368,0
2,8
0,0
10,8
0,0
207,7
69,5
82,1
350,8
219,0
337,7
337,0
285,5
160,0
369,0
2,8
0,0
10,5
0,0
207,3
70,1
81,8
349,0
218,5
337,1
337,8
285,5
161,0
370,0
2,7
0,0
10,2
0,0
207,4
69,9
84,3
347,0
219,8
336,4
338,1
285,5
162,0
371,0
2,7
0,0
10,1
0,0
207,1
70,5
84,0
344,4
219,3
335,7
338,0
286,3
163,0
372,0
2,7
0,0
10,0
0,0
206,6
69,9
83,5
341,9
219,0
335,0
338,3
286,5
164,0
373,0
2,7
0,0
9,6
0,0
206,6
70,0
83,3
339,5
218,8
334,4
338,2
286,8
165,0
374,0
2,6
0,0
9,6
0,0
206,5
69,6
82,3
337,1
219,2
333,6
338,0
287,3
166,0
375,0
2,6
0,0
9,4
0,0
206,2
70,2
82,1
335,0
219,0
332,9
338,0
286,9
167,0
376,0
2,6
0,0
9,3
0,0
205,9
69,8
81,6
332,4
219,5
332,0
337,2
287,6
168,0
377,0
2,6
0,0
9,3
0,0
205,4
69,8
84,0
330,5
219,7
331,1
336,9
287,8
169,0
378,0
2,6
0,0
9,3
0,0
204,7
70,1
84,8
327,8
220,4
330,5
336,3
288,4
170,0
379,0
2,5
0,0
9,3
0,0
204,2
69,9
83,2
326,1
220,1
329,7
335,5
288,6
171,0
380,0
2,5
0,0
9,3
0,0
203,9
70,0
83,6
323,8
220,6
328,9
334,7
288,7
172,0
381,0
2,5
0,0
9,2
0,0
202,9
70,6
82,6
321,3
220,3
328,2
333,9
289,4
173,0
382,0
2,4
0,0
9,2
0,0
202,3
70,2
82,4
319,8
221,0
327,3
333,3
289,7
174,0
383,0
2,4
0,0
9,1
0,0
201,7
69,8
81,7
318,1
221,0
326,7
332,7
290,2
175,0
384,0
2,4
0,0
8,9
0,0
201,3
69,7
83,2
316,4
221,4
326,0
332,0
290,6
176,0
385,0
2,4
0,0
9,0
0,0
200,5
70,5
85,0
314,0
222,4
325,4
331,3
290,9
177,0
386,0
2,4
0,0
9,0
0,0
200,0
70,4
83,2
312,2
221,9
324,9
330,4
291,5
178,0
387,0
2,4
0,0
8,9
0,0
199,1
70,3
83,4
310,4
221,7
324,2
329,5
291,8
179,0
388,0
2,4
0,0
8,7
0,0
198,6
69,9
82,3
308,7
221,8
323,7
328,5
292,3
180,0
389,0
2,4
0,0
8,8
0,0
197,9
70,4
82,1
307,1
222,4
323,2
328,0
292,2
181,0
390,0
2,3
0,0
8,7
0,0
197,6
69,9
81,2
305,5
221,8
322,6
326,8
292,9
182,0
391,0
2,3
0,0
9,1
0,0
196,3
70,2
82,4
303,8
222,6
322,1
325,8
293,1
183,0
392,0
2,3
0,0
9,2
0,0
195,1
70,6
84,8
302,0
222,6
321,4
325,0
293,1
184,0
393,0
2,3
0,0
9,1
0,0
193,6
70,4
83,0
300,5
223,0
320,6
323,9
294,0
185,0
394,0
2,3
0,0
9,2
0,0
192,4
69,7
82,9
298,7
223,3
320,2
323,1
294,3
186,0
395,0
2,2
0,0
9,2
0,0
191,6
70,2
82,2
297,4
222,0
319,7
322,1
295,1
187,0
396,0
2,3
0,0
9,3
0,0
190,6
69,5
81,3
296,2
222,0
319,4
321,3
295,6
188,0
397,0
2,2
0,0
9,2
0,0
189,9
69,6
81,3
295,0
221,8
319,1
320,3
296,2
189,0
398,0
2,2
0,0
9,2
0,0
188,9
70,1
82,0
293,5
222,4
318,7
319,4
296,6
190,0
399,0
2,2
0,0
9,1
0,0
187,7
70,1
84,4
292,1
222,4
318,3
318,7
297,4
191,0
400,0
2,2
0,0
9,1
0,0
187,0
70,3
83,0
290,6
222,5
318,0
318,0
297,9
192,0
401,0
2,1
0,0
9,0
0,0
186,4
69,9
82,5
289,6
221,8
317,6
317,1
298,2
193,0
402,0
2,1
0,0
9,2
0,0
185,9
69,9
82,8
288,5
221,6
317,2
316,3
299,1
194,0
403,0
2,1
0,0
9,1
0,0
185,5
69,9
81,7
286,9
221,5
316,9
315,6
299,5
195,0
404,0
2,1
0,0
8,9
0,0
185,3
69,9
81,7
286,0
221,1
316,6
314,4
300,4
196,0
405,0
2,1
0,0
9,0
0,0
185,2
69,9
82,4
284,6
220,9
316,2
313,7
300,9
197,0
406,0
2,1
0,0
9,1
0,0
184,6
70,0
84,5
283,7
220,2
315,9
313,0
301,3
198,0
407,0
2,1
0,0
9,1
0,0
184,0
70,3
82,7
283,0
220,6
315,6
312,3
302,2
199,0
408,0
2,0
0,0
9,0
0,0
183,9
69,6
82,4
281,5
220,4
315,1
311,8
302,6
200,0
409,0
2,0
0,0
9,0
0,0
183,5
69,6
82,1
280,9
219,8
314,8
311,0
303,2
201,0
410,0
2,0
0,0
9,0
0,0
183,3
69,8
81,2
279,9
220,0
314,6
310,0
303,9
202,0
411,0
2,0
0,0
9,0
0,0
182,9
70,1
80,8
279,5
220,2
314,1
309,8
303,8
203,0
412,0
2,0
0,0
9,2
0,0
183,0
70,2
80,4
278,6
219,7
313,6
309,4
304,3
204,0
413,0
2,0
0,0
9,2
0,0
182,5
70,0
83,3
278,2
219,7
313,3
308,8
304,6
205,0
414,0
2,0
0,0
9,1
0,0
182,2
70,4
82,9
277,8
219,6
313,0
307,7
305,5
206,0
415,0
2,0
0,0
9,2
0,0
182,2
70,0
82,5
276,9
220,0
312,7
307,2
305,8
Particulates Calculations
Page 2 of 4
DATA 2018-01-15 EPA PI 20162 RUN1 CAT1 MODEL GM 60
207,0
416,0
1,9
0,0
9,2
0,0
181,9
69,7
81,9
276,4
219,8
312,3
306,5
306,7
208,0
417,0
1,9
0,0
9,1
0,0
181,9
69,7
81,4
276,0
219,3
312,0
305,9
307,4
209,0
418,0
1,9
0,0
9,1
0,0
181,9
69,7
81,6
275,5
219,2
311,8
305,4
307,9
210,0
419,0
1,9
0,0
9,1
0,0
182,2
69,6
81,1
274,8
218,7
311,3
304,5
308,4
211,0
420,0
1,9
0,0
9,2
0,0
181,8
69,4
82,7
274,6
218,9
311,1
304,3
308,3
212,0
421,0
1,8
0,0
9,1
0,0
181,6
69,9
84,2
274,5
218,8
310,7
303,5
309,1
213,0
422,0
1,8
0,0
9,2
0,0
181,8
69,9
82,2
274,0
219,7
310,6
303,0
309,5
214,0
423,0
1,8
0,0
9,2
0,0
181,8
69,5
82,4
273,7
219,4
310,2
302,6
309,6
215,0
424,0
1,8
0,0
9,2
0,0
181,8
69,8
81,5
273,1
218,9
309,9
301,8
310,1
216,0
425,0
1,8
0,0
9,2
0,0
181,7
70,2
81,3
273,1
218,9
309,6
301,2
310,5
217,0
426,0
1,8
0,0
9,2
0,0
181,9
70,1
80,7
272,8
218,5
309,3
300,7
311,0
218,0
427,0
1,7
0,0
9,3
0,0
181,7
69,9
82,0
272,5
218,8
309,0
299,9
311,5
219,0
428,0
1,8
0,0
9,3
0,0
181,8
70,1
84,0
272,4
218,2
308,7
299,4
311,7
220,0
429,0
1,8
0,0
9,4
0,0
181,8
70,4
81,9
272,3
218,2
308,3
299,0
312,1
221,0
430,0
1,7
0,0
9,3
0,0
182,1
69,7
82,2
272,5
217,1
308,2
298,4
312,5
222,0
431,0
1,7
0,0
9,2
0,0
182,2
70,1
81,9
271,8
217,1
307,8
298,0
312,8
223,0
432,0
1,7
0,0
9,2
0,0
182,4
70,1
81,1
271,3
216,7
307,4
297,2
313,3
224,0
433,0
1,7
0,0
9,2
0,0
182,4
70,1
80,7
271,3
216,3
307,5
296,5
313,6
225,0
434,0
1,7
0,0
9,2
0,0
182,7
70,1
81,5
270,9
216,0
306,9
296,0
314,2
226,0
435,0
1,6
0,0
9,3
0,0
182,7
70,3
83,8
270,4
216,2
306,7
295,6
314,8
227,0
436,0
1,7
0,0
9,9
0,0
181,7
70,6
82,4
270,3
216,0
306,4
295,1
315,0
228,0
437,0
1,6
0,0
10,1
0,0
180,4
69,7
82,1
269,3
215,5
306,1
294,7
315,7
229,0
438,0
1,6
0,0
9,7
0,0
179,3
69,8
81,8
268,6
216,3
306,0
294,5
316,1
230,0
439,0
1,6
0,0
9,7
0,0
178,3
69,9
80,9
267,8
215,6
305,8
293,7
317,0
231,0
440,0
1,6
0,0
9,6
0,0
177,4
69,4
80,7
267,4
215,7
305,4
293,5
317,4
232,0
441,0
1,5
0,0
9,6
0,0
176,6
69,5
80,6
266,8
215,4
305,5
293,1
318,1
233,0
442,0
1,5
0,0
9,5
0,0
175,8
69,6
82,4
265,8
215,1
305,2
292,7
319,0
234,0
443,0
1,5
0,0
9,5
0,0
175,0
70,3
83,7
264,8
214,9
305,1
292,1
320,0
235,0
444,0
1,5
0,0
9,6
0,0
174,5
69,8
81,7
264,6
214,6
304,8
291,8
320,8
236,0
445,0
1,5
0,0
9,6
0,0
174,4
69,4
82,0
263,7
214,5
304,6
291,3
321,6
237,0
446,0
1,5
0,0
9,5
0,0
174,2
69,7
81,2
262,9
214,1
304,3
290,8
322,3
238,0
447,0
1,5
0,0
9,5
0,0
173,9
70,1
80,8
262,2
214,3
304,2
290,8
322,9
239,0
448,0
1,5
0,0
9,5
0,0
173,8
69,9
80,4
261,7
214,0
303,9
290,3
323,4
240,0
449,0
1,5
0,0
9,5
0,0
173,9
69,9
81,4
261,4
213,0
303,6
290,0
324,3
241,0
450,0
1,4
0,0
9,5
0,0
173,7
69,8
83,3
261,1
213,2
303,4
289,9
325,0
242,0
451,0
1,4
0,0
9,5
0,0
173,8
70,4
82,0
261,0
212,7
303,3
289,4
325,6
243,0
452,0
1,4
0,0
9,6
0,0
173,9
70,1
81,9
260,8
212,9
303,2
289,2
326,1
244,0
453,0
1,4
0,0
9,6
0,0
174,1
70,2
81,2
260,2
213,3
303,0
288,8
327,0
245,0
454,0
1,4
0,0
9,5
0,0
174,6
69,6
80,8
260,0
212,6
302,8
288,3
327,6
246,0
455,0
1,4
0,0
9,5
0,0
174,7
69,6
80,6
259,4
211,9
302,6
288,3
327,8
247,0
456,0
1,4
0,0
9,4
0,0
174,8
70,2
80,4
259,7
211,3
302,1
287,9
328,8
248,0
457,0
1,4
0,0
9,3
0,0
175,2
69,4
82,7
259,3
210,7
302,1
287,9
329,0
249,0
458,0
1,3
0,0
9,4
0,0
175,1
70,7
82,0
259,7
210,7
302,1
287,4
329,8
250,0
459,0
1,3
0,0
9,4
0,0
174,7
69,7
81,6
259,4
211,0
301,6
287,0
330,4
251,0
460,0
1,3
0,0
9,5
0,0
174,5
69,7
81,5
259,5
210,7
301,4
287,0
330,7
252,0
461,0
1,3
0,0
9,4
0,0
174,8
69,6
80,7
259,0
210,8
301,3
286,6
331,4
253,0
462,0
1,2
0,0
9,4
0,0
174,8
69,8
80,3
258,7
210,8
301,0
286,3
332,0
254,0
463,0
1,3
0,0
9,3
0,0
174,7
69,7
80,3
258,2
210,0
300,8
286,1
332,4
255,0
464,0
1,3
0,0
9,2
0,0
174,5
70,0
82,2
258,3
209,7
300,6
286,0
333,0
256,0
465,0
1,2
0,0
9,1
0,0
173,8
70,6
83,4
258,1
210,2
300,3
285,6
333,8
257,0
466,0
1,2
0,0
9,1
0,0
173,8
69,6
81,9
257,7
210,4
300,0
285,2
334,3
258,0
467,0
1,2
0,0
9,0
0,0
173,7
69,8
82,1
257,4
209,6
299,8
284,7
335,0
259,0
468,0
1,2
0,0
8,9
0,0
174,0
69,8
81,2
257,1
209,8
299,5
284,8
334,9
260,0
469,0
1,2
0,0
8,9
0,0
174,3
69,3
80,5
256,7
209,7
299,1
284,6
335,6
261,0
470,0
1,2
0,0
9,0
0,0
174,3
69,8
80,5
256,4
208,7
298,8
284,3
335,9
262,0
471,0
1,2
0,0
8,9
0,0
174,6
69,7
82,2
256,5
209,0
298,5
284,1
336,5
263,0
472,0
1,1
0,1
9,1
0,0
174,5
69,8
83,6
256,1
207,9
298,4
283,6
337,2
264,0
473,0
1,1
0,0
9,2
0,0
173,7
69,7
81,8
255,8
207,5
297,9
283,2
337,9
265,0
474,0
1,1
0,0
9,1
0,0
173,7
69,1
82,0
255,2
206,7
297,6
282,7
338,5
266,0
475,0
1,1
0,0
9,1
0,0
173,8
69,3
81,3
255,2
206,3
297,4
282,4
339,1
267,0
476,0
1,1
0,0
9,0
0,0
173,5
69,1
81,1
254,6
206,4
297,1
282,2
339,6
268,0
477,0
1,1
0,0
8,9
0,0
173,2
69,3
80,5
254,6
205,1
296,7
281,7
340,6
269,0
478,0
1,1
0,0
9,0
0,0
173,0
69,6
81,8
254,3
204,8
296,2
281,5
341,6
270,0
479,0
1,1
0,0
9,0
0,0
172,3
69,8
83,3
253,9
205,2
295,9
281,1
342,4
271,0
480,0
1,0
0,0
9,1
0,0
172,0
70,1
81,8
253,9
204,9
295,6
280,8
343,3
272,0
481,0
1,1
0,0
9,1
0,0
171,8
69,0
81,7
253,6
204,7
295,3
280,6
344,0
273,0
482,0
1,0
0,0
9,1
0,0
171,9
69,4
81,1
253,3
204,1
295,1
280,2
344,9
274,0
483,0
1,0
0,0
9,1
0,0
172,2
69,2
80,8
253,3
203,8
294,9
279,8
345,8
275,0
484,0
1,0
0,0
9,1
0,0
172,3
69,3
80,4
253,1
203,3
294,6
279,4
346,6
276,0
485,0
1,0
0,0
9,0
0,0
172,3
69,5
80,8
253,0
202,4
294,4
279,4
347,3
277,0
486,0
0,9
0,0
9,0
0,0
172,2
69,9
82,8
253,0
202,7
293,9
279,3
348,1
278,0
487,0
1,0
0,1
9,1
0,0
172,0
70,2
82,2
253,2
202,2
293,7
278,8
348,9
279,0
488,0
0,9
0,1
9,2
0,0
172,0
69,2
81,7
253,1
202,3
293,2
278,4
350,0
280,0
489,0
0,9
0,1
9,1
0,0
172,2
69,3
81,6
253,4
202,1
293,1
278,2
350,7
281,0
490,0
0,9
0,1
9,1
0,0
172,0
69,0
80,7
253,1
202,2
292,6
277,8
351,7
282,0
491,0
0,9
0,0
9,0
0,0
172,6
69,2
80,7
253,3
201,2
292,4
277,5
352,2
283,0
492,0
0,9
0,0
9,0
0,0
172,6
69,4
80,3
253,3
201,2
292,1
277,3
352,6
284,0
493,0
0,9
0,1
9,0
0,0
172,7
69,5
82,4
253,6
200,9
291,8
277,4
353,4
285,0
494,0
0,9
0,1
9,1
0,0
172,3
69,5
83,1
253,7
200,8
291,6
276,9
354,2
286,0
495,0
0,8
0,1
9,1
0,0
172,1
69,3
81,6
253,9
200,9
291,2
276,9
354,7
287,0
496,0
0,9
0,1
9,1
0,0
172,2
69,2
81,8
253,9
200,3
291,0
276,6
355,3
288,0
497,0
0,9
0,1
9,1
0,0
172,4
69,1
81,0
253,8
200,3
290,8
276,1
356,0
289,0
498,0
0,8
0,1
9,2
0,0
172,5
69,2
80,8
254,0
200,4
290,4
276,4
355,6
290,0
499,0
0,8
0,1
9,1
0,0
172,8
69,4
80,0
254,2
199,8
290,2
276,2
356,7
291,0
500,0
0,8
0,1
9,0
0,0
172,8
69,5
82,3
254,0
199,7
289,9
276,1
357,1
292,0
501,0
0,8
0,0
9,0
0,0
172,3
69,8
82,9
254,5
199,5
289,9
275,6
357,7
293,0
502,0
0,8
0,0
9,1
0,0
171,9
69,4
81,7
254,1
199,6
289,7
275,5
358,2
294,0
503,0
0,8
0,0
9,1
0,0
171,8
69,2
81,6
254,0
199,5
289,5
275,3
358,7
295,0
504,0
0,7
0,0
9,1
0,0
172,0
69,2
81,0
254,0
199,0
289,2
274,8
359,0
296,0
505,0
0,7
0,0
9,0
0,0
172,3
69,0
80,4
253,7
198,9
289,3
274,7
359,4
297,0
506,0
0,7
0,0
9,0
0,0
172,1
68,8
80,4
253,5
198,2
289,0
274,4
359,9
298,0
507,0
0,7
0,1
9,0
0,0
172,1
69,2
82,3
253,2
198,2
288,7
274,5
360,2
299,0
508,0
0,7
0,1
9,0
0,0
171,9
69,8
82,9
253,0
197,6
288,4
274,1
360,8
300,0
509,0
0,6
0,1
9,0
0,0
171,9
69,6
81,8
252,9
197,8
288,2
274,0
360,8
301,0
510,0
0,7
0,1
9,0
0,0
171,8
68,7
81,6
252,6
197,7
287,9
273,6
361,9
302,0
511,0
0,6
0,1
8,9
0,0
172,1
69,1
81,3
252,3
196,8
287,8
273,5
362,7
303,0
512,0
0,6
0,0
9,0
0,0
171,8
69,0
80,6
252,2
196,3
287,7
273,4
363,0
304,0
513,0
0,6
0,0
9,1
0,0
171,6
69,1
80,2
251,6
196,0
287,5
273,1
363,9
305,0
514,0
0,6
0,0
9,2
0,0
170,8
68,8
81,9
251,4
196,1
287,5
273,2
364,3
306,0
515,0
0,6
0,0
9,3
0,0
170,3
69,7
83,1
251,6
195,4
287,4
272,9
365,3
307,0
516,0
0,6
0,0
9,3
0,0
170,0
69,5
81,7
251,4
195,6
287,0
272,6
366,2
308,0
517,0
0,6
0,0
9,3
0,0
169,9
68,9
81,6
250,9
195,0
286,9
272,4
367,1
309,0
518,0
0,5
0,0
9,2
0,0
169,6
69,3
81,2
250,5
194,7
286,6
272,1
368,0
310,0
519,0
0,6
0,0
9,0
0,0
169,7
68,8
80,5
250,0
195,6
286,4
272,4
368,3
311,0
520,0
0,5
0,0
9,0
0,0
169,9
68,7
80,2
249,9
194,4
286,3
272,3
369,2
312,0
521,0
0,5
0,0
8,9
0,0
170,0
69,2
81,7
249,8
195,0
286,0
272,4
369,5
Particulates Calculations
Page 3 of 4
DATA 2018-01-15 EPA PI 20162 RUN1 CAT1 MODEL GM 60
313,0
522,0
0,5
0,0
9,0
0,0
169,7
69,7
83,5
249,8
194,1
285,9
271,9
370,6
314,0
523,0
0,5
0,0
9,1
0,0
169,2
69,4
81,7
249,7
194,0
285,6
272,0
371,6
315,0
524,0
0,5
0,0
9,2
0,0
168,6
68,8
81,7
249,6
194,0
285,4
271,9
372,3
316,0
525,0
0,5
0,0
9,1
0,0
168,0
69,2
81,2
249,3
193,8
285,4
271,3
373,4
317,0
526,0
0,5
0,0
9,0
0,0
167,5
68,8
80,7
248,7
193,9
285,1
271,6
374,2
318,0
527,0
0,4
0,0
8,9
0,0
167,1
68,8
80,2
248,6
193,2
285,0
271,2
375,4
319,0
528,0
0,4
0,0
8,9
0,0
166,8
69,2
81,7
247,9
193,3
284,6
271,1
376,0
320,0
529,0
0,4
0,0
8,9
0,0
166,0
69,5
83,1
247,5
193,0
284,3
270,9
377,2
321,0
530,0
0,4
0,0
8,9
0,0
165,5
69,4
81,5
247,0
192,9
284,1
270,5
378,6
322,0
531,0
0,4
0,0
8,9
0,0
164,8
69,0
81,5
246,9
192,5
283,9
270,5
379,8
323,0
532,0
0,4
0,0
8,8
0,0
164,8
69,3
81,1
246,3
193,2
283,6
270,1
381,1
324,0
533,0
0,4
0,0
8,9
0,0
164,2
68,9
80,6
246,0
192,3
283,3
270,2
382,3
325,0
534,0
0,3
0,0
8,9
0,0
164,3
68,8
80,3
245,7
192,0
283,2
269,9
383,6
326,0
535,0
0,3
0,0
9,0
0,0
164,1
69,0
80,8
245,1
191,7
282,9
269,9
384,5
327,0
536,0
0,3
0,0
9,0
0,0
163,7
69,1
82,8
245,0
191,2
282,6
270,0
385,7
328,0
537,0
0,3
0,0
9,0
0,0
163,1
69,5
81,5
244,5
191,3
282,5
269,6
387,1
329,0
538,0
0,3
0,0
9,0
0,0
162,7
68,9
81,3
244,3
190,6
282,1
269,5
388,4
330,0
539,0
0,3
0,0
9,1
0,0
162,7
68,9
81,1
243,9
190,7
282,0
269,0
389,7
331,0
540,0
0,3
0,0
9,1
0,0
162,7
68,9
80,6
243,7
190,9
281,7
269,1
390,6
332,0
541,0
0,3
0,0
9,1
0,0
162,5
68,9
79,9
243,6
190,9
281,5
268,9
391,7
333,0
542,0
0,2
0,0
9,0
0,0
162,4
69,4
80,5
243,8
190,4
281,2
268,9
392,3
334,0
543,0
0,3
0,0
9,1
0,0
162,8
69,1
82,6
243,5
189,7
281,1
268,9
393,1
335,0
544,0
0,2
0,0
9,1
0,0
162,6
69,8
81,8
243,7
189,6
280,9
268,5
394,2
336,0
545,0
0,2
0,0
9,2
0,0
162,8
69,0
81,2
243,5
189,3
280,5
268,7
394,8
337,0
546,0
0,2
0,0
9,1
0,0
162,6
69,2
81,1
243,5
188,8
280,4
268,2
395,8
338,0
547,0
0,2
0,0
9,1
0,0
162,4
68,9
80,5
243,6
188,8
280,0
268,2
396,6
339,0
548,0
0,2
0,0
9,1
0,0
162,6
68,6
80,1
243,3
188,5
279,8
268,2
397,3
340,0
549,0
0,2
0,0
9,1
0,0
163,1
68,6
80,8
243,8
188,4
279,7
268,3
397,2
341,0
550,0
0,2
0,0
9,0
0,0
163,0
69,5
82,5
243,7
188,4
279,2
268,3
397,9
342,0
551,0
0,2
0,0
8,9
0,0
163,0
69,0
81,7
243,2
188,4
279,1
267,8
398,7
343,0
552,0
0,1
0,0
8,9
0,0
162,9
68,6
81,1
243,4
187,6
278,6
267,8
399,2
344,0
553,0
0,1
0,0
8,9
0,0
162,9
69,3
81,1
243,3
187,3
278,5
267,5
399,9
345,0
554,0
0,1
0,0
8,9
0,0
163,1
68,6
80,5
243,3
187,2
278,2
267,5
400,3
346,0
555,0
0,1
0,0
8,9
0,0
163,7
68,6
80,2
243,1
186,9
278,0
267,4
400,6
347,0
556,0
0,1
0,1
9,0
0,0
163,7
68,9
80,6
243,0
186,7
277,5
267,4
400,7
348,0
557,0
0,1
0,1
9,1
0,0
163,9
68,9
82,5
243,0
186,1
277,4
267,6
400,9
349,0
558,0
0,1
0,1
9,1
0,0
163,8
69,0
81,9
243,4
186,0
277,1
267,2
401,6
350,0
559,0
0,1
0,1
9,1
0,0
164,2
68,7
81,3
244,0
186,1
276,7
267,3
401,8
351,0
560,0
0,1
0,1
9,1
0,0
165,0
69,2
81,1
244,1
186,1
276,6
267,0
402,2
352,0
561,0
0,1
0,1
9,1
0,0
165,4
68,7
80,4
244,8
186,4
276,1
267,4
402,1
353,0
562,0
0,1
0,1
9,1
0,0
165,8
68,9
79,6
245,3
186,0
275,7
267,2
402,2
354,0
563,0
0,0
0,1
9,0
0,0
166,4
68,9
80,6
245,6
186,0
275,3
267,2
402,0
Particulates Calculations
Page 4 of 4
DATA 2018-01-15 EPA PI 20162 RUN1 CAT1 MODEL GM 60
Manufacturer: HEARTHSTONE
Model:
GM 60
Overall Heating Efficiency:
80,42%
30,00
Run:
1
Combustion Efficiency:
99,50%
392,27
Project #:
PI 20162
Heat Transfer Efficiency:
80,83%
11,26
Test Duration: 354
min
HHV
LHV
Heat Output:
12 608 Btu/h
13 291 kJ/h
Eff
80,42%
86,92%
Heat Input:
15 676 Btu/h
16 526 kJ/h
Comb Eff
99,50%
99,50%
Ultimate CO2
HT Eff
80,83%
87,36%
CO2-ult
19,64
Burn Duration:
5,90
h
Output
13 291
kJ/h
F0
Burn Rate
0,83
kg/h
1,062
Burn Rate:
1,84
lb/h
0,834
kg/h
Grams CO
52
g
Input
16 526
kJ/h
Stack Temp:
225,8
Deg. F
107,7
Deg. C
MC wet
17,02
Air Fuel Ratio (A/F)
Dry Molecular Weight (Md)
Dry Moles Exhaust Gas (Nr):
Air Fuel Ratio (A/F)
Note: In the “Input data”, "Calc. % O2", "Fuel Properties", and
“Mass Balance” columns, [e], [d], [g], [a]. [b], [c], [h], [u], [w],
[j], and [k] refer to their respective variables in Clauses 13.7.3
CSA B415.1 OE Calculations
Page 1 of 1
DATA 2018-01-16 EPA PI 20162 RUN 2 CAT 2 MODEL GM 60
Paramètres
Tous les facteurs de corrections et autres paramètres qui peuvent être modifiés par
l’utilisateur du fichier sont regroupés ici.
Code verrouillage:
HEA
Description du test
Test standard
EPA
Run #
2
Date
16-01-2018
Technicien
M.M
Project #
PI 20162
Description de l'unité
Manufacturier
HEARTHSTONE
Modèle
GM 60
Combustion system
Cat
Appliance type
WOOD STOVE
Firebox volume
2,03
cu ft.
Appliance weight empty
N.A
lbs
Appliance weight full
N.A
lbs
Paramètres du test
Logging time
1
min
Manufacturer's rated heat output
BTU/h Donnée fournie par le manfacturier
Targeted category
4
Targeted output
N.A
BTU/h
Cp steel
N.A
BTU/lb-°F
Échantillonnage
Blank sampling rate
0,20
cuft/min
Internal probe diameter
0,18
in.
Calibration Factor (DGM #1):
0,988
Dimensionless
Equipment number (DGM #1):
EM 178
Calibration Factor (DGM #2):
0,988
Dimensionless
Equipment number (DGM #2):
EM 179
Calibration Factor (DGM #3):
0,986
Equipment number (DGM #3):
EM 070
Dimensionless
Tunnel
Targeted tunnel flow rate
170
scfm
Tunnel diameter
6
in.
Molecular weight
28,78
May be assumed to be 28,78 (EPA) Si B-415 = 29
Pitot tube type
Standard
Pitot tube coefficient
0,99
Dimensionless
Project nu. PI 20162
Date
16-01-2018
Technicien
M.M
Fuel data
Fuel type
Dimension
Fuel specie
D. Fir
HHV
19810,0 kJ/kg
D. Fir
Oak/Maple
%C
48,7
HHV
19 810
19 887
%H
6,9
%C
48,73
50
%O
43,9
%H
6,87
6,6
%Ash
0,5
%O
43,9
42,9
HHV
8519,2 Btu/lb
%Ash
0,5
0,5
LHV
7451,0 Btu/lb
HHV (Btu/lb)
8519
8552
LHV (Btu/lb)
7451
7480
Default Fuel Values
Paramètres
Page 1 of 1
DATA 2018-01-16 EPA PI 20162 RUN 2 CAT 2 MODEL GM 60
Preload data sheet
Lower
Ideal
Upper
12,79
14,21
15,63
Load Volume:
0,5185
cu. ft
Loading Density:
7,873
lbs./ft3
Number of Spaces:
Load Density (wet):
30,822
lbs./ft3
Spacer weight (lbs):
Dry Wood Density:
25,358353
Weight
Ave. MC x
Volume
Thick Wide x Length
lbs
Weight
Cubic Inches
2
4
8
1,086
22,6
21,8
21,3
21,4
21,8
23,65308
64,00
2
4
8
1,004
21,6
21,8
21,9
22,3
21,6
21,92736
64,00
2
4
8
1,124
22,3
22,4
22,8
22,4
22,6
25,29
64,00
2
4
8
1,026
21,8
21,6
21,9
22,3
22,9
22,6746
64,00
2
4
8
1,116
21
21,3
21,4
21,9
22,3
24,08328
64,00
2
4
8
1,144
22,3
22,4
21,9
21,8
22,3
25,32816
64,00
2
4
8
1,21
21,4
21,2
21
21,6
21,2
25,7488
64,00
2
4
8
1,17
21,3
22,4
22,3
22
22,4
25,8336
64,00
2
4
8
1,168
22,4
22,8
22,4
22,6
22,6
26,35008
64,00
2
4
8
1,202
23,1
23
23,6
22,8
22,4
27,62196
64,00
2
4
8
1,096
21,9
21,4
21,3
21,5
21,2
23,52016
64,00
2
4
8
1,326
20,8
20,4
20,9
20,4
20,5
27,3156
64,00
2
4
8
1,112
19,6
19,1
19,2
19,6
19,8
21,63952
64,00
2
4
8
1,198
19,4
19,8
19,3
19,3
19,8
23,38496
64,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
SUM MCx 344,37116
PreTest Load Weight:
15,98
lbs.
Dry Weight:
5,96
kg.
Average Moisture Content: %
Dry:
21,55
21,55
Wet:
17,73
Must be 18-28
must be 15,2-22
Project nu. PI 20162
Date
16-01-2018
Technicien
M.M
Test Load Weight:
Piece Size (in):
Meter Moisture Content
Dry Uncorrected %
Preload Data
Page 1 of 1
Confidentiel
06/02/2018
Page 1
FUEL LOAD DATA SHEET, CSA B415
Lower
Ideal
Upper
12,8
14,2
15,6
* For boilers, a loading density factor of 10 lb/ft3 is applied
Load Volume:
0,43
cu. ft
Loading Density:
6,5
lbs./ft3
Number of Spaces:
12
Load Density (wet):
30,7
lbs./ft3
Spacer weight:
lbs
Dry Wood Density:
25,5
lbs./ft3
Weight
Ave. MC x
Volume
Ave. MC
Thick Wide xLength
lbs
Weight
Cubic Inches
%
1,5
3,5
17,5
1,91
21,80
20,20
21,60
21,30
20,90
40,3098
91,88
21,2
1,5
3,5
17,5
1,96
19,80
19,60
19,90
19,30
20,80
38,88528
91,88
19,9
3,5
3,5
17,5
4,05
21,10
21,30
20,80
20,00
20,60
84,16104
214,38
20,8
3,5
3,5
17,5
4,11
20,10
20,60
19,30
21,10
20,90
83,8032
214,38
20,4
1,5
0,75
5
0,10
20,60
2,1424
5,63
20,6
1,5
0,75
5
0,10
20,30
2,03
5,63
20,3
1,5
0,75
5
0,10
20,40
2,0808
5,63
20,4
1,5
0,75
5
0,10
20,80
2,08
5,63
20,8
1,5
0,75
5
0,10
20,90
2,0482
5,63
20,9
1,5
0,75
5
0,12
21,00
2,52
5,63
21,0
1,5
0,75
5
0,10
21,30
2,1726
5,63
21,3
1,5
0,75
5
0,09
21,80
2,0492
5,63
21,8
1,5
0,75
5
0,10
22,10
2,1216
5,63
22,1
1,5
0,75
5
0,11
21,80
2,3544
5,63
21,8
1,5
0,75
5
0,10
21,60
2,16
5,63
21,6
1,5
0,75
5
0,14
21,30
3,0672
5,63
21,3
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
SUM MCx 273,98572
21,0 %
Test Load Weight:
13,29
lbs.
Dry Weight:
5,00
kg.
Average Moisture Content: %
Dry:
20,61
Dry(EPA)
20,61
20,61
Wet:
17,09
Dry(B415
20,61
Must be 19-25
must be 15,2-22
Coal Bed Range:
2,7
lbs. to
3,3
lbs.
TEST CHARGE:
Project nu. PI 20162
Coal bed weight:
2,6
lbs.
Date
16-01-2018
Technicien
M.M
Test Load Weight:
Piece Size (in):
Meter Moisture Content
Dry Uncorrected %
Load Data
Page 1 of 1
DATA 2018-01-16 EPA PI 20162 RUN 2 CAT 2 MODEL GM 60
Filter set weight
Ambient
blank (g)
Date
Heure
probe
front
back
gasket
probe
front
back
gasket
probe
front
back
gasket
Filter
Number
1
14
15
24
3
16
17
25
6
18
19
26
20
Before (1)
Before (2)
Before (3)
Before (4)
Before (5)
61,0690
0,1270
0,1266
34,4169
61,4563
0,1263
0,1282
34,9448
61,3760
0,1294
0,1290
35,5631
0,1256
15/01/2018
17:00
Before (6)
61,0689
0,1270
0,1265
34,4169
61,4563
0,1264
0,1281
34,9449
61,3759
0,1293
0,1289
35,5632
0,1256
16/01/2018
09:30
After (1)
61,0692
0,1257
0,1261
34,6202
61,4568
0,1261
0,1281
34,9462
61,3765
0,1288
0,1284
35,5659
0,1257
16/01/2018
16:00
After (2)
61,0689
0,1252
0,1258
34,4194
61,4565
0,1258
0,1279
34,9458
61,3760
0,1285
0,1281
35,5655
0,1256
29/01/2018
08:00
After (3)
61,0690
0,1253
0,1259
34,4195
61,4565
0,1259
0,1279
34,9458
61,3760
0,1285
0,1281
35,5655
0,1256
01/02/2018
08:00
After (4)
61,0690
0,1253
0,1259
34,4195
61,4565
0,1259
0,1279
34,9458
61,3760
0,1285
0,1281
35,5655
0,1256
05/02/2018
08:00
After (5)
After (6)
61,0690
0,1253
0,1259
34,4195
61,4565
0,1259
0,1279
34,9458
61,3760
0,1285
0,1281
35,5655
0,1256
05/02/2018
08:00
Difference
0,0001
-0,0017
-0,0006
0,0026
0,0002
-0,0005
-0,0002
0,0009
0,0001
-0,0008
-0,0008
0,0023
0,0000
Total (mg)
0,4
0,8
0,8
0
Total ajusté (mg)
0,40
0,80
0,80
Project nu. PI 20162
Date
16-01-2018
Technicien
System 2 (g)
System 1 (g) 1st hour
System 1 (g)
Filter set weight
Page 1 of 1
DATA 2018-01-16 EPA PI 20162 RUN 2 CAT 2 MODEL GM 60
SFBA EPA EMISSION RESULTS
RESULTS
Average emission rate:
0,2
g/hr
Burn Rate :
1,239
Dry kg/hr
Test Duration:
242
min
PRESSURE FACTOR:
DGM 1
0,98715
BAROMETRIC PRESSURE
DGM 2
0,98609
Average:
30,312534 in Hg
DGM 3
1,01312
Start:
30,327299 in Hg
End:
30,297769 in Hg
TEMPERATURE FACTORS
DGM 1
0,98576
DGM 2
0,98457
DGM CONTROLLER VALUES
DGM 3
0,99335
DGM 1
Final: 21894,370
Cuft
Initial: 21850,478
Cuft
VOLUMES SAMPLED
DGM 1
42,193
SCft
DGM 2
Final: 19283,875
Cuft
DGM 2
42,845
Scft
Initial: 19239,228
Cuft
DGM 3
36,392
SCft
DGM #3
Final:
686,900
Cuft
Initial:
650,240
Cuft
TOTAL TUNNEL VOLUME :
42673
TEMPERATURES
SAMPLE RATIOS
DGM 1
535,627
°R
Sample Train 1:
1011,392
DGM 2
536,274
°R
Sample Train 2:
996,000
CALIBRATION FACTORS
Paticulate concentration
DGM 1
0,9879
Sample Train 1
0,000019
g/dscf
DGM 2
0,9884
Sample Train 2
0,000019
g/dscf
DGM #3
0,9864
Room
0,000000
g/dscf
TUNNEL FLOW RATE:
176,336
Dscfm
TOTAL EMISSIONS
PARTICULATE CATCH
Sample Train 1
0,81
g
Total Sample Train 1:
0,80 mg
Sample Train 2
0,80
g
Total Sample Train 2:
0,80 mg
Total Sample Train 1 1st hour:
0,40 mg
EMISSION RATES
Sample Train 1
0,20
g/hr
Sample Train 2
0,20
g/hr
1st hour emission rate
0,40
g/hr
DEVIATION:
0,77%
Train 1
Train 2
Cs
1,896E-05
1,86721E-05
Particulates Calculations
Page 1 of 1
DATA 2018-01-16 EPA PI 20162 RUN 2 CAT 2 MODEL GM 60
Average
0,12
10,65
#DIV/0!
287,90
71,54
87,59
392,63
255,89
382,56
372,89
427,87
*****
*1
*2
*3
*4
*5
*6
*7
*8
Elapsed
Weight
Flue
Room
Tunnel
Unit
Unit
Unit
Unit
Unit
Time
Raw data row
Remaining
CO
CO2
O2
Gas
Temp
Dry Bulb
Top
Back
R.Side
L.Side
Bottom
min
lbs
%%%
°F
°F
°F
°F
°F
°F
°F
°F
0,00
173,00
13,3
0,1
1,1
0,0
281,7
70,8
125,8
336,2
253,5
371,0
368,3
565,3
1,0
174,0
13,2
0,3
2,0
0,0
297,1
71,0
98,9
331,3
251,9
369,6
366,2
560,4
2,0
175,0
13,0
0,0
5,8
0,0
324,9
71,2
99,1
331,4
251,8
368,1
364,2
555,7
3,0
176,0
12,8
0,1
9,9
0,0
357,1
70,8
101,5
341,1
251,9
366,5
362,8
550,8
4,0
177,0
12,6
0,1
12,7
0,0
392,5
70,8
104,0
355,8
250,4
365,1
361,3
545,4
5,0
178,0
12,5
0,6
14,8
0,0
370,6
70,8
94,9
371,7
249,7
363,7
360,2
544,3
6,0
179,0
12,4
0,1
9,8
0,0
344,0
70,9
91,7
376,3
248,8
362,7
359,2
541,4
7,0
180,0
12,4
0,0
7,4
0,0
325,5
71,3
91,1
377,9
246,7
361,3
358,2
537,8
8,0
181,0
12,3
0,0
6,7
0,0
315,1
71,9
90,6
377,3
245,3
359,7
356,9
534,7
9,0
182,0
12,2
0,0
8,0
0,0
309,9
71,0
90,4
378,0
244,2
358,0
355,5
530,9
10,0
183,0
12,1
0,0
9,8
0,0
307,0
70,8
90,2
379,4
242,5
356,5
354,0
528,4
11,0
184,0
12,0
0,0
10,6
0,0
305,5
70,9
90,3
381,5
241,6
354,8
352,5
525,0
12,0
185,0
11,9
0,0
10,8
0,0
306,0
70,4
90,1
382,6
240,2
353,1
351,2
521,3
13,0
186,0
11,8
0,0
10,1
0,0
307,8
70,8
89,9
383,0
239,9
351,9
349,9
518,1
14,0
187,0
11,6
0,0
10,5
0,0
311,5
70,6
90,4
384,5
239,0
350,1
348,9
513,5
15,0
188,0
11,5
0,1
12,6
0,0
316,2
70,6
91,4
387,9
237,2
349,0
347,8
509,8
16,0
189,0
11,4
0,1
13,1
0,0
322,6
71,7
91,6
390,8
235,3
348,0
347,2
505,6
17,0
190,0
11,3
0,1
13,5
0,0
328,4
70,9
91,9
395,5
234,9
347,1
346,4
502,0
18,0
191,0
11,1
0,1
14,1
0,0
334,7
71,0
92,2
401,1
234,5
346,5
345,9
498,6
19,0
192,0
11,0
0,1
14,4
0,0
339,7
71,4
92,2
406,8
233,6
346,5
345,6
494,9
20,0
193,0
10,9
0,1
14,5
0,0
343,2
70,7
92,2
412,7
233,5
345,9
345,3
491,0
21,0
194,0
10,7
0,1
14,4
0,0
345,1
71,0
92,1
417,9
232,7
346,0
345,1
487,0
22,0
195,0
10,6
0,1
14,3
0,0
346,8
70,9
92,4
423,3
231,7
346,0
345,2
483,9
23,0
196,0
10,5
0,1
14,4
0,0
347,2
71,4
92,1
428,4
231,7
346,4
345,2
480,9
24,0
197,0
10,3
0,1
14,7
0,0
347,7
71,1
93,0
432,9
231,9
347,1
345,4
476,8
25,0
198,0
10,2
0,1
15,0
0,0
349,8
71,6
92,9
437,3
232,4
348,1
346,0
474,2
26,0
199,0
10,0
0,1
15,0
0,0
351,2
71,4
93,2
441,8
232,9
348,6
346,7
470,2
27,0
200,0
9,9
0,1
15,1
0,0
352,9
71,3
93,0
445,1
234,5
349,7
347,4
467,8
28,0
201,0
9,8
0,2
15,2
0,0
354,5
71,1
93,1
450,0
235,2
350,8
348,2
465,4
29,0
202,0
9,7
0,3
15,3
0,0
355,7
70,6
93,3
454,7
235,3
352,0
349,3
462,8
30,0
203,0
9,5
0,3
15,4
0,0
356,1
71,2
92,9
458,5
236,0
353,5
350,1
459,7
31,0
204,0
9,4
0,3
15,4
0,0
356,5
71,5
93,0
462,8
236,3
355,2
351,3
457,4
32,0
205,0
9,3
0,2
15,3
0,0
356,6
71,6
93,1
466,5
238,8
356,9
352,5
454,4
33,0
206,0
9,2
0,2
15,2
0,0
356,0
72,0
93,7
470,9
239,9
358,6
354,0
451,6
34,0
207,0
9,1
0,1
15,0
0,0
354,7
71,9
93,4
474,0
239,3
360,3
355,2
449,3
35,0
208,0
8,9
0,1
14,9
0,0
354,1
71,4
93,5
475,8
241,0
362,3
356,4
446,9
36,0
209,0
8,8
0,2
15,1
0,0
354,8
71,5
93,4
478,5
242,5
364,1
358,0
444,8
37,0
210,0
8,7
0,3
15,3
0,0
355,7
71,5
93,6
480,8
243,3
366,0
359,2
442,4
38,0
211,0
8,5
0,4
15,4
0,0
357,0
71,3
93,6
484,3
244,6
367,8
360,7
440,3
39,0
212,0
8,4
0,7
15,5
0,0
358,4
71,6
93,5
488,1
246,0
369,8
362,1
438,6
40,0
213,0
8,3
1,0
15,4
0,0
358,9
70,9
93,4
491,8
247,1
371,9
363,4
435,9
41,0
214,0
8,1
0,9
15,5
0,0
358,5
71,5
93,9
495,3
247,9
373,8
365,1
433,7
42,0
215,0
8,0
0,8
15,5
0,0
358,9
72,3
93,9
499,1
249,4
376,2
366,8
430,9
43,0
216,0
7,9
0,6
15,6
0,0
358,5
71,8
93,9
501,4
250,8
378,4
368,4
428,6
44,0
217,0
7,8
0,5
15,6
0,0
358,2
71,2
94,0
504,1
252,2
380,5
369,9
426,5
45,0
218,0
7,6
0,3
15,6
0,0
358,9
71,6
94,1
506,1
253,4
382,5
371,7
424,5
46,0
219,0
7,5
0,4
15,6
0,0
359,3
71,4
93,9
507,9
253,9
384,7
373,4
422,3
47,0
220,0
7,4
0,4
15,5
0,0
358,9
71,6
93,6
509,0
256,0
387,0
375,0
420,4
48,0
221,0
7,3
0,3
15,5
0,0
357,6
71,4
93,4
510,9
256,1
389,1
376,8
417,8
49,0
222,0
7,2
0,3
15,4
0,0
356,8
71,6
93,3
511,1
257,6
391,1
378,2
415,6
50,0
223,0
7,0
0,2
15,5
0,0
356,8
71,5
93,5
513,5
258,9
393,5
380,0
413,4
51,0
224,0
7,0
0,1
15,3
0,0
356,2
72,1
93,5
514,1
259,6
395,6
381,7
410,7
52,0
225,0
6,8
0,1
15,2
0,0
354,6
71,8
93,5
515,6
262,1
398,0
383,5
408,6
53,0
226,0
6,7
0,1
15,0
0,0
352,8
71,7
93,4
515,5
262,0
400,0
384,7
406,7
54,0
227,0
6,6
0,0
14,8
0,0
351,3
71,9
93,1
514,7
262,6
402,4
386,7
404,3
55,0
228,0
6,6
0,1
14,8
0,0
350,1
71,7
92,9
514,7
263,6
404,2
388,1
403,1
56,0
229,0
6,4
0,1
14,8
0,0
349,8
71,6
93,1
514,1
264,6
406,1
389,3
400,7
57,0
230,0
6,3
0,1
14,8
0,0
348,4
71,4
92,8
512,8
265,2
407,8
390,4
398,9
58,0
231,0
6,2
0,1
14,8
0,0
348,0
71,6
92,3
511,9
265,2
409,7
391,6
397,4
59,0
232,0
6,1
0,2
14,8
0,0
347,9
71,6
93,2
510,9
266,4
411,6
393,1
395,4
60,0
233,0
6,0
0,3
14,7
0,0
347,3
72,6
93,2
509,9
266,7
413,5
394,5
393,7
61,0
234,0
5,9
0,4
14,7
0,0
346,7
71,3
93,3
510,3
268,2
415,1
395,7
391,8
62,0
235,0
5,8
0,5
14,7
0,0
346,8
71,8
93,0
508,5
268,1
416,7
396,7
390,6
63,0
236,0
5,7
0,5
14,7
0,0
346,8
71,8
93,0
507,8
269,4
418,1
397,8
389,0
64,0
237,0
5,6
0,4
14,7
0,0
346,4
71,1
92,9
507,7
269,4
419,6
398,7
387,6
65,0
238,0
5,5
0,5
14,5
0,0
345,4
71,7
92,6
507,5
269,9
421,0
400,0
386,4
66,0
239,0
5,4
0,4
14,8
0,0
344,6
71,4
92,4
507,3
270,5
422,4
400,9
385,0
67,0
240,0
5,3
0,4
14,8
0,0
344,1
71,5
92,2
506,6
271,1
424,0
402,1
383,7
68,0
241,0
5,2
0,5
14,8
0,0
342,9
71,5
92,5
507,2
271,7
425,5
403,2
382,5
69,0
242,0
5,1
0,5
14,8
0,0
342,1
72,7
92,6
507,1
271,5
427,0
404,8
381,1
70,0
243,0
5,0
0,5
14,8
0,0
341,6
71,8
92,5
507,4
273,3
428,3
405,8
380,2
71,0
244,0
4,9
0,5
14,8
0,0
341,3
71,3
92,4
506,9
272,1
429,7
407,0
379,4
72,0
245,0
4,8
0,4
14,7
0,0
340,5
72,1
92,4
506,9
273,5
430,6
408,3
378,8
73,0
246,0
4,7
0,4
14,8
0,0
339,2
71,6
92,2
506,2
273,7
432,0
409,4
377,9
74,0
247,0
4,6
0,4
14,7
0,0
338,2
72,0
92,1
506,3
273,9
433,0
410,5
377,2
75,0
248,0
4,6
0,4
14,7
0,0
337,4
71,6
91,8
505,2
274,9
433,9
411,5
376,3
76,0
249,0
4,4
0,4
14,6
0,0
336,7
71,4
91,6
505,9
275,7
435,0
412,8
375,7
77,0
250,0
4,3
0,4
14,7
0,0
335,7
72,0
91,4
505,4
275,1
436,4
413,7
375,5
78,0
251,0
4,2
0,4
14,6
0,0
334,6
72,0
91,8
505,6
275,3
437,5
415,0
374,3
79,0
252,0
4,2
0,3
14,5
0,0
332,0
72,6
91,8
504,1
276,0
438,7
416,2
374,1
80,0
253,0
4,1
0,3
14,2
0,0
330,7
72,2
91,7
503,6
277,2
439,3
416,9
373,5
81,0
254,0
4,0
0,3
14,1
0,0
329,2
71,8
91,2
501,5
277,8
440,1
418,1
373,1
82,0
255,0
3,9
0,2
13,9
0,0
327,8
72,0
91,2
500,1
278,5
440,8
419,3
372,8
83,0
256,0
3,9
0,1
13,8
0,0
325,9
71,8
90,7
499,3
279,4
441,4
420,4
372,4
84,0
257,0
3,8
0,1
13,7
0,0
323,8
72,0
90,5
496,2
280,2
442,1
421,2
372,0
85,0
258,0
3,7
0,0
13,6
0,0
321,9
71,5
90,4
494,5
280,2
442,4
421,9
371,6
86,0
259,0
3,7
0,0
13,5
0,0
320,0
71,9
90,0
491,5
280,2
442,5
422,5
371,5
87,0
260,0
3,6
0,0
13,3
0,0
317,8
71,7
90,3
488,7
280,8
442,9
423,7
371,1
88,0
261,0
3,5
0,0
13,2
0,0
315,3
73,1
90,1
486,7
281,3
443,2
424,6
370,6
89,0
262,0
3,4
0,0
13,2
0,0
312,8
72,3
90,2
484,7
282,9
443,5
425,2
370,4
90,0
263,0
3,4
0,0
13,1
0,0
311,0
72,1
90,1
481,7
282,8
443,6
425,9
370,7
91,0
264,0
3,3
0,0
13,1
0,0
309,4
71,9
89,8
479,3
283,2
443,6
426,3
370,1
92,0
265,0
3,2
0,0
13,0
0,0
308,0
71,8
89,7
477,4
283,7
443,4
426,7
370,1
93,0
266,0
3,2
0,0
13,2
0,0
307,3
72,0
89,4
475,5
284,4
443,4
427,3
369,9
94,0
267,0
3,1
0,0
13,5
0,0
306,1
72,2
89,2
474,4
285,2
443,2
427,7
369,8
95,0
268,0
3,0
0,0
13,5
0,0
304,8
71,9
89,1
473,7
286,2
443,4
428,6
369,8
96,0
269,0
3,0
0,0
13,2
0,0
303,1
72,5
88,9
471,7
285,5
443,9
428,8
369,9
97,0
270,0
2,9
0,0
12,8
0,0
301,0
72,3
88,9
469,0
286,9
443,8
429,5
369,4
98,0
271,0
2,9
0,0
12,2
0,0
298,6
72,6
89,1
466,7
286,8
444,1
429,7
369,8
99,0
272,0
2,8
0,0
12,1
0,0
296,7
71,9
88,7
463,4
287,1
444,0
429,8
369,5
100,0
273,0
2,8
0,0
11,9
0,0
294,8
72,2
88,5
460,5
288,3
443,6
430,1
369,9
Particulates Calculations
Page 1 of 3
DATA 2018-01-16 EPA PI 20162 RUN 2 CAT 2 MODEL GM 60
101,0
274,0
2,7
0,0
11,9
0,0
293,1
72,0
88,3
457,2
288,8
443,5
429,8
370,0
102,0
275,0
2,7
0,0
11,7
0,0
290,6
72,5
87,9
454,6
289,7
443,5
429,7
370,0
103,0
276,0
2,6
0,0
11,2
0,0
288,4
72,0
87,6
450,8
289,6
443,0
429,8
370,4
104,0
277,0
2,6
0,0
10,7
0,0
286,3
71,9
87,1
446,8
289,8
442,6
429,7
370,2
105,0
278,0
2,6
0,0
10,3
0,0
283,8
72,3
87,2
442,5
290,2
442,4
429,3
370,4
106,0
279,0
2,6
0,0
10,1
0,0
282,3
71,5
87,3
438,2
290,2
441,7
428,9
370,7
107,0
280,0
2,5
0,0
9,8
0,0
280,2
72,9
86,9
434,1
289,9
441,1
428,8
370,4
108,0
281,0
2,5
0,0
9,8
0,0
278,5
71,7
87,1
430,0
290,4
440,2
427,7
370,9
109,0
282,0
2,5
0,0
9,8
0,0
276,2
72,3
86,6
425,8
290,5
439,1
426,7
371,8
110,0
283,0
2,5
0,0
9,9
0,0
274,5
72,1
86,7
421,8
291,5
438,0
426,0
372,4
111,0
284,0
2,4
0,0
9,9
0,0
272,6
72,2
86,4
418,4
290,3
437,0
424,6
373,2
112,0
285,0
2,4
0,0
9,9
0,0
271,9
71,7
86,2
414,9
291,5
435,8
423,7
373,8
113,0
286,0
2,4
0,0
10,4
0,0
270,5
71,6
86,2
411,3
290,1
434,6
422,4
374,7
114,0
287,0
2,3
0,0
10,2
0,0
269,6
71,9
86,0
408,3
290,2
433,4
421,1
375,7
115,0
288,0
2,3
0,0
10,1
0,0
269,3
72,0
86,0
405,3
290,1
432,8
419,9
376,8
116,0
289,0
2,3
0,0
10,1
0,0
268,6
72,1
86,1
402,1
290,0
431,5
418,9
377,8
117,0
290,0
2,2
0,0
10,0
0,0
267,7
72,4
86,1
399,9
289,4
430,5
417,6
379,7
118,0
291,0
2,2
0,0
9,9
0,0
266,8
71,9
85,9
397,1
289,0
429,4
416,0
381,0
119,0
292,0
2,2
0,0
9,9
0,0
266,4
72,2
85,8
395,2
288,5
428,2
414,9
382,7
120,0
293,0
2,2
0,0
9,9
0,0
265,2
71,8
85,6
392,2
287,9
427,0
413,6
384,1
121,0
294,0
2,1
0,0
9,8
0,0
264,3
71,9
85,2
390,2
287,7
425,8
412,3
385,3
122,0
295,0
2,1
0,0
9,8
0,0
263,9
71,4
85,3
387,8
286,9
424,5
411,1
386,7
123,0
296,0
2,1
0,0
9,9
0,0
263,4
71,8
85,2
385,7
286,1
423,3
409,9
388,5
124,0
297,0
2,1
0,0
9,8
0,0
262,5
72,2
84,9
383,5
286,5
422,1
408,7
390,2
125,0
298,0
2,1
0,0
9,8
0,0
262,1
71,9
85,7
381,8
286,1
421,0
407,4
391,5
126,0
299,0
2,1
0,0
9,7
0,0
261,0
72,6
85,3
379,6
285,0
419,4
406,5
392,9
127,0
300,0
2,0
0,0
9,8
0,0
260,1
71,7
85,2
378,1
284,6
418,4
405,0
394,8
128,0
301,0
2,0
0,0
9,8
0,0
259,7
71,7
85,0
375,1
283,6
417,2
404,0
396,1
129,0
302,0
1,9
0,0
9,7
0,0
258,6
72,1
84,8
373,2
282,5
415,8
402,8
397,7
130,0
303,0
1,9
0,0
9,7
0,0
257,8
71,8
84,7
371,6
281,4
415,0
401,7
399,0
131,0
304,0
1,9
0,0
9,7
0,0
257,2
71,6
84,7
369,4
279,8
413,6
400,4
400,3
132,0
305,0
1,9
0,0
9,8
0,0
256,9
71,7
84,6
367,6
279,0
412,2
399,2
402,1
133,0
306,0
1,9
0,0
9,7
0,0
256,1
71,5
84,2
365,4
277,8
411,1
397,7
403,8
134,0
307,0
1,9
0,0
9,7
0,0
255,5
72,2
84,7
363,4
277,4
409,9
396,4
404,9
135,0
308,0
1,8
0,0
9,7
0,0
255,0
72,5
84,6
361,5
276,9
408,7
395,6
406,1
136,0
309,0
1,8
0,0
9,7
0,0
254,0
71,8
84,8
360,2
275,3
408,0
394,5
407,9
137,0
310,0
1,8
0,0
9,7
0,0
253,5
72,1
84,3
358,6
275,4
406,5
393,2
408,7
138,0
311,0
1,7
0,0
9,7
0,0
252,7
72,5
84,3
356,6
274,7
405,6
392,5
410,6
139,0
312,0
1,8
0,0
9,7
0,0
251,7
71,8
84,3
355,8
274,9
404,4
391,2
411,7
140,0
313,0
1,7
0,0
9,3
0,0
251,7
71,6
84,2
354,4
273,9
403,3
389,9
413,3
141,0
314,0
1,7
0,0
8,8
0,0
251,7
71,8
84,1
352,8
273,5
402,4
388,8
414,6
142,0
315,0
1,7
0,0
8,6
0,0
252,1
72,0
84,0
351,4
273,3
401,4
387,7
415,3
143,0
316,0
1,7
0,0
8,3
0,0
252,2
71,2
83,9
350,2
272,2
400,3
386,7
415,7
144,0
317,0
1,6
0,1
8,2
0,0
253,2
72,0
84,7
348,7
272,5
399,2
385,7
415,6
145,0
318,0
1,6
0,1
8,1
0,0
253,2
72,3
84,4
347,6
272,1
398,1
384,6
415,3
146,0
319,0
1,6
0,1
8,3
0,0
253,0
72,1
84,3
346,9
271,8
396,9
383,3
415,3
147,0
320,0
1,6
0,1
8,3
0,0
253,6
71,8
84,3
345,4
271,5
395,7
381,9
415,5
148,0
321,0
1,6
0,1
8,5
0,0
254,1
71,7
84,2
344,4
271,0
394,4
380,8
415,4
149,0
322,0
1,6
0,1
8,7
0,0
254,1
71,7
84,0
343,4
269,6
393,3
379,7
415,9
150,0
323,0
1,5
0,1
8,8
0,0
253,7
71,5
83,8
342,8
269,0
391,9
378,6
416,3
151,0
324,0
1,5
0,1
8,6
0,0
253,1
71,5
83,7
341,7
267,6
390,6
377,1
416,6
152,0
325,0
1,5
0,1
8,7
0,0
253,3
71,9
83,7
340,8
267,0
389,3
376,1
416,7
153,0
326,0
1,5
0,1
8,7
0,0
253,2
71,7
84,0
340,1
265,8
388,2
374,9
417,6
154,0
327,0
1,5
0,1
8,8
0,0
252,8
72,2
84,1
339,5
265,3
387,0
374,3
417,5
155,0
328,0
1,4
0,1
8,9
0,0
252,1
71,8
84,3
338,9
264,1
386,0
373,2
418,2
156,0
329,0
1,4
0,1
8,9
0,0
252,2
71,8
84,0
337,9
262,9
384,6
372,1
419,0
157,0
330,0
1,4
0,1
9,0
0,0
251,8
71,7
84,1
337,6
261,7
383,6
371,3
419,9
158,0
331,0
1,4
0,1
9,0
0,0
251,2
71,2
83,8
336,7
261,1
382,4
370,2
421,3
159,0
332,0
1,3
0,1
8,9
0,0
250,8
71,7
83,6
335,8
259,7
381,3
369,3
422,6
160,0
333,0
1,3
0,1
8,8
0,0
251,0
71,4
83,4
335,0
259,3
380,4
368,2
423,7
161,0
334,0
1,3
0,1
8,7
0,0
251,1
71,9
83,4
334,4
257,9
379,7
367,4
425,0
162,0
335,0
1,3
0,1
8,6
0,0
251,1
71,6
83,2
333,8
257,1
378,7
366,7
426,2
163,0
336,0
1,3
0,1
8,6
0,0
251,0
71,7
84,3
333,2
256,4
377,7
365,4
427,6
164,0
337,0
1,3
0,1
8,5
0,0
251,1
72,3
84,0
332,5
255,7
376,3
364,8
428,4
165,0
338,0
1,2
0,1
8,6
0,0
250,9
71,7
83,8
332,1
254,8
375,4
363,8
429,2
166,0
339,0
1,2
0,1
8,5
0,0
250,8
71,5
83,6
331,4
254,6
374,6
363,2
430,9
167,0
340,0
1,2
0,1
8,5
0,0
250,8
71,4
83,5
330,9
253,9
373,5
362,5
432,0
168,0
341,0
1,2
0,1
8,4
0,0
250,9
71,4
83,4
330,6
252,9
372,6
361,6
432,9
169,0
342,0
1,2
0,1
8,4
0,0
251,1
71,7
83,1
330,0
252,3
371,7
360,4
434,5
170,0
343,0
1,2
0,1
8,5
0,0
251,0
71,6
83,1
329,4
251,5
370,6
359,9
435,2
171,0
344,0
1,2
0,1
8,4
0,0
250,9
71,5
83,0
328,5
250,5
369,6
359,2
436,0
172,0
345,0
1,2
0,1
8,4
0,0
250,6
71,6
83,7
328,2
249,5
368,7
358,2
437,6
173,0
346,0
1,1
0,1
8,4
0,0
250,6
71,8
83,6
327,7
248,5
368,0
357,8
438,3
174,0
347,0
1,1
0,1
8,4
0,0
250,6
71,5
83,9
327,5
248,9
367,1
356,8
439,4
175,0
348,0
1,1
0,1
8,4
0,0
250,4
71,4
83,8
326,7
247,8
366,1
356,0
441,0
176,0
349,0
1,1
0,1
8,4
0,0
250,2
71,4
83,4
326,3
247,4
365,0
355,5
442,1
177,0
350,0
1,1
0,1
8,4
0,0
249,8
71,0
83,3
325,7
246,9
364,3
354,4
443,1
178,0
351,0
1,0
0,1
8,3
0,0
249,9
71,4
83,1
325,1
246,2
363,4
353,8
444,2
179,0
352,0
1,0
0,1
8,3
0,0
249,2
71,1
83,0
324,8
245,7
362,7
353,1
445,1
180,0
353,0
1,0
0,1
8,3
0,0
249,2
71,1
82,6
323,7
245,1
361,6
352,1
446,0
181,0
354,0
1,0
0,1
8,3
0,0
248,7
71,5
83,0
323,3
244,3
360,7
351,5
447,3
182,0
355,0
1,0
0,1
8,3
0,0
248,5
71,7
84,4
322,7
245,0
360,1
351,0
447,6
183,0
356,0
1,0
0,1
8,3
0,0
248,0
71,9
83,7
322,0
244,1
359,4
350,1
449,1
184,0
357,0
0,9
0,1
8,4
0,0
247,7
71,5
83,5
321,7
243,7
358,6
349,7
448,9
185,0
358,0
0,9
0,1
8,3
0,0
248,2
71,8
83,4
321,1
242,4
357,6
349,3
450,0
186,0
359,0
0,9
0,1
8,3
0,0
248,3
71,2
83,2
320,5
242,3
356,9
348,6
450,8
187,0
360,0
0,9
0,1
8,2
0,0
247,7
71,2
83,1
320,1
241,1
355,9
347,7
452,1
188,0
361,0
0,9
0,1
8,2
0,0
247,9
71,1
82,9
319,5
240,9
355,0
347,3
453,0
189,0
362,0
0,8
0,1
8,2
0,0
248,7
71,1
82,8
319,1
240,7
354,1
346,5
454,1
190,0
363,0
0,8
0,1
8,2
0,0
248,8
71,2
82,7
318,6
241,1
353,6
346,1
454,7
191,0
364,0
0,7
0,1
8,2
0,0
249,0
71,6
83,8
318,3
239,6
352,8
345,3
455,3
192,0
365,0
0,8
0,1
8,0
0,0
248,5
71,8
83,7
317,4
237,7
352,3
345,1
455,8
193,0
366,0
0,8
0,1
7,9
0,0
248,2
71,4
83,6
317,0
238,1
351,4
344,3
456,1
194,0
367,0
0,8
0,1
7,9
0,0
248,7
71,2
83,6
316,6
237,3
350,7
343,6
456,9
195,0
368,0
0,8
0,1
7,8
0,0
248,9
71,1
83,2
315,9
236,7
349,7
343,2
457,2
196,0
369,0
0,7
0,1
7,8
0,0
249,1
71,2
83,0
315,8
235,3
349,0
342,5
457,6
197,0
370,0
0,7
0,1
7,7
0,0
248,9
71,5
82,9
315,5
235,4
347,9
341,8
458,5
198,0
371,0
0,7
0,1
7,7
0,0
248,8
71,3
83,0
314,7
234,4
347,1
341,2
458,4
199,0
372,0
0,7
0,1
7,6
0,0
248,9
71,0
82,7
314,4
234,0
346,2
340,5
458,7
200,0
373,0
0,7
0,1
7,6
0,0
248,6
71,4
83,2
313,9
234,4
345,5
339,9
458,3
201,0
374,0
0,6
0,1
7,5
0,0
248,9
71,5
83,5
313,2
233,4
344,6
339,3
457,7
202,0
375,0
0,6
0,1
7,4
0,0
248,7
71,2
83,5
312,9
233,3
343,9
338,8
457,6
203,0
376,0
0,6
0,1
7,4
0,0
249,0
71,4
83,4
312,5
232,1
342,7
338,1
456,8
204,0
377,0
0,6
0,1
7,3
0,0
249,2
71,1
83,2
312,1
231,8
342,0
337,5
456,0
205,0
378,0
0,6
0,1
7,3
0,0
249,6
71,4
83,0
311,9
231,1
341,0
336,7
455,7
206,0
379,0
0,6
0,1
7,2
0,0
249,7
70,8
83,0
311,5
231,1
340,0
336,0
454,9
Particulates Calculations
Page 2 of 3
DATA 2018-01-16 EPA PI 20162 RUN 2 CAT 2 MODEL GM 60
207,0
380,0
0,5
0,1
7,5
0,0
248,9
70,7
82,8
310,8
230,4
339,0
335,6
453,7
208,0
381,0
0,5
0,1
7,4
0,0
248,9
71,2
82,6
310,0
229,8
338,0
334,8
453,0
209,0
382,0
0,5
0,1
7,3
0,0
248,9
71,2
83,1
309,5
229,5
337,1
333,9
452,5
210,0
383,0
0,5
0,1
7,3
0,0
248,3
71,1
83,8
308,7
227,8
336,0
333,7
451,2
211,0
384,0
0,5
0,1
7,3
0,0
247,9
70,8
83,4
308,9
229,0
335,3
332,7
450,8
212,0
385,0
0,5
0,1
7,2
0,0
247,9
70,8
83,4
308,1
229,1
334,3
331,9
449,7
213,0
386,0
0,4
0,1
7,3
0,0
248,3
71,0
83,1
307,4
228,8
333,2
331,6
449,0
214,0
387,0
0,4
0,1
7,3
0,0
248,4
70,8
83,1
307,3
228,1
332,2
330,9
447,6
215,0
388,0
0,4
0,1
7,4
0,0
248,0
70,7
82,7
307,4
228,5
331,5
330,1
447,1
216,0
389,0
0,4
0,1
7,4
0,0
247,1
71,0
82,4
307,0
227,9
330,6
329,7
446,1
217,0
390,0
0,4
0,1
7,4
0,0
246,4
70,9
82,5
306,4
228,0
329,8
329,0
446,1
218,0
391,0
0,4
0,1
7,4
0,0
245,3
70,9
83,0
305,9
227,2
328,8
328,2
445,6
219,0
392,0
0,3
0,1
7,4
0,0
244,3
71,2
83,9
305,3
226,3
328,1
327,6
444,8
220,0
393,0
0,3
0,1
7,3
0,0
242,9
71,3
83,3
304,6
225,8
327,2
327,1
444,8
221,0
394,0
0,3
0,1
7,3
0,0
242,2
70,7
83,0
303,9
226,0
326,2
326,2
443,7
222,0
395,0
0,3
0,1
7,3
0,0
241,7
71,3
82,8
303,4
225,4
325,5
325,6
443,7
223,0
396,0
0,3
0,1
7,3
0,0
241,5
70,9
82,5
302,4
224,9
324,5
324,7
443,1
224,0
397,0
0,3
0,1
7,3
0,0
240,9
71,2
82,5
301,4
224,4
323,7
324,3
442,8
225,0
398,0
0,3
0,1
7,3
0,0
240,3
70,7
82,4
300,7
223,5
322,8
323,7
441,7
226,0
399,0
0,2
0,1
7,3
0,0
240,6
70,8
82,2
300,1
222,6
322,1
323,3
441,1
227,0
400,0
0,2
0,1
7,3
0,0
241,0
71,0
82,5
299,6
222,7
321,5
322,5
441,0
228,0
401,0
0,2
0,1
7,3
0,0
240,7
71,2
83,5
299,2
222,4
320,6
322,1
440,2
229,0
402,0
0,2
0,1
7,3
0,0
240,8
71,3
83,2
299,2
221,8
320,0
321,6
440,3
230,0
403,0
0,2
0,1
7,3
0,0
240,6
71,3
82,9
298,4
221,6
319,1
320,7
439,5
231,0
404,0
0,2
0,1
7,3
0,0
240,9
71,3
82,6
298,3
222,0
318,4
320,6
439,7
232,0
405,0
0,2
0,1
7,4
0,0
239,7
71,1
82,5
297,8
221,9
317,5
320,1
440,1
233,0
406,0
0,1
0,1
7,8
0,0
238,4
71,1
82,3
297,4
220,3
317,0
319,6
440,7
234,0
407,0
0,1
0,1
7,6
0,0
237,4
71,0
82,0
297,0
220,0
316,4
319,1
442,4
235,0
408,0
0,1
0,1
7,4
0,0
236,1
70,7
82,1
295,9
220,0
315,4
318,5
443,7
236,0
409,0
0,1
0,1
7,4
0,0
236,0
71,0
82,5
295,4
219,3
314,6
317,9
445,7
237,0
410,0
0,1
0,1
7,3
0,0
235,0
71,1
83,1
294,3
219,7
314,4
317,4
447,0
238,0
411,0
0,1
0,1
7,3
0,0
234,1
71,2
82,7
293,6
218,9
313,8
316,7
449,0
239,0
412,0
0,1
0,1
7,3
0,0
233,5
71,0
82,7
293,1
218,6
313,1
316,1
450,5
240,0
413,0
0,1
0,1
7,2
0,0
233,1
70,9
82,3
292,0
218,2
312,3
315,9
451,7
241,0
414,0
0,1
0,1
7,2
0,0
232,9
70,4
82,1
291,5
217,5
312,2
315,4
453,3
242,0
415,0
0,0
0,1
7,2
0,0
232,6
70,6
82,1
290,7
217,2
311,7
314,9
454,4
Particulates Calculations
Page 3 of 3
DATA 2018-01-16 EPA PI 20162 RUN 2 CAT 2 MODEL GM 60
Manufacturer: HEARTHSTONE
Model:
GM 60
Overall Heating Efficiency:
80,29%
30,08
Run:
2
Combustion Efficiency:
98,96%
364,86
Project #:
PI 20162
Heat Transfer Efficiency:
81,13%
10,47
Test Duration: 242
min
HHV
LHV
Heat Output:
18 702 Btu/h
19 716 kJ/h
Eff
80,29%
86,78%
Heat Input:
23 295 Btu/h
24 557 kJ/h
Comb Eff
98,96%
98,96%
Ultimate CO2
HT Eff
81,13%
87,69%
CO2-ult
19,64
Burn Duration:
4,03
h
Output
19 716
kJ/h
F0
Burn Rate
1,24
kg/h
1,062
Burn Rate:
2,73
lb/h
1,240
kg/h
Grams CO
85
g
Input
24 557
kJ/h
Stack Temp:
287,9
Deg. F
142,2
Deg. C
MC wet
17,09
Air Fuel Ratio (A/F)
Dry Molecular Weight (Md)
Dry Moles Exhaust Gas (Nr):
Air Fuel Ratio (A/F)
Note: In the “Input data”, "Calc. % O2", "Fuel Properties", and
“Mass Balance” columns, [e], [d], [g], [a]. [b], [c], [h], [u], [w],
[j], and [k] refer to their respective variables in Clauses 13.7.3
CSA B415.1 OE Calculations
Page 1 of 1
DATA 2018-01-17 EPA PI 20162 RUN 3 CAT 2 MODEL GM 60 NO FAN
Paramètres
Tous les facteurs de corrections et autres paramètres qui peuvent être modifiés par
l’utilisateur du fichier sont regroupés ici.
Code verrouillage:
HEA
Description du test
Test standard
EPA
Run #
3
Date
17-01-2018
Technicien
M.M
Project #
PI 20162
Description de l'unité
Manufacturier
HEARTHSTONE
Modèle
GM 60
Combustion system
Cat
Appliance type
WOOD STOVE
Firebox volume
2,03
cu ft.
Appliance weight empty
N.A
lbs
Appliance weight full
N.A
lbs
Paramètres du test
Logging time
1
min
Manufacturer's rated heat output
BTU/h Donnée fournie par le manfacturier
Targeted category
2
Targeted output
N.A
BTU/h
Cp steel
N.A
BTU/lb-°F
Échantillonnage
Blank sampling rate
0,20
cuft/min
Internal probe diameter
0,18
in.
Calibration Factor (DGM #1):
0,988
Dimensionless
Equipment number (DGM #1):
EM 178
Calibration Factor (DGM #2):
0,988
Dimensionless
Equipment number (DGM #2):
EM 179
Calibration Factor (DGM #3):
0,986
Equipment number (DGM #3):
EM 070
Dimensionless
Tunnel
Targeted tunnel flow rate
140
scfm
Tunnel diameter
6
in.
Molecular weight
28,78
May be assumed to be 28,78 (EPA) Si B-415 = 29
Pitot tube type
Standard
Pitot tube coefficient
0,99
Dimensionless
Project nu. PI 20162
Date
17-01-2018
Technicien
M.M
Fuel data
Fuel type
Dimension
Fuel specie
D. Fir
HHV
19810,0 kJ/kg
D. Fir
Oak/Maple
%C
48,7
HHV
19 810
19 887
%H
6,9
%C
48,73
50
%O
43,9
%H
6,87
6,6
%Ash
0,5
%O
43,9
42,9
HHV
8519,2 Btu/lb
%Ash
0,5
0,5
LHV
7451,0 Btu/lb
HHV (Btu/lb)
8519
8552
LHV (Btu/lb)
7451
7480
Default Fuel Values
Paramètres
Page 1 of 1
Confidentiel
06/02/2018
Page 1
FUEL LOAD DATA SHEET, CSA B415
Lower
Ideal
Upper
12,8
14,2
15,6
* For boilers, a loading density factor of 10 lb/ft3 is applied
Load Volume:
0,43
cu. ft
Loading Density:
6,5
lbs./ft3
Number of Spaces:
12
Load Density (wet):
30,6
lbs./ft3
Spacer weight:
lbs
Dry Wood Density:
25,4
lbs./ft3
Weight
Ave. MC x
Volume
Ave. MC
Thick Wide xLength
lbs
Weight
Cubic Inches
%
1,5
3,5
17,25
1,94
21,10
21,60
21,10
21,80
21,70
41,54656
90,56
21,5
1,5
3,5
17,25
1,86
19,10
19,60
19,30
19,40
19,40
36,0096
90,56
19,4
3,5
3,5
17,25
4,08
20,60
19,10
19,10
19,90
20,10
80,6208
211,31
19,8
3,5
3,5
17,25
4,09
20,10
20,10
22,00
21,70
22,00
86,6262
211,31
21,2
1,5
0,75
5
0,09
19,10
1,7954
5,63
19,1
1,5
0,75
5
0,09
19,30
1,7756
5,63
19,3
1,5
0,75
5
0,09
19,60
1,764
5,63
19,6
1,5
0,75
5
0,09
19,20
1,8048
5,63
19,2
1,5
0,75
5
0,09
19,30
1,8142
5,63
19,3
1,5
0,75
5
0,10
19,20
1,92
5,63
19,2
1,5
0,75
5
0,09
19,50
1,833
5,63
19,5
1,5
0,75
5
0,10
19,10
1,8336
5,63
19,1
1,5
0,75
5
0,09
19,60
1,8032
5,63
19,6
1,5
0,75
5
0,09
19,40
1,746
5,63
19,4
1,5
0,75
5
0,09
19,80
1,8612
5,63
19,8
1,5
0,75
5
0,10
19,60
1,9208
5,63
19,6
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
SUM MCx 266,67496
19,7 %
Test Load Weight:
13,09
lbs.
Dry Weight:
4,93
kg.
Average Moisture Content: %
Dry:
20,37
Dry(EPA)
20,37
20,37
Wet:
16,92
Dry(B415
20,37
Must be 19-25
must be 15,2-22
Coal Bed Range:
2,6
lbs. to
3,3
lbs.
TEST CHARGE:
Project nu. PI 20162
Coal bed weight:
2,7
lbs.
Date
17-01-2018
Technicien
M.M
Test Load Weight:
Piece Size (in):
Meter Moisture Content
Dry Uncorrected %
Load Data
Page 1 of 1
DATA 2018-01-17 EPA PI 20162 RUN 3 CAT 2 MODEL GM 60 NO FAN
Preload data sheet
Lower
Ideal
Upper
12,79
14,21
15,63
Load Volume:
0,5185
cu. ft
Loading Density:
8,154
lbs./ft3
Number of Spaces:
Load Density (wet):
31,922
lbs./ft3
Spacer weight (lbs):
Dry Wood Density:
26,235797
Weight
Ave. MC x
Volume
Thick Wide x Length
lbs
Weight
Cubic Inches
2
4
8
1,232
21,3
21,6
21,8
22
22,1
26,80832
64,00
2
4
8
1,268
22,3
22,4
21,9
21,8
21,9
27,97208
64,00
2
4
8
1,188
23
22,8
21,9
22,4
22,6
26,77752
64,00
2
4
8
1,32
23
22,3
21,9
21,6
21,4
29,0928
64,00
2
4
8
1,28
22,3
22,8
22,4
22,9
21,9
28,7488
64,00
2
4
8
1,25
23
23,4
23,3
22,9
23
28,9
64,00
2
4
8
1,044
23,6
23,4
23,6
23,5
23,2
24,49224
64,00
2
4
8
1,058
19,6
19,3
20,1
20,6
20,9
21,2658
64,00
2
4
8
1,142
20,6
20,8
20,9
20,7
20,8
23,70792
64,00
2
4
8
1,25
21,3
21,6
21,9
21,4
21,8
27
64,00
2
4
8
1,134
22
22,3
21,6
20,9
21,1
24,47172
64,00
2
4
8
1,144
20,8
20,9
20,4
20,8
20,7
23,70368
64,00
2
4
8
1,12
21,6
21,4
21,3
20,9
20,8
23,744
64,00
2
4
8
1,122
19,6
19,9
19,3
19,8
19,6
22,03608
64,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
SUM MCx 358,72096
PreTest Load Weight:
16,55
lbs.
Dry Weight:
6,17
kg.
Average Moisture Content: %
Dry:
21,67
21,67
Wet:
17,81
Must be 18-28
must be 15,2-22
Project nu. PI 20162
Date
17-01-2018
Technicien
M.M
Test Load Weight:
Piece Size (in):
Meter Moisture Content
Dry Uncorrected %
Preload Data
Page 1 of 1
DATA 2018-01-17 EPA PI 20162 RUN 3 CAT 2 MODEL GM 60 NO FAN
Filter set weight
Ambient
blank (g)
Date
Heure
probe
front
back
gasket
probe
front
back
gasket
probe
front
back
gasket
Filter
Number
9
21
22
8
11
23
24
9
42
25
26
10
27
Before (1)
Before (2)
Before (3)
Before (4)
Before (5)
61,4481
0,1263
0,1262
35,7852
93,7241
0,1245
0,1241
35,7870
110,3110
0,1246
0,1266
35,3365
0,1285
16/01/2018
17:00
Before (6)
61,4481
0,1263
0,1261
35,7851
93,7242
0,1246
0,1241
35,7869
110,3111
0,1245
0,1265
35,3366
0,1286
17/01/2018
10:00
After (1)
61,4487
0,1264
0,1262
35,7866
93,7257
0,1243
0,1236
35,7888
110,3113
0,1246
0,1260
35,3386
0,1288
17/01/2018
16:00
After (2)
61,4481
0,1261
0,1261
35,7863
93,7243
0,1240
0,1234
35,7883
110,3111
0,1244
0,1258
35,3383
0,1286
29/01/2018
08:00
After (3)
61,4481
0,1261
0,1261
35,7863
93,7243
0,1240
0,1234
35,7883
110,3112
0,1244
0,1259
35,3383
0,1286
05/02/2018
08:00
After (4)
After (5)
After (6)
61,4481
0,1261
0,1261
35,7863
93,7243
0,1240
0,1234
35,7883
110,3112
0,1244
0,1259
35,3383
0,1286
05/02/2018
08:00
Difference
0,0000
-0,0002
0,0000
0,0012
0,0001
-0,0006
-0,0007
0,0014
0,0001
-0,0001
-0,0006
0,0017
0,0000
Total (mg)
1
1,2
1,1
0
Total ajusté (mg)
1,00
1,20
1,10
Project nu. PI 20162
Date
17-01-2018
Technicien
mm
System 2 (g)
System 1 (g) 1st hour
System 1 (g)
Filter set weight
Page 1 of 1
DATA 2018-01-17 EPA PI 20162 RUN 3 CAT 2 MODEL GM 60 NO FAN
SFBA EPA EMISSION RESULTS
RESULTS
Average emission rate:
0,3
g/hr
Burn Rate :
1,170
Dry kg/hr
Test Duration:
253
min
PRESSURE FACTOR:
DGM 1
0,98366
BAROMETRIC PRESSURE
DGM 2
0,98299
Average:
30,194414 in Hg
DGM 3
1,00917
Start:
30,268239 in Hg
End:
30,120589 in Hg
TEMPERATURE FACTORS
DGM 1
0,98553
DGM 2
0,98425
DGM CONTROLLER VALUES
DGM 3
0,99208
DGM 1
Final: 21940,714
Cuft
Initial: 21894,505
Cuft
VOLUMES SAMPLED
DGM 1
44,253
SCft
DGM 2
Final: 19330,921
Cuft
DGM 2
44,804
Scft
Initial: 19284,070
Cuft
DGM 3
30,585
SCft
DGM #3
Final:
717,870
Cuft
Initial:
686,900
Cuft
TOTAL TUNNEL VOLUME :
43388
TEMPERATURES
SAMPLE RATIOS
DGM 1
535,752
°R
Sample Train 1:
980,451
DGM 2
536,447
°R
Sample Train 2:
968,395
CALIBRATION FACTORS
Paticulate concentration
DGM 1
0,9879
Sample Train 1
0,000027
g/dscf
DGM 2
0,9884
Sample Train 2
0,000025
g/dscf
DGM #3
0,9864
Room
0,000000
g/dscf
TUNNEL FLOW RATE:
171,492
Dscfm
TOTAL EMISSIONS
PARTICULATE CATCH
Sample Train 1
1,18
g
Total Sample Train 1:
1,20 mg
Sample Train 2
1,07
g
Total Sample Train 2:
1,10 mg
Total Sample Train 1 1st hour:
1,00 mg
EMISSION RATES
Sample Train 1
0,28
g/hr
Sample Train 2
0,25
g/hr
1st hour emission rate
0,98
g/hr
DEVIATION:
4,97%
Train 1
Train 2
Cs
2,712E-05
2,45516E-05
Particulates Calculations
Page 1 of 1
DATA 2018-01-17 EPA PI 20162 RUN 3 CAT 2 MODEL GM 60 NO FAN
Average
0,11
10,09
#DIV/0!
301,15
72,22
90,62
440,82
437,51
383,10
371,34
399,13
*****
*1
*2
*3
*4
*5
*6
*7
*8
Elapsed
Weight
Flue
Room
Tunnel
Unit
Unit
Unit
Unit
Unit
Time
Raw data row
Remaining
CO
CO2
O2
Gas
Temp
Dry Bulb
Top
Back
R.Side
L.Side
Bottom
min
lbs
%%%
°F
°F
°F
°F
°F
°F
°F
°F
0,00
203,00
13,1
0,0
4,5
0,0
279,2
71,5
121,2
364,4
440,9
369,6
335,2
581,2
1,0
204,0
13,0
0,2
1,1
0,0
297,6
71,7
99,3
358,4
440,6
368,7
334,5
574,3
2,0
205,0
12,8
0,1
4,5
0,0
326,2
71,5
99,9
357,4
439,7
367,9
333,4
569,3
3,0
206,0
12,7
0,1
6,0
0,0
347,7
71,8
101,6
359,7
438,6
366,5
332,4
562,1
4,0
207,0
12,6
0,1
8,3
0,0
340,5
71,6
95,7
366,6
437,1
365,2
331,5
559,7
5,0
208,0
12,5
0,1
9,0
0,0
321,0
71,7
92,0
368,5
435,3
363,7
330,4
554,6
6,0
209,0
12,5
0,0
5,0
0,0
307,5
71,6
91,1
368,8
433,4
361,9
329,2
550,7
7,0
210,0
12,4
0,0
4,7
0,0
299,2
71,2
90,5
367,6
431,0
360,1
328,0
546,8
8,0
211,0
12,4
0,0
4,8
0,0
294,4
71,2
89,8
366,3
428,5
358,3
326,8
543,0
9,0
212,0
12,3
0,0
5,1
0,0
291,7
71,5
90,0
366,2
425,9
356,1
325,3
538,2
10,0
213,0
12,2
0,1
7,8
0,0
292,8
71,7
90,4
368,6
423,0
353,8
323,9
533,7
11,0
214,0
12,1
0,1
10,6
0,0
302,0
71,6
91,9
371,8
420,3
351,8
322,5
528,9
12,0
215,0
12,0
0,2
11,6
0,0
307,7
72,1
92,1
377,1
417,6
349,4
321,3
523,6
13,0
216,0
11,9
0,1
11,0
0,0
306,8
71,6
91,8
383,1
415,0
347,4
320,2
519,4
14,0
217,0
11,8
0,1
10,7
0,0
303,3
71,4
91,5
386,8
412,3
345,8
319,3
516,1
15,0
218,0
11,7
0,1
9,3
0,0
302,7
71,4
91,6
390,0
409,7
344,4
318,7
511,2
16,0
219,0
11,6
0,1
8,8
0,0
304,1
71,3
91,5
393,7
407,3
342,8
318,2
506,8
17,0
220,0
11,5
0,1
11,3
0,0
309,5
71,3
92,3
398,8
405,0
341,6
317,6
502,0
18,0
221,0
11,3
0,3
12,1
0,0
315,6
71,7
92,8
405,1
402,9
340,7
317,4
497,2
19,0
222,0
11,3
0,3
12,5
0,0
321,4
71,7
93,1
412,2
400,9
339,7
317,3
493,0
20,0
223,0
11,1
0,2
13,0
0,0
325,7
71,9
93,0
418,3
399,2
338,8
317,2
489,0
21,0
224,0
11,0
0,1
12,7
0,0
328,7
72,1
93,2
424,8
397,6
338,4
317,6
485,0
22,0
225,0
10,9
0,1
13,3
0,0
332,3
72,1
94,0
431,5
396,2
338,3
317,6
481,4
23,0
226,0
10,7
0,2
13,5
0,0
334,6
71,9
93,8
436,5
395,1
338,2
317,9
476,8
24,0
227,0
10,6
0,2
13,3
0,0
336,6
72,0
94,0
441,7
394,2
338,4
318,5
474,0
25,0
228,0
10,5
0,1
13,5
0,0
339,3
72,2
94,3
447,4
393,4
338,9
318,9
469,2
26,0
229,0
10,4
0,1
13,9
0,0
342,9
72,2
93,6
454,0
393,0
339,5
319,6
465,5
27,0
230,0
10,2
0,1
14,0
0,0
346,9
72,2
94,0
459,2
392,7
340,2
320,5
461,9
28,0
231,0
10,1
0,1
14,4
0,0
351,4
72,0
94,3
465,3
392,5
340,9
321,3
458,5
29,0
232,0
10,0
0,1
15,0
0,0
354,9
71,8
94,5
471,7
392,6
341,9
322,3
454,3
30,0
233,0
9,8
0,2
15,2
0,0
357,2
72,3
94,8
477,4
392,9
342,9
323,4
450,7
31,0
234,0
9,7
0,4
15,2
0,0
359,3
72,1
95,4
483,4
393,4
344,0
324,8
447,3
32,0
235,0
9,6
0,5
15,1
0,0
360,8
72,4
95,9
488,7
394,1
345,4
326,1
444,2
33,0
236,0
9,4
0,6
15,4
0,0
362,9
72,2
96,0
495,8
395,0
347,1
327,5
441,5
34,0
237,0
9,3
0,6
15,5
0,0
365,1
72,3
96,1
502,2
396,0
348,5
329,3
439,0
35,0
238,0
9,2
0,7
15,6
0,0
366,8
72,1
96,4
508,1
397,1
350,3
331,1
436,2
36,0
239,0
9,1
0,7
15,6
0,0
369,3
72,5
96,7
513,6
398,4
352,1
333,0
433,0
37,0
240,0
8,9
0,7
15,8
0,0
370,6
72,4
96,4
519,5
399,6
354,2
335,0
430,2
38,0
241,0
8,8
0,7
15,8
0,0
372,0
72,0
96,9
523,7
401,2
356,3
337,0
427,7
39,0
242,0
8,6
0,8
15,8
0,0
373,4
72,4
97,2
528,6
402,7
358,6
338,9
424,8
40,0
243,0
8,5
0,9
15,8
0,0
374,3
72,7
97,0
533,8
404,5
360,8
341,0
421,1
41,0
244,0
8,3
0,9
15,9
0,0
375,8
72,7
97,6
538,5
406,3
363,5
343,1
418,8
42,0
245,0
8,2
1,3
15,8
0,0
376,8
72,1
97,7
542,2
408,2
365,8
345,0
415,7
43,0
246,0
8,1
1,4
15,8
0,0
376,8
72,5
97,8
545,8
410,1
368,3
347,2
414,7
44,0
247,0
7,9
1,2
15,8
0,0
377,4
72,1
98,1
548,7
412,2
370,7
349,7
412,1
45,0
248,0
7,8
0,9
15,9
0,0
377,2
72,3
98,2
551,2
414,3
373,4
351,9
409,5
46,0
249,0
7,7
0,6
15,8
0,0
377,8
72,7
97,8
554,3
416,4
375,9
354,3
407,6
47,0
250,0
7,6
0,4
15,5
0,0
377,1
72,8
97,6
556,8
418,6
378,6
356,7
405,2
48,0
251,0
7,4
0,3
15,4
0,0
376,9
72,4
97,5
556,5
420,6
381,0
359,3
403,0
49,0
252,0
7,3
0,3
15,4
0,0
376,4
72,8
97,7
557,6
422,9
383,7
361,6
400,8
50,0
253,0
7,2
0,2
15,3
0,0
375,1
73,2
97,3
559,3
425,1
386,1
363,9
398,1
51,0
254,0
7,1
0,2
15,2
0,0
374,4
73,0
97,9
561,0
427,4
388,5
366,3
396,0
52,0
255,0
7,0
0,2
15,2
0,0
373,1
72,7
97,4
561,2
429,6
390,9
368,4
393,4
53,0
256,0
6,9
0,2
15,2
0,0
373,0
72,9
97,2
561,0
431,7
393,2
370,5
392,9
54,0
257,0
6,8
0,1
15,2
0,0
372,6
72,4
98,3
563,7
433,8
395,4
372,9
390,9
55,0
258,0
6,7
0,2
15,2
0,0
372,1
72,6
97,6
562,5
435,8
397,6
374,8
388,7
56,0
259,0
6,5
0,2
15,3
0,0
372,4
72,9
97,5
561,9
437,7
399,5
377,0
387,3
57,0
260,0
6,4
0,1
15,3
0,0
371,5
72,6
97,7
563,7
439,9
401,6
378,8
385,6
58,0
261,0
6,3
0,1
15,3
0,0
371,4
72,1
96,6
563,4
441,8
403,8
380,6
384,0
59,0
262,0
6,2
0,1
15,2
0,0
370,6
72,8
96,9
564,5
443,7
406,1
383,0
382,1
60,0
263,0
6,1
0,2
15,3
0,0
370,6
73,0
97,0
565,5
445,6
408,2
384,4
379,8
61,0
264,0
6,0
0,2
15,3
0,0
370,8
73,3
97,8
566,8
447,4
410,4
386,1
378,1
62,0
265,0
5,9
0,3
15,4
0,0
370,7
72,2
97,8
567,1
449,3
412,0
387,8
376,7
63,0
266,0
5,8
0,3
15,4
0,0
370,6
72,8
97,8
566,4
450,9
414,2
389,3
376,3
64,0
267,0
5,7
0,3
15,5
0,0
370,6
72,6
98,2
567,9
452,6
416,1
390,9
374,9
65,0
268,0
5,5
0,4
15,5
0,0
371,3
72,8
97,9
567,2
454,5
418,1
392,6
373,5
66,0
269,0
5,4
0,4
15,5
0,0
371,3
72,9
97,2
568,3
456,1
419,9
394,1
372,4
67,0
270,0
5,4
0,3
15,6
0,0
371,2
73,1
97,1
567,9
457,8
421,6
395,5
371,1
68,0
271,0
5,2
0,3
15,7
0,0
371,1
72,8
96,9
568,8
459,6
423,2
397,1
369,9
69,0
272,0
5,1
0,2
15,7
0,0
371,0
72,8
96,9
569,8
461,4
425,1
398,7
368,8
70,0
273,0
5,0
0,1
15,8
0,0
370,1
73,5
96,7
570,9
463,3
426,8
400,1
366,7
71,0
274,0
4,9
0,1
15,7
0,0
368,5
73,2
97,1
572,1
465,0
429,0
401,7
365,6
72,0
275,0
4,8
0,1
15,8
0,0
367,0
73,0
97,0
573,7
466,8
430,8
402,9
364,7
73,0
276,0
4,7
0,1
15,8
0,0
366,2
73,0
96,6
572,3
468,6
432,8
404,5
363,9
74,0
277,0
4,6
0,1
15,7
0,0
364,6
73,0
97,3
573,3
470,5
434,7
405,9
363,4
75,0
278,0
4,6
0,1
15,6
0,0
363,3
73,5
97,1
571,9
472,2
436,5
407,4
362,7
76,0
279,0
4,4
0,2
15,6
0,0
361,3
73,3
96,6
571,1
474,0
438,6
408,8
361,9
77,0
280,0
4,3
0,2
15,4
0,0
359,4
73,3
96,2
569,4
475,8
440,1
410,5
361,1
78,0
281,0
4,3
0,1
15,3
0,0
358,0
72,9
96,3
569,3
477,5
442,0
411,7
360,2
79,0
282,0
4,2
0,1
15,0
0,0
355,3
73,1
95,7
568,4
479,3
443,4
413,3
359,1
80,0
283,0
4,1
0,0
14,5
0,0
353,0
73,3
95,5
568,1
481,1
445,3
414,7
358,0
81,0
284,0
4,0
0,0
14,1
0,0
349,5
73,1
94,8
567,8
482,9
446,9
416,2
356,8
82,0
285,0
4,0
0,0
13,7
0,0
346,7
73,5
95,6
566,2
484,4
448,5
417,4
356,9
83,0
286,0
3,9
0,0
13,4
0,0
343,3
73,6
94,9
565,2
486,1
449,8
418,6
355,3
84,0
287,0
3,8
0,0
13,2
0,0
340,6
73,2
94,9
560,5
487,4
450,9
419,8
356,0
85,0
288,0
3,7
0,0
13,1
0,0
338,1
73,3
95,3
557,7
488,9
451,8
420,9
355,3
86,0
289,0
3,6
0,0
13,0
0,0
335,5
73,6
94,3
554,7
490,4
452,3
422,2
354,8
87,0
290,0
3,6
0,0
12,9
0,0
333,5
73,4
93,7
550,7
491,6
452,8
423,4
354,7
88,0
291,0
3,5
0,0
12,8
0,0
331,5
73,3
93,7
546,9
492,7
453,5
424,4
353,9
89,0
292,0
3,4
0,0
12,8
0,0
329,6
73,4
93,1
545,0
493,8
453,7
425,3
353,5
90,0
293,0
3,4
0,0
12,9
0,0
327,3
72,6
93,1
541,4
494,7
453,8
426,5
353,3
91,0
294,0
3,3
0,0
12,9
0,0
325,3
73,2
93,2
541,0
495,7
453,5
427,4
352,2
92,0
295,0
3,3
0,0
12,8
0,0
323,0
73,1
93,3
536,4
496,4
454,1
428,1
351,7
93,0
296,0
3,2
0,0
12,7
0,0
321,0
73,5
92,8
535,5
497,2
454,0
428,5
351,6
94,0
297,0
3,2
0,0
12,4
0,0
319,3
73,4
92,9
533,3
497,7
454,1
429,3
352,0
95,0
298,0
3,1
0,0
12,3
0,0
317,9
73,0
92,8
528,5
498,2
454,2
429,9
351,6
96,0
299,0
3,0
0,0
13,1
0,0
317,2
72,8
92,5
525,2
498,9
454,3
430,6
351,8
97,0
300,0
3,0
0,0
13,2
0,0
315,4
72,4
91,9
522,6
499,4
453,7
430,8
351,0
98,0
301,0
2,9
0,0
13,1
0,0
313,5
72,6
91,7
520,9
499,9
453,7
431,4
350,9
99,0
302,0
2,9
0,0
13,0
0,0
312,4
73,4
91,6
517,5
500,0
454,0
431,7
351,5
100,0
303,0
2,8
0,0
12,5
0,0
310,7
72,7
91,3
515,0
500,5
454,1
432,1
351,1
Particulates Calculations
Page 1 of 3
DATA 2018-01-17 EPA PI 20162 RUN 3 CAT 2 MODEL GM 60 NO FAN
101,0
304,0
2,8
0,0
12,5
0,0
308,5
72,8
91,4
512,5
500,9
454,0
432,4
351,6
102,0
305,0
2,7
0,0
12,4
0,0
307,0
72,9
91,6
510,4
501,2
453,7
432,7
351,5
103,0
306,0
2,7
0,0
12,2
0,0
305,3
72,0
91,6
508,1
501,6
453,7
432,9
352,0
104,0
307,0
2,7
0,0
11,9
0,0
303,5
72,3
91,6
505,8
501,7
453,6
433,2
352,4
105,0
308,0
2,6
0,0
11,3
0,0
302,4
71,8
91,4
502,5
501,8
454,1
433,5
353,7
106,0
309,0
2,6
0,0
10,8
0,0
301,5
72,2
91,1
500,0
501,7
454,1
434,1
354,5
107,0
310,0
2,5
0,0
10,8
0,0
300,5
72,1
90,9
496,6
501,5
454,0
434,3
355,4
108,0
311,0
2,5
0,0
10,6
0,0
299,9
72,2
90,5
494,3
501,1
453,6
434,7
356,0
109,0
312,0
2,5
0,0
10,6
0,0
298,8
72,3
90,4
490,5
500,7
453,3
434,7
356,3
110,0
313,0
2,5
0,0
10,4
0,0
297,1
71,8
90,4
488,3
500,3
452,5
434,8
356,9
111,0
314,0
2,5
0,0
10,3
0,0
296,1
71,6
89,9
484,8
499,4
451,6
434,6
357,1
112,0
315,0
2,4
0,0
10,3
0,0
295,0
71,6
89,6
481,2
498,3
451,1
434,8
357,9
113,0
316,0
2,4
0,0
10,3
0,0
294,1
72,2
90,3
478,4
497,5
450,3
434,4
359,2
114,0
317,0
2,3
0,0
10,2
0,0
292,9
71,8
89,9
476,7
496,5
449,6
433,8
359,7
115,0
318,0
2,3
0,0
10,2
0,0
292,3
72,3
89,9
472,1
495,3
448,6
433,5
361,0
116,0
319,0
2,3
0,0
10,1
0,0
291,4
71,8
90,1
470,0
493,9
448,1
433,1
361,9
117,0
320,0
2,3
0,0
10,1
0,0
290,8
71,9
90,0
467,7
492,8
447,2
432,7
362,7
118,0
321,0
2,3
0,0
10,1
0,0
290,1
72,0
90,1
465,3
491,5
446,4
432,3
362,9
119,0
322,0
2,2
0,0
10,0
0,0
289,5
72,4
89,5
463,9
490,2
445,7
431,7
364,3
120,0
323,0
2,2
0,0
10,0
0,0
288,6
72,1
89,2
460,2
488,9
445,0
431,3
364,8
121,0
324,0
2,2
0,0
9,8
0,0
288,5
72,4
89,0
458,4
487,8
443,8
430,0
365,5
122,0
325,0
2,2
0,0
9,7
0,0
288,1
72,7
88,8
456,4
486,4
442,5
429,4
366,0
123,0
326,0
2,2
0,0
9,7
0,0
287,4
73,0
90,0
454,7
485,2
441,7
428,7
367,5
124,0
327,0
2,1
0,0
9,7
0,0
286,8
72,5
89,3
451,9
484,0
440,5
427,9
368,0
125,0
328,0
2,1
0,0
9,6
0,0
286,6
72,6
89,2
450,3
482,8
439,6
427,2
368,3
126,0
329,0
2,1
0,0
9,6
0,0
286,1
72,6
89,7
448,4
481,5
438,6
426,4
369,2
127,0
330,0
2,0
0,0
9,5
0,0
285,8
72,4
89,2
447,1
480,4
437,7
425,5
370,2
128,0
331,0
2,0
0,0
9,4
0,0
285,5
72,5
88,7
445,4
479,1
436,5
424,5
370,4
129,0
332,0
2,0
0,0
9,3
0,0
284,9
72,6
89,1
443,9
477,9
435,5
424,0
371,0
130,0
333,0
2,0
0,0
8,3
0,0
285,0
72,5
88,3
441,7
476,8
434,1
422,9
372,4
131,0
334,0
2,0
0,0
7,9
0,0
284,5
72,8
88,9
439,6
475,4
433,2
422,0
373,3
132,0
335,0
2,0
0,0
7,8
0,0
284,1
72,8
88,8
437,3
474,3
431,9
420,9
372,9
133,0
336,0
1,9
0,0
7,8
0,0
283,7
73,0
89,3
435,7
473,0
430,7
419,6
373,6
134,0
337,0
1,9
0,0
7,8
0,0
283,3
72,6
88,7
433,9
471,8
428,9
418,3
374,2
135,0
338,0
1,9
0,0
7,8
0,0
283,0
72,5
89,3
432,1
470,5
427,8
417,1
375,4
136,0
339,0
1,9
0,0
7,8
0,0
282,3
72,6
89,1
430,8
469,4
426,4
415,8
375,8
137,0
340,0
1,9
0,0
7,8
0,0
282,5
72,7
89,0
428,4
468,2
424,5
414,7
376,2
138,0
341,0
1,9
0,0
7,7
0,0
282,5
72,5
88,6
427,4
466,9
422,7
413,2
376,7
139,0
342,0
1,8
0,0
7,7
0,0
282,4
72,5
88,7
425,6
465,8
421,7
411,7
377,2
140,0
343,0
1,8
0,0
7,7
0,0
282,5
72,1
88,5
423,4
464,6
419,7
410,4
377,7
141,0
344,0
1,8
0,0
7,7
0,0
282,4
72,4
88,2
422,8
463,5
417,9
409,0
377,9
142,0
345,0
1,8
0,0
7,7
0,0
282,4
72,5
88,3
420,3
462,3
416,1
407,5
378,6
143,0
346,0
1,8
0,0
7,7
0,0
281,4
72,6
88,2
418,5
461,3
414,1
405,9
377,6
144,0
347,0
1,8
0,0
7,7
0,0
280,7
73,0
88,8
418,0
460,3
412,5
404,2
378,2
145,0
348,0
1,8
0,0
7,7
0,0
280,8
72,6
88,4
416,5
459,2
410,8
402,8
378,3
146,0
349,0
1,7
0,0
7,7
0,0
280,7
72,4
88,3
414,4
458,3
409,1
401,2
379,5
147,0
350,0
1,7
0,0
7,6
0,0
280,5
72,3
88,0
413,5
457,4
407,5
400,0
379,6
148,0
351,0
1,7
0,0
7,6
0,0
280,2
72,1
87,7
412,2
456,6
405,7
398,5
379,8
149,0
352,0
1,7
0,0
7,6
0,0
279,7
72,1
87,7
411,3
455,7
403,9
397,1
380,1
150,0
353,0
1,7
0,0
7,6
0,0
279,3
72,0
88,1
410,0
454,7
402,4
395,7
380,1
151,0
354,0
1,6
0,0
7,6
0,0
279,1
72,2
87,6
408,5
454,0
400,7
394,5
380,5
152,0
355,0
1,6
0,0
7,5
0,0
279,1
71,9
87,7
407,7
453,1
398,9
393,0
380,3
153,0
356,0
1,6
0,0
7,5
0,0
278,6
72,7
87,6
406,3
452,2
396,9
391,4
380,4
154,0
357,0
1,6
0,0
7,5
0,0
278,5
72,4
87,5
405,6
451,4
395,7
390,3
380,9
155,0
358,0
1,6
0,0
7,6
0,0
277,5
72,4
88,1
404,4
450,7
393,9
389,0
380,8
156,0
359,0
1,6
0,0
7,6
0,0
277,6
71,9
87,9
402,4
449,7
392,3
387,2
380,7
157,0
360,0
1,6
0,0
7,6
0,0
277,6
71,9
87,5
402,1
448,8
390,6
385,8
380,2
158,0
361,0
1,5
0,0
7,6
0,0
277,1
71,8
87,1
400,3
448,1
389,1
384,5
381,0
159,0
362,0
1,5
0,0
7,6
0,0
277,1
72,1
87,3
399,9
447,2
387,8
383,1
381,5
160,0
363,0
1,5
0,0
7,6
0,0
276,6
72,1
86,8
399,5
446,5
386,2
382,1
381,5
161,0
364,0
1,5
0,0
7,5
0,0
275,8
72,1
87,0
398,4
445,6
384,7
380,9
381,5
162,0
365,0
1,5
0,0
7,5
0,0
276,1
71,7
87,9
397,5
444,9
383,3
379,5
381,2
163,0
366,0
1,5
0,0
7,5
0,0
275,7
72,2
87,4
396,5
444,1
381,9
378,3
382,0
164,0
367,0
1,5
0,0
7,4
0,0
275,4
72,1
87,6
395,7
442,9
380,4
377,3
381,5
165,0
368,0
1,4
0,0
7,4
0,0
274,8
72,4
87,8
394,0
442,2
379,1
376,2
382,2
166,0
369,0
1,4
0,0
7,4
0,0
274,4
72,2
87,2
394,3
441,4
377,8
375,1
382,0
167,0
370,0
1,4
0,0
7,3
0,0
274,2
72,2
87,5
393,7
440,5
376,7
374,2
382,4
168,0
371,0
1,4
0,0
7,3
0,0
274,5
72,0
88,3
392,5
439,7
375,3
373,0
382,0
169,0
372,0
1,4
0,0
7,3
0,0
274,7
71,9
87,8
392,5
438,9
374,1
372,0
382,2
170,0
373,0
1,3
0,0
7,3
0,0
275,2
71,8
87,4
391,7
438,1
373,0
371,2
382,2
171,0
374,0
1,3
0,0
7,2
0,0
275,0
71,7
86,9
390,7
437,3
371,7
370,3
382,4
172,0
375,0
1,3
0,0
7,2
0,0
275,2
71,9
87,3
389,8
436,6
370,5
369,1
382,1
173,0
376,0
1,3
0,0
7,2
0,0
275,0
71,8
87,3
388,9
435,6
369,2
368,2
382,3
174,0
377,0
1,3
0,0
7,2
0,0
274,4
72,4
87,5
388,2
434,6
367,9
367,1
381,1
175,0
378,0
1,3
0,0
7,2
0,0
274,2
72,6
87,2
387,5
433,8
366,7
366,0
380,7
176,0
379,0
1,2
0,0
7,1
0,0
273,3
72,3
87,4
386,9
433,0
365,4
365,2
380,2
177,0
380,0
1,2
0,0
7,1
0,0
273,4
72,1
87,6
386,4
432,2
364,5
364,2
380,9
178,0
381,0
1,2
0,0
7,1
0,0
272,8
72,2
87,2
385,7
431,3
363,1
363,3
381,0
179,0
382,0
1,2
0,0
7,1
0,0
272,2
72,0
86,7
384,9
430,3
361,8
362,2
379,5
180,0
383,0
1,2
0,0
7,0
0,0
272,2
71,8
87,1
384,4
429,5
360,8
361,3
379,8
181,0
384,0
1,2
0,0
7,0
0,0
272,0
71,9
87,3
383,1
428,7
359,7
360,4
379,1
182,0
385,0
1,1
0,0
6,9
0,0
271,4
71,8
86,6
382,7
427,9
358,5
359,5
379,0
183,0
386,0
1,1
0,0
6,8
0,0
271,6
71,7
86,1
381,9
426,9
357,7
358,5
378,1
184,0
387,0
1,1
0,0
6,8
0,0
270,9
72,1
86,7
380,2
426,2
356,2
357,4
378,0
185,0
388,0
1,1
0,0
6,8
0,0
270,4
72,1
87,0
379,3
425,0
355,3
356,8
377,3
186,0
389,0
1,1
0,0
6,8
0,0
269,6
72,2
86,8
378,3
424,1
354,2
355,7
376,7
187,0
390,0
1,1
0,0
6,8
0,0
268,9
71,9
87,5
378,2
423,3
353,0
354,7
376,1
188,0
391,0
1,1
0,0
6,9
0,0
268,9
71,7
87,1
377,9
422,4
352,0
353,9
376,0
189,0
392,0
1,0
0,0
7,2
0,0
268,5
71,6
87,3
377,1
421,3
350,9
353,4
375,5
190,0
393,0
1,0
0,0
7,2
0,0
268,7
71,5
87,0
376,9
420,5
350,0
352,4
374,7
191,0
394,0
1,0
0,0
7,2
0,0
268,3
71,8
87,0
376,2
419,7
349,0
351,7
374,4
192,0
395,0
1,0
0,0
7,2
0,0
268,6
71,7
86,9
375,7
418,8
348,1
350,7
373,8
193,0
396,0
1,0
0,0
7,1
0,0
268,9
71,8
86,9
375,1
417,9
347,0
350,1
373,4
194,0
397,0
1,0
0,0
7,1
0,0
269,5
72,1
86,8
374,3
417,0
345,9
349,4
373,4
195,0
398,0
1,0
0,0
7,0
0,0
269,3
72,2
86,9
374,1
416,1
344,9
348,5
372,2
196,0
399,0
0,9
0,0
7,0
0,0
269,0
72,4
87,1
373,7
415,3
344,2
347,6
371,8
197,0
400,0
0,9
0,0
7,0
0,0
269,2
72,2
87,1
373,6
414,5
343,0
346,9
371,4
198,0
401,0
0,9
0,0
7,0
0,0
269,5
72,0
86,5
372,3
413,7
342,2
346,1
370,8
199,0
402,0
0,9
0,0
7,0
0,0
269,5
71,9
86,5
372,5
412,9
341,3
345,4
370,0
200,0
403,0
0,9
0,0
7,0
0,0
270,2
71,7
87,2
372,4
412,1
340,4
344,6
369,8
201,0
404,0
0,8
0,0
8,0
0,0
267,8
71,9
86,9
372,3
411,1
339,7
344,0
370,0
202,0
405,0
0,9
0,0
8,1
0,0
265,2
71,8
86,2
371,3
410,4
338,7
343,3
370,3
203,0
406,0
0,8
0,0
7,9
0,0
262,5
71,3
86,2
370,5
409,6
338,0
342,9
371,9
204,0
407,0
0,8
0,0
7,9
0,0
260,6
71,3
86,2
369,1
408,7
337,3
342,3
373,7
205,0
408,0
0,8
0,0
7,9
0,0
259,1
72,1
86,3
367,9
407,8
336,2
341,5
375,4
206,0
409,0
0,8
0,0
7,9
0,0
257,0
72,2
86,3
367,3
407,1
335,6
341,0
377,5
Particulates Calculations
Page 2 of 3
DATA 2018-01-17 EPA PI 20162 RUN 3 CAT 2 MODEL GM 60 NO FAN
207,0
410,0
0,8
0,0
7,9
0,0
255,7
72,2
86,4
366,7
406,2
334,9
340,4
379,8
208,0
411,0
0,7
0,0
7,9
0,0
254,8
71,8
85,9
365,7
405,6
334,5
339,8
382,5
209,0
412,0
0,7
0,0
7,9
0,0
253,6
71,9
86,2
364,7
404,7
334,0
339,4
385,1
210,0
413,0
0,7
0,0
7,9
0,0
253,0
71,8
86,4
364,3
404,1
333,5
338,8
387,6
211,0
414,0
0,7
0,0
7,9
0,0
253,1
71,6
86,1
363,6
403,6
333,3
338,6
389,7
212,0
415,0
0,6
0,0
7,9
0,0
252,6
71,7
86,3
362,9
402,7
333,0
338,2
392,3
213,0
416,0
0,6
0,0
7,9
0,0
251,9
71,4
86,0
362,8
402,1
332,7
337,8
394,4
214,0
417,0
0,6
0,0
7,8
0,0
251,4
71,3
85,7
361,4
401,4
332,5
337,7
396,6
215,0
418,0
0,6
0,0
7,8
0,0
251,5
72,1
85,7
360,4
400,9
332,0
337,0
398,6
216,0
419,0
0,6
0,0
7,8
0,0
250,7
72,2
86,0
359,8
400,2
331,8
336,8
399,6
217,0
420,0
0,6
0,0
7,8
0,0
250,4
72,1
86,3
359,2
399,6
331,5
336,4
401,6
218,0
421,0
0,6
0,0
7,8
0,0
250,6
72,2
85,6
358,7
399,1
331,2
336,1
403,1
219,0
422,0
0,5
0,0
7,8
0,0
251,0
71,7
85,5
357,5
398,5
331,0
335,8
404,6
220,0
423,0
0,5
0,0
7,7
0,0
251,2
71,9
85,8
357,7
397,9
330,7
335,7
405,5
221,0
424,0
0,5
0,0
7,7
0,0
251,0
71,4
85,8
357,5
397,4
330,5
335,5
406,2
222,0
425,0
0,5
0,0
7,7
0,0
252,0
71,5
85,6
357,8
396,8
330,3
335,3
407,8
223,0
426,0
0,5
0,0
7,7
0,0
252,2
71,4
85,3
357,6
396,4
330,0
335,1
408,5
224,0
427,0
0,4
0,0
7,7
0,0
252,0
71,3
85,7
357,4
395,9
330,0
334,7
409,5
225,0
428,0
0,4
0,0
7,6
0,0
252,2
72,0
85,8
356,6
395,3
329,8
334,6
411,0
226,0
429,0
0,4
0,0
7,6
0,0
252,7
72,1
85,7
357,2
395,0
329,5
334,2
410,6
227,0
430,0
0,4
0,0
7,5
0,0
252,4
72,3
85,7
356,9
394,5
329,1
334,1
411,4
228,0
431,0
0,4
0,0
7,5
0,0
252,1
71,9
85,6
357,0
394,1
328,8
333,7
412,1
229,0
432,0
0,4
0,0
7,4
0,0
252,6
71,5
85,8
356,6
393,6
329,0
333,3
413,5
230,0
433,0
0,3
0,0
7,4
0,0
253,1
71,4
85,1
356,4
393,1
328,5
333,3
414,1
231,0
434,0
0,4
0,0
7,4
0,0
253,6
71,4
85,2
356,6
392,7
328,4
333,2
414,0
232,0
435,0
0,3
0,0
7,4
0,0
254,2
71,5
85,1
355,9
392,2
328,3
333,0
414,7
233,0
436,0
0,3
0,0
7,3
0,0
254,0
71,3
85,4
355,6
391,6
328,0
332,8
415,0
234,0
437,0
0,3
0,0
7,2
0,0
253,8
71,3
85,6
355,4
391,2
327,7
332,5
415,1
235,0
438,0
0,3
0,0
7,2
0,0
253,2
71,8
85,5
354,6
390,7
327,4
332,3
416,1
236,0
439,0
0,2
0,0
7,1
0,0
252,9
71,8
85,8
354,6
390,2
327,1
331,7
415,5
237,0
440,0
0,3
0,0
7,1
0,0
252,7
72,2
85,8
354,4
389,7
326,9
331,4
416,0
238,0
441,0
0,2
0,0
7,1
0,0
252,2
72,0
85,4
353,7
389,3
326,5
330,9
415,6
239,0
442,0
0,2
0,0
7,1
0,0
252,2
71,7
85,3
354,1
388,7
326,1
330,6
417,1
240,0
443,0
0,2
0,0
7,1
0,0
251,7
71,8
85,4
352,9
388,2
326,1
330,5
416,6
241,0
444,0
0,2
0,0
7,0
0,0
252,0
71,5
85,5
353,0
387,7
325,7
329,9
417,1
242,0
445,0
0,1
0,0
7,1
0,0
251,7
71,2
85,2
352,5
387,1
325,5
329,6
417,8
243,0
446,0
0,2
0,0
7,1
0,0
251,7
71,5
85,3
352,8
386,6
325,2
329,3
417,8
244,0
447,0
0,1
0,0
7,0
0,0
252,0
71,3
85,2
351,5
386,0
324,9
328,8
418,2
245,0
448,0
0,2
0,0
7,0
0,0
251,8
71,8
85,6
350,8
385,4
324,6
328,4
419,0
246,0
449,0
0,1
0,0
7,0
0,0
251,7
71,7
85,6
350,5
384,9
324,2
327,8
418,3
247,0
450,0
0,1
0,0
7,0
0,0
251,1
72,3
85,3
350,1
384,4
323,7
327,2
418,0
248,0
451,0
0,1
0,0
6,8
0,0
250,5
72,1
85,4
349,8
383,7
323,4
326,7
418,7
249,0
452,0
0,1
0,0
6,7
0,0
250,4
71,8
85,1
349,4
383,2
323,0
326,3
419,6
250,0
453,0
0,1
0,0
6,8
0,0
250,4
71,6
84,6
349,0
382,5
322,8
325,6
419,6
251,0
454,0
0,1
0,0
6,7
0,0
251,0
71,5
84,7
349,0
382,0
322,5
325,2
419,8
252,0
455,0
0,1
0,0
6,7
0,0
251,0
71,6
84,9
348,6
381,3
322,2
325,0
419,7
253,0
456,0
0,0
0,0
6,7
0,0
250,9
71,6
84,3
347,9
380,7
321,8
324,5
419,5
Particulates Calculations
Page 3 of 3
DATA 2018-01-17 EPA PI 20162 RUN 3 CAT 2 MODEL GM 60 NO FAN
Manufacturer: HEARTHSTONE
Model:
GM 60
Overall Heating Efficiency:
79,12%
30,02
Run:
3
Combustion Efficiency:
98,78%
383,40
Project #:
PI 20162
Heat Transfer Efficiency:
80,09%
11,00
Test Duration:
253
min
HHV
LHV
Heat Output:
17 403 Btu/h
18 346 kJ/h
Eff
79,12%
85,51%
Heat Input:
21 997 Btu/h
23 188 kJ/h
Comb Eff
98,78%
98,78%
Ultimate CO2
HT Eff
80,09%
86,57%
CO2-ult
19,64
Burn Duration:
4,22
h
Output
18 346
kJ/h
F0
Burn Rate
1,17
kg/h
1,062
Burn Rate:
2,58
lb/h
1,171
kg/h
Grams CO
100
g
Input
23 188
kJ/h
Stack Temp:
301,2
Deg. F
149,6
Deg. C
MC wet
16,92
Air Fuel Ratio (A/F)
Dry Molecular Weight (Md)
Dry Moles Exhaust Gas (Nr):
Air Fuel Ratio (A/F)
Note: In the “Input data”, "Calc. % O2", "Fuel Properties", and
“Mass Balance” columns, [e], [d], [g], [a]. [b], [c], [h], [u], [w],
[j], and [k] refer to their respective variables in Clauses 13.7.3
CSA B415.1 OE Calculations
Page 1 of 1
DATA 2018-01-18 EPA PI 20162 RUN 4 CAT 3 MODEL GM 60
Paramètres
Tous les facteurs de corrections et autres paramètres qui peuvent être modifiés par
l’utilisateur du fichier sont regroupés ici.
Code verrouillage:
HEA
Description du test
Test standard
EPA
Run #
4
Date
18-01-2018
Technicien
M.M
Project #
PI 20162
Description de l'unité
Manufacturier
HEARTHSTONE
Modèle
GM 60
Combustion system
Cat
Appliance type
WOOD STOVE
Firebox volume
2,03
cu ft.
Appliance weight empty
N.A
lbs
Appliance weight full
N.A
lbs
Paramètres du test
Logging time
1
min
Manufacturer's rated heat output
BTU/h Donnée fournie par le manfacturier
Targeted category
3
Targeted output
N.A
BTU/h
Cp steel
N.A
BTU/lb-°F
Échantillonnage
Blank sampling rate
0,20
cuft/min
Internal probe diameter
0,18
in.
Calibration Factor (DGM #1):
0,988
Dimensionless
Equipment number (DGM #1):
EM 178
Calibration Factor (DGM #2):
0,988
Dimensionless
Equipment number (DGM #2):
EM 179
Calibration Factor (DGM #3):
0,986
Equipment number (DGM #3):
EM 070
Dimensionless
Tunnel
Targeted tunnel flow rate
160
scfm
Tunnel diameter
6
in.
Molecular weight
28,78
May be assumed to be 28,78 (EPA) Si B-415 = 29
Pitot tube type
Standard
Pitot tube coefficient
0,99
Dimensionless
Project nu. PI 20162
Date
18-01-2018
Technicien
M.M
Fuel data
Fuel type
Dimension
Fuel specie
D. Fir
HHV
19810,0 kJ/kg
D. Fir
Oak/Maple
%C
48,7
HHV
19 810
19 887
%H
6,9
%C
48,73
50
%O
43,9
%H
6,87
6,6
%Ash
0,5
%O
43,9
42,9
HHV
8519,2 Btu/lb
%Ash
0,5
0,5
LHV
7451,0 Btu/lb
HHV (Btu/lb)
8519
8552
LHV (Btu/lb)
7451
7480
Default Fuel Values
Paramètres
Page 1 of 1
DATA 2018-01-18 EPA PI 20162 RUN 4 CAT 3 MODEL GM 60
Preload data sheet
Lower
Ideal
Upper
12,79
14,21
15,63
Load Volume:
0,5185
cu. ft
Loading Density:
8,316
lbs./ft3
Number of Spaces:
Load Density (wet):
32,558
lbs./ft3
Spacer weight (lbs):
Dry Wood Density:
26,798899
Weight
Ave. MC x
Volume
Thick Wide x Length
lbs
Weight
Cubic Inches
2
4
8
1,164
20,9
21,3
21,6
21,4
20,8
24,6768
64,00
2
4
8
1,23
20,8
22,3
21,6
22,1
22,6
26,9124
64,00
2
4
8
1,13
20,8
20,4
20,3
20,2
20,2
23,0294
64,00
2
4
8
1,17
20,7
20,7
20,9
21,3
21,5
24,5934
64,00
2
4
8
1,102
22,1
22,3
22,4
22,4
22,5
24,61868
64,00
2
4
8
1,104
23
22,6
22,3
22,1
22
24,7296
64,00
2
4
8
1,222
23,4
23,4
23
22,9
22,6
28,17932
64,00
2
4
8
1,164
21,3
20,7
20,6
20,6
20,4
24,11808
64,00
2
4
8
1,23
20,3
19,9
19,9
20
20,3
24,6984
64,00
2
4
8
1,432
20,6
20,4
20,6
20,8
21
29,61376
64,00
2
4
8
1,284
20,9
20,4
20,6
20,3
20,2
26,29632
64,00
2
4
8
1,174
22
21,4
21,6
21,8
21,3
25,38188
64,00
2
4
8
1,24
22
22,4
22,6
22,3
22
27,6024
64,00
2
4
8
1,236
23
22,9
22,8
23
23
28,35384
64,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
SUM MCx 362,80428
PreTest Load Weight:
16,88
lbs.
Dry Weight:
6,30
kg.
Average Moisture Content: %
Dry:
21,49
21,49
Wet:
17,69
Must be 18-28
must be 15,2-22
Project nu. PI 20162
Date
18-01-2018
Technicien
M.M
Test Load Weight:
Piece Size (in):
Meter Moisture Content
Dry Uncorrected %
Preload Data
Page 1 of 1
Confidentiel
06/02/2018
Page 1
FUEL LOAD DATA SHEET, CSA B415
Lower
Ideal
Upper
12,8
14,2
15,6
* For boilers, a loading density factor of 10 lb/ft3 is applied
Load Volume:
0,43
cu. ft
Loading Density:
6,5
lbs./ft3
Number of Spaces:
12
Load Density (wet):
31,1
lbs./ft3
Spacer weight:
lbs
Dry Wood Density:
25,8
lbs./ft3
Weight
Ave. MC x
Volume
Ave. MC
Thick Wide xLength
lbs
Weight
Cubic Inches
%
1,5
3,5
17,25
1,92
19,60
19,30
19,10
19,30
19,80
37,32524
90,56
19,4
1,5
3,5
17,25
1,92
19,30
19,20
19,20
19,50
19,50
37,17148
90,56
19,3
3,5
3,5
17,25
4,09
21,20
20,90
21,60
21,80
22,00
87,978
211,31
21,5
3,5
3,5
17,25
4,08
20,60
20,00
20,80
20,30
20,80
83,681
211,31
20,5
1,5
0,75
5
0,10
19,10
1,8718
5,63
19,1
1,5
0,75
5
0,11
19,30
2,0844
5,63
19,3
1,5
0,75
5
0,11
20,30
2,3142
5,63
20,3
1,5
0,75
5
0,10
20,60
2,0188
5,63
20,6
1,5
0,75
5
0,10
21,10
2,1522
5,63
21,1
1,5
0,75
5
0,12
21,30
2,4708
5,63
21,3
1,5
0,75
5
0,11
20,60
2,3484
5,63
20,6
1,5
0,75
5
0,09
19,50
1,833
5,63
19,5
1,5
0,75
5
0,11
19,30
2,0458
5,63
19,3
1,5
0,75
5
0,11
21,40
2,2684
5,63
21,4
1,5
0,75
5
0,11
19,80
2,1384
5,63
19,8
1,5
0,75
5
0,09
19,60
1,8424
5,63
19,6
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
SUM MCx 271,54432
20,2 %
Test Load Weight:
13,28
lbs.
Dry Weight:
5,00
kg.
Average Moisture Content: %
Dry:
20,45
Dry(EPA)
20,45
20,45
Wet:
16,98
Dry(B415
20,45
Must be 19-25
must be 15,2-22
Coal Bed Range:
2,7
lbs. to
3,3
lbs.
TEST CHARGE:
Project nu. PI 20162
Coal bed weight:
2,9
lbs.
Date
18-01-2018
Technicien
M.M
Test Load Weight:
Piece Size (in):
Meter Moisture Content
Dry Uncorrected %
Load Data
Page 1 of 1
DATA 2018-01-18 EPA PI 20162 RUN 4 CAT 3 MODEL GM 60
Filter set weight
Ambient
blank (g)
Date
Heure
probe
front
back
gasket
probe
front
back
gasket
probe
front
back
gasket
Filter
Number
16
29
31
11
36
32
33
12
41
35
36
13
37
Before (1)
Before (2)
Before (3)
Before (4)
Before (5)
108,7541
0,1230
0,1296
35,5039
107,7411
0,1290
0,1305
36,0060
110,3645
0,1310
0,1296
35,7031
0,1299
17/01/2018
17:00
Before (6)
108,7542
0,1229
0,1295
35,5040
107,7411
0,1289
0,1306
36,0061
110,3646
0,1311
0,1295
35,7032
0,1300
18/01/2018
09:00
After (1)
108,7549
0,1231
0,1292
35,5068
107,7418
0,1281
0,1299
36,0082
110,3652
0,1316
0,1285
35,7065
0,1302
18/01/2018
15:00
After (2)
108,7542
0,1230
0,1292
35,5067
107,7411
0,1281
0,1299
36,0080
110,3646
0,1316
0,1285
35,7063
0,1301
29/01/2018
08:00
After (3)
108,7542
0,1230
0,1292
35,5067
107,7411
0,1281
0,1299
36,0080
110,3646
0,1316
0,1285
35,7063
0,1301
05/02/2018
08:00
After (4)
After (5)
After (6)
108,7542
0,1230
0,1292
35,5067
107,7411
0,1281
0,1299
36,0080
110,3646
0,1316
0,1285
35,7063
0,1301
05/02/2018
08:00
Difference
0,0000
0,0001
-0,0003
0,0027
0,0000
-0,0008
-0,0007
0,0019
0,0000
0,0005
-0,0010
0,0031
0,0001
Total (mg)
2,5
2,9
2,6
0,1
Total ajusté (mg)
2,40
2,80
2,50
Project nu. PI 20162
Date
18-01-2018
Technicien
M.M
System 2 (g)
System 1 (g) 1st hour
System 1 (g)
Filter set weight
Page 1 of 1
DATA 2018-01-18 EPA PI 20162 RUN 4 CAT 3 MODEL GM 60
SFBA EPA EMISSION RESULTS
RESULTS
Average emission rate:
0,8
g/hr
Burn Rate :
1,604
Dry kg/hr
Test Duration:
187
min
PRESSURE FACTOR:
DGM 1
0,97177
BAROMETRIC PRESSURE
DGM 2
0,96941
Average:
29,884349 in Hg
DGM 3
0,99881
Start:
29,913879 in Hg
End:
29,854819 in Hg
TEMPERATURE FACTORS
DGM 1
0,98393
DGM 2
0,98259
DGM CONTROLLER VALUES
DGM 3
0,98987
DGM 1
Final: 21975,537
Cuft
Initial: 21940,783
Cuft
VOLUMES SAMPLED
DGM 1
32,827
SCft
DGM 2
Final: 19366,735
Cuft
DGM 2
33,546
Scft
Initial: 19331,105
Cuft
DGM 3
22,411
SCft
DGM #3
Final:
740,860
Cuft
Initial:
717,880
Cuft
TOTAL TUNNEL VOLUME :
30883
TEMPERATURES
SAMPLE RATIOS
DGM 1
536,622
°R
Sample Train 1:
940,805
DGM 2
537,358
°R
Sample Train 2:
920,631
CALIBRATION FACTORS
Paticulate concentration
DGM 1
0,9879
Sample Train 1
0,000088
g/dscf
DGM 2
0,9884
Sample Train 2
0,000078
g/dscf
DGM #3
0,9864
Room
0,000004
g/dscf
TUNNEL FLOW RATE:
165,152
Dscfm
TOTAL EMISSIONS
PARTICULATE CATCH
Sample Train 1
2,59
g
Total Sample Train 1:
2,90 mg
Sample Train 2
2,26
g
Total Sample Train 2:
2,60 mg
Total Sample Train 1 1st hour:
2,50 mg
EMISSION RATES
Sample Train 1
0,83
g/hr
Sample Train 2
0,72
g/hr
1st hour emission rate
2,35
g/hr
DEVIATION:
6,91%
Train 1
Train 2
Cs
8,834E-05
7,75058E-05
Particulates Calculations
Page 1 of 1
DATA 2018-01-18 EPA PI 20162 RUN 4 CAT 3 MODEL GM 60
Average
0,13
10,42
#DIV/0!
360,01
73,41
99,40
449,79
306,78
425,15
417,92
485,22
*****
*1
*2
*3
*4
*5
*6
*7
*8
Elapsed
Weight
Flue
Room
Tunnel
Unit
Unit
Unit
Unit
Unit
Time
Raw data row
Remaining
CO
CO2
O2
Gas
Temp
Dry Bulb
Top
Back
R.Side
L.Side
Bottom
min
lbs
%%%
°F
°F
°F
°F
°F
°F
°F
°F
0,00
169,00
13,3
0,0
5,7
0,0
339,8
72,2
131,4
390,0
316,8
427,4
414,8
655,7
1,0
170,0
13,1
0,1
4,0
0,0
365,1
72,4
111,6
386,1
316,5
426,0
413,6
653,2
2,0
171,0
12,9
0,1
9,3
0,0
396,7
72,0
112,1
392,8
314,8
424,7
412,6
648,1
3,0
172,0
12,7
0,1
11,3
0,0
416,2
71,4
113,5
407,9
314,3
423,3
411,7
642,8
4,0
173,0
12,5
0,9
13,8
0,0
433,4
71,5
114,7
426,9
311,9
422,1
410,3
635,9
5,0
174,0
12,4
0,9
15,2
0,0
423,6
72,7
108,5
443,8
310,5
420,9
409,7
630,6
6,0
175,0
12,2
0,3
14,2
0,0
418,0
72,5
107,2
455,4
308,8
419,8
408,6
624,7
7,0
176,0
12,0
0,3
14,5
0,0
416,6
72,4
106,7
466,9
306,3
418,7
407,9
618,9
8,0
177,0
11,8
0,3
14,3
0,0
417,8
72,7
107,1
475,3
305,9
417,3
407,0
613,9
9,0
178,0
11,6
0,3
14,7
0,0
419,0
72,2
107,5
484,0
304,3
416,6
405,7
609,2
10,0
179,0
11,5
0,3
14,7
0,0
420,1
73,0
107,9
491,6
302,9
415,8
405,3
602,2
11,0
180,0
11,3
0,4
14,7
0,0
421,3
73,0
108,1
498,4
300,6
415,2
404,8
596,2
12,0
181,0
11,2
0,4
14,6
0,0
422,1
72,8
108,1
504,8
299,6
414,9
404,4
591,5
13,0
182,0
11,0
0,3
14,5
0,0
422,6
72,6
107,8
511,6
298,6
414,8
404,9
584,8
14,0
183,0
10,9
0,3
14,4
0,0
422,6
72,3
107,6
516,2
298,2
414,6
405,0
579,2
15,0
184,0
10,7
0,3
14,5
0,0
423,7
72,6
108,1
519,9
297,5
414,9
404,9
574,7
16,0
185,0
10,5
0,3
14,6
0,0
425,3
72,8
108,0
524,2
295,7
415,8
405,1
569,5
17,0
186,0
10,4
0,4
14,7
0,0
426,1
72,6
108,2
528,0
295,5
416,5
405,5
563,9
18,0
187,0
10,2
0,4
14,7
0,0
427,8
72,9
108,3
531,9
295,7
417,4
405,9
558,7
19,0
188,0
10,0
0,4
14,8
0,0
429,1
73,3
108,2
536,2
296,0
418,1
406,0
555,5
20,0
189,0
9,9
0,5
14,8
0,0
429,7
73,1
108,6
540,4
295,5
419,6
406,3
549,5
21,0
190,0
9,7
0,4
14,8
0,0
430,2
73,4
109,1
544,0
295,0
420,8
407,1
545,1
22,0
191,0
9,5
0,4
14,8
0,0
429,9
73,5
109,0
547,5
296,0
422,1
407,6
540,1
23,0
192,0
9,4
0,5
14,8
0,0
430,7
73,4
109,0
550,6
296,5
423,2
408,4
536,2
24,0
193,0
9,2
0,5
14,9
0,0
432,2
73,3
109,2
553,4
295,1
425,0
409,2
531,6
25,0
194,0
9,1
0,7
15,1
0,0
433,8
73,6
110,1
558,3
297,1
426,3
410,0
527,1
26,0
195,0
8,9
0,8
15,2
0,0
436,1
73,8
110,1
562,8
297,0
428,1
411,0
523,3
27,0
196,0
8,7
0,9
15,3
0,0
437,2
73,2
110,1
567,2
297,7
429,6
412,1
519,4
28,0
197,0
8,6
1,0
15,3
0,0
437,0
74,0
109,9
571,4
298,7
431,3
413,2
514,7
29,0
198,0
8,4
1,0
15,4
0,0
437,7
74,0
110,0
574,4
298,4
433,2
414,3
511,0
30,0
199,0
8,2
1,0
15,3
0,0
438,1
73,7
109,5
577,6
298,4
434,8
415,6
507,4
31,0
200,0
8,1
0,9
15,3
0,0
439,2
73,2
109,4
579,9
298,6
436,4
416,5
504,8
32,0
201,0
7,9
0,9
15,2
0,0
439,3
74,0
109,9
582,1
299,7
438,5
418,1
501,3
33,0
202,0
7,7
0,7
15,4
0,0
439,8
74,1
110,2
582,3
301,4
440,1
418,7
498,2
34,0
203,0
7,6
0,6
15,5
0,0
440,1
74,2
110,2
584,4
301,9
441,8
420,4
495,1
35,0
204,0
7,5
0,5
15,5
0,0
440,9
73,5
110,1
585,6
302,0
443,5
421,6
492,2
36,0
205,0
7,3
0,5
15,6
0,0
441,5
74,2
110,1
586,2
302,5
444,9
422,8
488,8
37,0
206,0
7,2
0,4
15,7
0,0
442,1
74,1
109,9
587,4
304,0
446,6
424,5
486,4
38,0
207,0
7,1
0,3
15,6
0,0
441,9
73,7
109,9
588,1
304,3
448,4
425,4
483,5
39,0
208,0
6,9
0,3
15,5
0,0
442,1
73,8
109,8
589,5
306,1
450,0
426,9
480,3
40,0
209,0
6,8
0,3
15,5
0,0
442,5
73,3
109,8
589,3
306,2
451,8
428,2
478,7
41,0
210,0
6,6
0,3
15,5
0,0
443,0
74,0
109,8
590,5
308,0
453,6
429,9
475,4
42,0
211,0
6,5
0,3
15,5
0,0
441,9
73,6
109,6
589,9
308,7
455,6
431,2
473,3
43,0
212,0
6,3
0,3
15,5
0,0
441,8
73,7
109,7
589,5
309,9
457,3
432,5
470,9
44,0
213,0
6,2
0,2
15,5
0,0
440,1
74,8
109,9
590,1
310,3
459,3
433,9
468,6
45,0
214,0
6,1
0,1
15,4
0,0
438,5
74,4
109,8
588,7
311,5
460,7
435,4
466,7
46,0
215,0
5,9
0,1
15,4
0,0
437,5
74,2
109,9
587,9
312,1
462,6
437,0
464,5
47,0
216,0
5,8
0,1
15,3
0,0
436,7
74,6
109,4
587,4
313,4
464,2
438,6
462,1
48,0
217,0
5,7
0,1
15,4
0,0
436,7
74,4
109,6
587,0
315,0
465,8
439,9
460,5
49,0
218,0
5,5
0,2
15,4
0,0
436,0
74,4
109,2
585,9
315,9
467,1
441,2
458,4
50,0
219,0
5,4
0,1
15,4
0,0
435,7
73,9
108,9
585,9
316,8
468,6
442,8
456,6
51,0
220,0
5,3
0,1
15,1
0,0
434,1
74,0
108,3
586,1
318,7
469,9
444,4
454,9
52,0
221,0
5,2
0,0
14,8
0,0
431,6
74,5
108,1
585,4
320,3
471,0
446,0
453,4
53,0
222,0
5,0
0,0
14,5
0,0
428,8
73,8
107,8
583,4
321,8
472,2
447,3
451,4
54,0
223,0
4,9
0,0
14,1
0,0
425,3
74,4
107,3
581,9
322,9
473,3
448,7
450,7
55,0
224,0
4,8
0,0
13,7
0,0
421,1
75,1
106,8
578,9
324,7
474,0
449,8
448,3
56,0
225,0
4,8
0,0
13,5
0,0
417,6
75,3
107,0
575,7
325,3
474,8
450,7
447,2
57,0
226,0
4,6
0,0
13,2
0,0
414,4
75,1
106,6
573,1
327,2
475,4
451,3
445,7
58,0
227,0
4,5
0,0
13,2
0,0
412,1
74,8
106,3
570,1
329,5
475,9
452,4
444,3
59,0
228,0
4,4
0,0
13,2
0,0
410,5
74,1
106,1
566,9
330,6
476,3
453,2
443,7
60,0
229,0
4,3
0,0
13,2
0,0
408,9
74,5
105,6
565,0
331,3
476,5
454,0
442,2
61,0
230,0
4,2
0,0
13,0
0,0
406,4
75,0
105,5
562,0
332,4
476,4
454,6
441,4
62,0
231,0
4,1
0,0
12,8
0,0
405,0
74,4
105,1
559,7
333,9
476,3
455,1
440,3
63,0
232,0
4,1
0,0
12,8
0,0
402,9
74,4
104,6
556,4
334,4
475,8
455,9
439,5
64,0
233,0
4,0
0,0
12,7
0,0
400,8
74,8
104,4
554,4
335,8
475,3
456,4
438,7
65,0
234,0
3,9
0,0
12,6
0,0
399,0
74,7
104,1
552,0
336,6
474,8
457,1
437,9
66,0
235,0
3,8
0,0
12,6
0,0
397,2
74,8
103,4
548,5
337,9
473,9
457,3
437,1
67,0
236,0
3,7
0,0
12,4
0,0
394,3
74,8
103,6
546,7
337,9
473,1
457,8
436,4
68,0
237,0
3,6
0,0
12,3
0,0
392,0
74,6
103,9
543,6
338,3
472,2
458,7
436,5
69,0
238,0
3,6
0,0
12,2
0,0
389,5
75,0
103,5
541,5
338,6
471,0
459,1
435,5
70,0
239,0
3,5
0,0
12,0
0,0
387,1
74,0
103,2
538,5
338,8
470,0
459,5
434,8
71,0
240,0
3,4
0,0
11,8
0,0
384,9
75,1
102,9
535,0
339,5
468,6
459,9
434,2
72,0
241,0
3,3
0,0
11,7
0,0
382,5
74,3
102,3
530,4
340,5
467,5
460,4
433,5
73,0
242,0
3,3
0,0
11,6
0,0
379,9
74,0
102,0
527,6
340,9
466,5
460,5
433,7
74,0
243,0
3,2
0,0
11,5
0,0
378,2
73,8
101,8
523,5
341,2
465,2
460,7
433,7
75,0
244,0
3,1
0,0
11,3
0,0
376,3
74,7
101,7
520,2
341,7
464,0
460,5
433,0
76,0
245,0
3,0
0,0
11,4
0,0
374,5
74,4
101,4
516,2
341,0
462,9
460,8
432,3
77,0
246,0
3,0
0,0
11,4
0,0
372,8
74,9
101,1
512,0
341,7
462,0
460,4
432,5
78,0
247,0
2,9
0,0
11,5
0,0
371,3
74,8
100,8
510,1
341,8
461,2
460,4
431,8
79,0
248,0
2,9
0,0
11,7
0,0
369,7
74,5
100,9
508,4
343,0
460,3
460,2
432,2
80,0
249,0
2,8
0,0
11,8
0,0
367,9
75,0
101,1
506,5
343,5
459,5
460,0
431,3
81,0
250,0
2,7
0,0
11,7
0,0
365,7
74,4
100,4
503,5
343,8
458,8
459,8
431,5
82,0
251,0
2,6
0,0
11,3
0,0
363,7
74,4
99,8
500,3
345,2
458,1
459,4
431,2
83,0
252,0
2,6
0,0
10,8
0,0
361,9
73,9
99,6
496,9
345,2
457,6
459,1
430,7
84,0
253,0
2,5
0,0
10,7
0,0
359,8
74,4
99,3
494,0
345,7
456,9
458,6
430,4
85,0
254,0
2,5
0,0
10,6
0,0
358,0
73,9
98,9
490,2
346,2
456,1
458,2
430,2
86,0
255,0
2,4
0,0
10,4
0,0
356,3
73,9
98,7
487,0
346,4
455,4
457,8
430,2
87,0
256,0
2,4
0,0
10,2
0,0
354,1
73,1
98,2
482,2
347,3
454,7
457,1
430,1
88,0
257,0
2,3
0,0
10,1
0,0
352,6
73,1
97,8
478,7
346,9
454,0
456,8
430,3
89,0
258,0
2,3
0,0
10,0
0,0
349,8
73,7
97,6
475,4
347,2
453,4
456,4
430,5
90,0
259,0
2,2
0,0
9,9
0,0
348,8
73,9
97,6
472,0
347,1
452,6
455,7
431,4
91,0
260,0
2,2
0,0
9,5
0,0
346,5
74,5
97,4
468,0
345,9
451,9
455,5
431,2
92,0
261,0
2,2
0,0
9,2
0,0
344,4
74,1
97,3
464,5
347,9
450,8
455,0
431,4
93,0
262,0
2,1
0,0
9,0
0,0
342,7
73,9
97,3
460,3
346,3
450,0
454,4
432,1
94,0
263,0
2,1
0,0
8,6
0,0
340,9
73,9
97,1
455,4
345,9
449,2
453,7
432,3
95,0
264,0
2,1
0,0
8,6
0,0
339,2
73,8
96,5
451,1
345,0
447,8
453,0
432,8
96,0
265,0
2,0
0,0
8,5
0,0
338,3
73,7
96,2
447,2
343,0
446,4
452,4
434,0
97,0
266,0
2,0
0,0
8,2
0,0
337,1
74,1
96,0
443,3
343,0
445,5
451,5
435,5
98,0
267,0
2,0
0,0
8,0
0,0
336,6
74,2
95,4
439,7
340,8
444,6
450,5
436,5
99,0
268,0
2,0
0,0
7,9
0,0
335,2
73,6
95,3
435,6
339,6
443,5
449,5
437,4
100,0
269,0
1,9
0,0
7,9
0,0
333,5
73,6
95,0
432,4
339,2
442,5
448,5
438,8
Particulates Calculations
Page 1 of 2
DATA 2018-01-18 EPA PI 20162 RUN 4 CAT 3 MODEL GM 60
101,0
270,0
1,9
0,0
7,9
0,0
333,2
74,2
94,7
428,2
337,5
441,0
447,2
440,8
102,0
271,0
1,9
0,0
7,9
0,0
331,8
73,9
95,1
424,7
336,1
439,8
445,7
441,3
103,0
272,0
1,9
0,0
7,9
0,0
331,1
74,1
95,4
421,0
334,6
438,6
445,0
442,8
104,0
273,0
1,9
0,0
7,9
0,0
329,5
74,0
95,0
418,0
332,3
437,3
443,4
443,5
105,0
274,0
1,8
0,0
7,9
0,0
328,9
73,6
94,7
414,3
330,9
436,2
442,0
444,6
106,0
275,0
1,8
0,0
8,0
0,0
327,8
73,8
94,5
411,6
327,7
434,8
440,3
445,7
107,0
276,0
1,8
0,0
8,0
0,0
327,4
73,3
94,3
408,7
326,9
433,7
439,0
446,5
108,0
277,0
1,8
0,0
8,0
0,0
326,0
73,2
94,0
405,9
325,5
432,7
437,5
447,4
109,0
278,0
1,7
0,0
8,1
0,0
325,1
73,6
93,9
403,3
323,6
431,3
436,0
448,1
110,0
279,0
1,7
0,0
8,1
0,0
324,3
72,7
93,8
401,2
321,3
430,1
434,2
449,4
111,0
280,0
1,7
0,0
8,1
0,0
323,6
72,7
93,5
398,9
319,2
428,8
432,9
449,6
112,0
281,0
1,6
0,0
8,2
0,0
322,7
73,6
93,2
396,1
318,0
427,4
431,1
451,0
113,0
282,0
1,6
0,0
8,2
0,0
321,6
73,6
93,7
393,5
316,7
426,3
430,0
450,9
114,0
283,0
1,6
0,0
8,2
0,0
320,6
73,4
93,9
391,8
315,4
424,9
428,3
452,8
115,0
284,0
1,6
0,0
8,2
0,0
320,2
72,5
93,5
389,8
315,6
423,7
426,9
453,5
116,0
285,0
1,6
0,0
8,2
0,0
319,6
73,6
93,5
387,7
313,7
422,7
425,4
454,1
117,0
286,0
1,5
0,0
8,1
0,0
318,7
73,0
93,3
386,5
311,9
421,5
424,0
454,8
118,0
287,0
1,5
0,0
8,2
0,0
318,1
73,2
93,3
384,5
311,0
420,0
422,8
455,4
119,0
288,0
1,5
0,0
8,2
0,0
317,9
73,6
92,9
382,4
309,9
418,8
421,2
456,3
120,0
289,0
1,5
0,0
8,2
0,0
317,5
73,7
92,8
381,4
308,7
417,7
420,1
457,7
121,0
290,0
1,4
0,0
8,1
0,0
316,7
73,0
92,6
379,5
307,6
416,5
419,0
458,1
122,0
291,0
1,4
0,0
8,1
0,0
316,7
73,3
92,3
377,9
307,0
415,4
417,6
459,8
123,0
292,0
1,4
0,0
8,1
0,0
316,0
73,3
92,8
376,5
305,5
414,3
416,3
459,7
124,0
293,0
1,3
0,0
8,0
0,0
315,4
73,4
93,0
374,7
304,9
413,2
415,1
461,2
125,0
294,0
1,3
0,0
8,0
0,0
315,1
72,8
92,6
373,3
304,7
412,0
413,9
460,8
126,0
295,0
1,3
0,0
7,9
0,0
315,1
73,1
92,6
372,4
303,9
411,1
412,9
462,0
127,0
296,0
1,2
0,0
7,8
0,0
314,4
73,1
92,6
370,5
302,9
410,2
411,6
462,4
128,0
297,0
1,3
0,0
7,9
0,0
313,9
73,2
92,1
369,6
302,4
408,8
410,4
463,8
129,0
298,0
1,2
0,0
7,9
0,0
312,9
73,2
92,4
368,6
301,6
407,9
409,3
463,9
130,0
299,0
1,2
0,0
8,0
0,0
312,5
73,5
92,0
367,7
301,4
406,7
408,0
464,8
131,0
300,0
1,2
0,0
7,9
0,0
311,4
73,6
92,0
366,6
300,6
405,7
406,9
465,2
132,0
301,0
1,2
0,0
7,7
0,0
310,9
73,4
91,6
366,0
300,0
404,8
405,7
466,9
133,0
302,0
1,2
0,0
7,7
0,0
310,0
72,8
92,4
364,9
299,9
404,0
404,5
466,2
134,0
303,0
1,1
0,0
7,7
0,0
309,0
73,0
92,7
363,4
298,7
403,2
403,9
468,9
135,0
304,0
1,1
0,0
7,7
0,0
308,4
72,9
92,5
362,7
297,7
402,6
402,4
468,9
136,0
305,0
1,1
0,0
7,8
0,0
308,0
72,7
92,0
361,3
297,0
401,8
401,1
471,6
137,0
306,0
1,1
0,0
7,8
0,0
307,5
72,9
92,0
360,5
296,2
401,1
400,2
472,1
138,0
307,0
1,0
0,0
7,8
0,0
306,8
72,5
91,7
359,4
294,7
400,6
399,1
473,3
139,0
308,0
1,0
0,0
7,8
0,0
306,7
72,1
91,7
358,9
294,3
399,9
398,0
474,6
140,0
309,0
1,0
0,0
7,7
0,0
306,6
72,6
91,6
357,9
293,6
399,4
396,8
476,1
141,0
310,0
1,0
0,0
7,7
0,0
306,2
72,9
91,5
357,1
291,5
398,8
395,9
477,4
142,0
311,0
1,0
0,0
7,7
0,0
306,7
72,5
91,4
356,2
291,4
398,3
394,9
478,5
143,0
312,0
0,9
0,0
7,8
0,0
306,4
72,7
91,6
355,5
290,4
397,7
393,9
480,5
144,0
313,0
0,9
0,0
7,7
0,0
305,9
73,2
91,7
354,6
288,2
397,1
393,1
480,8
145,0
314,0
0,9
0,0
7,8
0,0
305,5
73,3
91,8
354,0
288,3
396,4
392,0
482,1
146,0
315,0
0,8
0,0
7,8
0,0
305,2
73,0
91,6
353,5
287,3
396,1
391,3
483,9
147,0
316,0
0,8
0,0
7,7
0,0
305,6
72,6
91,8
352,8
286,2
395,3
390,5
485,1
148,0
317,0
0,8
0,0
7,8
0,0
305,6
72,6
91,7
352,2
285,1
394,9
389,7
486,4
149,0
318,0
0,8
0,0
7,6
0,0
306,3
72,2
91,2
352,0
283,9
394,4
389,0
486,8
150,0
319,0
0,8
0,0
7,6
0,0
306,1
72,5
91,4
351,0
282,9
393,8
388,0
488,0
151,0
320,0
0,7
0,0
7,5
0,0
306,4
72,0
91,2
350,7
282,1
393,2
387,3
488,4
152,0
321,0
0,7
0,0
7,5
0,0
306,3
72,5
91,1
349,3
282,0
392,5
386,6
489,6
153,0
322,0
0,7
0,0
7,5
0,0
306,4
72,9
91,2
348,9
280,5
391,7
385,9
492,0
154,0
323,0
0,7
0,0
7,5
0,0
306,8
72,7
91,6
348,3
280,2
390,9
385,1
491,3
155,0
324,0
0,7
0,0
7,4
0,0
306,3
73,1
91,9
347,1
279,1
390,1
384,5
492,9
156,0
325,0
0,6
0,0
7,4
0,0
306,7
73,2
91,8
346,3
277,5
389,3
383,7
493,5
157,0
326,0
0,6
0,0
7,2
0,0
306,7
72,7
91,6
345,5
278,0
388,7
383,1
494,3
158,0
327,0
0,6
0,0
7,1
0,0
306,0
72,9
91,5
345,2
276,4
387,8
382,3
494,6
159,0
328,0
0,6
0,0
7,0
0,0
306,2
72,7
91,3
343,9
275,6
386,9
381,3
495,4
160,0
329,0
0,5
0,0
7,0
0,0
305,7
73,7
91,2
343,0
275,0
385,9
380,4
496,2
161,0
330,0
0,5
0,0
7,0
0,0
306,0
72,8
91,2
342,4
275,0
385,4
379,9
497,4
162,0
331,0
0,5
0,0
7,0
0,0
305,8
72,9
91,0
341,8
273,6
384,5
378,9
497,9
163,0
332,0
0,5
0,0
7,0
0,0
305,7
73,0
91,1
340,9
272,7
383,6
378,3
498,7
164,0
333,0
0,5
0,0
7,0
0,0
305,5
72,9
90,9
340,1
271,6
382,5
377,0
499,8
165,0
334,0
0,4
0,0
7,0
0,0
305,7
72,7
91,7
339,2
270,9
381,7
376,4
500,0
166,0
335,0
0,4
0,0
7,1
0,0
305,2
72,8
92,1
338,7
270,5
380,8
375,4
502,0
167,0
336,0
0,4
0,0
7,1
0,0
305,0
72,9
91,8
337,7
269,1
380,0
374,7
502,0
168,0
337,0
0,4
0,0
6,9
0,0
304,6
72,8
91,4
337,1
268,8
379,1
373,9
503,1
169,0
338,0
0,4
0,0
6,8
0,0
304,4
72,9
91,3
336,2
267,5
378,2
373,1
504,3
170,0
339,0
0,4
0,0
6,8
0,0
304,6
72,5
91,2
335,6
266,5
377,3
372,2
504,9
171,0
340,0
0,3
0,0
6,8
0,0
304,5
72,3
91,2
335,1
265,7
376,3
371,4
506,6
172,0
341,0
0,3
0,0
6,8
0,0
304,1
72,5
91,0
334,3
265,4
375,2
370,6
508,2
173,0
342,0
0,3
0,0
6,8
0,0
304,5
72,6
91,0
333,7
264,0
374,4
369,6
508,8
174,0
343,0
0,3
0,0
7,1
0,0
303,0
72,1
90,7
332,8
262,9
373,4
368,9
510,1
175,0
344,0
0,2
0,0
7,1
0,0
301,0
72,7
90,5
332,0
262,6
372,3
367,7
512,2
176,0
345,0
0,2
0,0
6,7
0,0
298,7
72,5
91,3
330,9
262,9
371,0
367,1
513,2
177,0
346,0
0,2
0,0
6,6
0,0
296,4
72,8
91,3
330,2
261,4
369,9
366,3
515,6
178,0
347,0
0,2
0,0
6,6
0,0
294,5
72,5
91,0
328,8
261,0
369,0
365,5
516,9
179,0
348,0
0,2
0,0
6,5
0,0
293,6
72,3
90,7
328,1
260,7
368,2
364,5
518,8
180,0
349,0
0,1
0,0
6,5
0,0
292,8
72,4
90,6
326,7
258,6
367,0
363,6
520,4
181,0
350,0
0,1
0,0
6,4
0,0
291,4
72,4
90,3
325,7
258,9
365,9
362,7
522,0
182,0
351,0
0,1
0,0
6,5
0,0
291,1
72,6
90,2
324,4
257,9
364,6
361,7
524,8
183,0
352,0
0,1
0,0
6,4
0,0
291,1
72,2
90,1
323,2
257,5
363,8
360,7
527,1
184,0
353,0
0,1
0,0
6,4
0,0
290,6
72,4
90,0
322,0
256,3
362,9
360,0
528,5
185,0
354,0
0,1
0,0
6,4
0,0
290,3
72,6
89,6
320,6
256,6
362,1
359,1
529,7
186,0
355,0
0,1
0,0
6,3
0,0
290,3
72,4
90,1
319,9
254,8
360,9
358,0
532,6
187,0
356,0
0,0
0,0
6,3
0,0
289,5
72,5
90,3
318,7
255,3
360,0
357,5
533,6
Particulates Calculations
Page 2 of 2
DATA 2018-01-18 EPA PI 20162 RUN 4 CAT 3 MODEL GM 60
Manufacturer: HEARTHSTONE
Model:
GM 60
Overall Heating Efficiency:
77,81%
30,06
Run:
4
Combustion Efficiency:
98,69%
371,81
Project #:
PI 20162
Heat Transfer Efficiency:
78,85%
10,67
Test Duration: 187
min
HHV
LHV
Heat Output:
23 468 Btu/h
24 740 kJ/h
Eff
77,81%
84,10%
Heat Input:
30 161 Btu/h
31 795 kJ/h
Comb Eff
98,69%
98,69%
Ultimate CO2
HT Eff
78,85%
85,22%
CO2-ult
19,64
Burn Duration:
3,12
h
Output
24 740
kJ/h
F0
Burn Rate
1,61
kg/h
1,062
Burn Rate:
3,54
lb/h
1,605
kg/h
Grams CO
102
g
Input
31 795
kJ/h
Stack Temp:
360,1
Deg. F
182,3
Deg. C
MC wet
16,98
Air Fuel Ratio (A/F)
Dry Molecular Weight (Md)
Dry Moles Exhaust Gas (Nr):
Air Fuel Ratio (A/F)
Note: In the “Input data”, "Calc. % O2", "Fuel Properties", and
“Mass Balance” columns, [e], [d], [g], [a]. [b], [c], [h], [u], [w],
[j], and [k] refer to their respective variables in Clauses 13.7.3
CSA B415.1 OE Calculations
Page 1 of 1
DATA 2018-01-22 EPA PI 20162 RUN 5 CAT 4 MODEL GM 60
Paramètres
Tous les facteurs de corrections et autres paramètres qui peuvent être modifiés par
l’utilisateur du fichier sont regroupés ici.
Code verrouillage:
HEA
Description du test
Test standard
EPA
Run #
5
Date
22-01-2018
Technicien
M.M
Project #
PI 20162
Description de l'unité
Manufacturier
HEARTHSTONE
Modèle
GM 60
Combustion system
Cat
Appliance type
WOOD STOVE
Firebox volume
2,03
cu ft.
Appliance weight empty
N.A
lbs
Appliance weight full
N.A
lbs
Paramètres du test
Logging time
1
min
Manufacturer's rated heat output
BTU/h Donnée fournie par le manfacturier
Targeted category
4
Targeted output
N.A
BTU/h
Cp steel
N.A
BTU/lb-°F
Échantillonnage
Blank sampling rate
0,20
cuft/min
Internal probe diameter
0,18
in.
Calibration Factor (DGM #1):
0,988
Dimensionless
Equipment number (DGM #1):
EM 178
Calibration Factor (DGM #2):
0,988
Dimensionless
Equipment number (DGM #2):
EM 179
Calibration Factor (DGM #3):
0,986
Equipment number (DGM #3):
EM 070
Dimensionless
Tunnel
Targeted tunnel flow rate
150
scfm
Tunnel diameter
6
in.
Molecular weight
28,78
May be assumed to be 28,78 (EPA) Si B-415 = 29
Pitot tube type
Standard
Pitot tube coefficient
0,99
Dimensionless
Project nu. PI 20162
Date
22-01-2018
Technicien
M.M
Fuel data
Fuel type
Dimension
Fuel specie
D. Fir
HHV
19810,0 kJ/kg
D. Fir
Oak/Maple
%C
48,7
HHV
19 810
19 887
%H
6,9
%C
48,73
50
%O
43,9
%H
6,87
6,6
%Ash
0,5
%O
43,9
42,9
HHV
8519,2 Btu/lb
%Ash
0,5
0,5
LHV
7451,0 Btu/lb
HHV (Btu/lb)
8519
8552
LHV (Btu/lb)
7451
7480
Default Fuel Values
Paramètres
Page 1 of 1
DATA 2018-01-22 EPA PI 20162 RUN 5 CAT 4 MODEL GM 60
Preload data sheet
Lower
Ideal
Upper
12,79
14,21
15,63
Load Volume:
0,5185
cu. ft
Loading Density:
7,625
lbs./ft3
Number of Spaces:
Load Density (wet):
29,850
lbs./ft3
Spacer weight (lbs):
Dry Wood Density:
24,398795
Weight
Ave. MC x
Volume
Thick Wide x Length
lbs
Weight
Cubic Inches
2
4
8
1,038
22,3
22,6
23
23,1
23,4
23,74944
64,00
2
4
8
1,008
21,9
21,6
21,8
21,9
21,3
21,8736
64,00
2
4
8
1,46
23
23,3
22,9
22,6
22,8
33,4632
64,00
2
4
8
1,21
23,1
23,4
23,6
23,1
23,6
28,2656
64,00
2
4
8
1,074
22,9
22,5
22,3
22,8
22,4
24,25092
64,00
2
4
8
1,05
22,6
22,9
21,8
21,3
21,9
23,205
64,00
2
4
8
1,096
22,3
22,4
22,3
21,9
21,5
24,19968
64,00
2
4
8
1,008
22,8
22,5
22,3
22
22,4
22,5792
64,00
2
4
8
1,016
21,6
21,8
21,9
21,5
21,4
21,98624
64,00
2
4
8
1,13
23
22,6
22,8
22,4
22,3
25,5606
64,00
2
4
8
1,046
21,3
21,2
21,6
21,9
21,4
22,46808
64,00
2
4
8
1,178
22,8
22,3
22,9
22,8
22,9
26,78772
64,00
2
4
8
1,068
23
23,4
22,6
22,9
23
24,54264
64,00
2
4
8
1,096
21,4
20,6
20,8
20,9
20,8
22,9064
64,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
SUM MCx 345,83832
PreTest Load Weight:
15,48
lbs.
Dry Weight:
5,74
kg.
Average Moisture Content: %
Dry:
22,34
22,34
Wet:
18,26
Must be 18-28
must be 15,2-22
Project nu. PI 20162
Date
22-01-2018
Technicien
M.M
Test Load Weight:
Piece Size (in):
Meter Moisture Content
Dry Uncorrected %
Preload Data
Page 1 of 1
Confidentiel
06/02/2018
Page 1
FUEL LOAD DATA SHEET, CSA B415
Lower
Ideal
Upper
12,8
14,2
15,6
* For boilers, a loading density factor of 10 lb/ft3 is applied
Load Volume:
0,42
cu. ft
Loading Density:
6,7
lbs./ft3
Number of Spaces:
12
Load Density (wet):
32,2
lbs./ft3
Spacer weight:
lbs
Dry Wood Density:
26,8
lbs./ft3
Weight
Ave. MC x
Volume
Ave. MC
Thick Wide xLength
lbs
Weight
Cubic Inches
%
1,5
3,5
17
1,77
20,70
20,50
20,20
20,10
20,90
36,2496
89,25
20,5
1,5
3,5
17
1,74
20,10
20,60
20,30
20,20
20,10
35,21188
89,25
20,3
3,5
3,5
17
4,70
19,60
19,90
20,10
19,50
19,50
92,64456
208,25
19,7
3,5
3,5
17
4,03
19,90
20,00
19,80
19,60
20,10
80,1164
208,25
19,9
1,5
0,75
5
0,12
20,40
2,4072
5,63
20,4
1,5
0,75
5
0,11
20,60
2,3072
5,63
20,6
1,5
0,75
5
0,11
20,80
2,2048
5,63
20,8
1,5
0,75
5
0,12
20,90
2,5498
5,63
20,9
1,5
0,75
5
0,12
20,40
2,4888
5,63
20,4
1,5
0,75
5
0,12
20,30
2,3548
5,63
20,3
1,5
0,75
5
0,11
20,90
2,299
5,63
20,9
1,5
0,75
5
0,10
21,00
2,184
5,63
21,0
1,5
0,75
5
0,11
21,10
2,2788
5,63
21,1
1,5
0,75
5
0,11
20,60
2,1836
5,63
20,6
1,5
0,75
5
0,11
20,80
2,2048
5,63
20,8
1,5
0,75
5
0,12
20,40
2,4888
5,63
20,4
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
SUM MCx 272,17404
20,5 %
Test Load Weight:
13,59
lbs.
Dry Weight:
5,13
kg.
Average Moisture Content: %
Dry:
20,03
Dry(EPA)
20,03
20,03
Wet:
16,69
Dry(B415
20,03
Must be 19-25
must be 15,2-22
Coal Bed Range:
2,7
lbs. to
3,4
lbs.
TEST CHARGE:
Project nu. PI 20162
Coal bed weight:
2,7
lbs.
Date
22-01-2018
Technicien
M.M
Test Load Weight:
Piece Size (in):
Meter Moisture Content
Dry Uncorrected %
Load Data
Page 1 of 1
DATA 2018-01-22 EPA PI 20162 RUN 5 CAT 4 MODEL GM 60
Filter set weight
Ambient
blank (g)
Date
Heure
probe
front
back
gasket
probe
front
back
gasket
probe
front
back
gasket
Filter
Number
13
3016
34
14
32
38
39
15
33
40
41
27
42
Before (1)
Before (2)
Before (3)
Before (4)
Before (5)
95,1503
0,1281
0,1294
35,2240
110,1770
0,1280
0,1261
35,4866
109,3623
0,1280
0,1241
35,1025
0,1252
18/01/2018
18:00
Before (6)
95,1504
0,1282
0,1293
35,2239
110,1771
0,1279
0,1260
35,4867
109,3623
0,1280
0,1242
35,1026
0,1253
22/01/2018
09:00
After (1)
95,1532
0,1301
0,1293
35,2257
110,1783
0,1276
0,1255
35,4885
109,3638
0,1304
0,1239
35,1046
0,1253
22/01/2018
14:00
After (2)
95,1521
0,1299
0,1293
35,2254
110,1775
0,1275
0,1255
35,4881
109,3631
0,1304
0,1239
35,1042
0,1253
29/01/2018
08:00
After (3)
95,1520
0,1298
0,1293
35,2254
110,1774
0,1275
0,1254
35,4880
109,3631
0,1305
0,1240
35,1043
0,1253
01/02/2018
08:00
After (4)
After (5)
After (6)
95,1520
0,1298
0,1293
35,2254
110,1774
0,1275
0,1254
35,4880
109,3631
0,1305
0,1240
35,1043
0,1253
01/02/2018
08:00
Difference
0,0016
0,0016
0,0000
0,0015
0,0003
-0,0004
-0,0006
0,0013
0,0008
0,0025
-0,0002
0,0017
0,0000
Total (mg)
4,7
5,3
4,8
0
Total ajusté (mg)
4,70
5,30
4,80
Project nu. PI 20162
Date
22-01-2018
Technicien
mm
System 2 (g)
System 1 (g) 1st hour
System 1 (g)
Filter set weight
Page 1 of 1
DATA 2018-01-22 EPA PI 20162 RUN 5 CAT 4 MODEL GM 60
SFBA EPA EMISSION RESULTS
RESULTS
Average emission rate:
2,2
g/hr
Burn Rate :
2,370
Dry kg/hr
Test Duration:
130
min
PRESSURE FACTOR:
DGM 1
0,98022
BAROMETRIC PRESSURE
DGM 2
0,97511
Average:
30,223944 in Hg
DGM 3
1,01016
Start:
30,268239 in Hg
End:
30,179649 in Hg
TEMPERATURE FACTORS
DGM 1
0,98391
DGM 2
0,98236
DGM CONTROLLER VALUES
DGM 3
0,99105
DGM 1
Final: 21999,115
Cuft
Initial: 21975,620
Cuft
VOLUMES SAMPLED
DGM 1
22,384
SCft
DGM 2
Final: 19390,979
Cuft
DGM 2
22,838
Scft
Initial: 19366,859
Cuft
DGM 3
15,790
SCft
DGM #3
Final:
756,840
Cuft
Initial:
740,850
Cuft
TOTAL TUNNEL VOLUME :
20878
TEMPERATURES
SAMPLE RATIOS
DGM 1
536,636
°R
Sample Train 1:
932,686
DGM 2
537,480
°R
Sample Train 2:
914,141
CALIBRATION FACTORS
Paticulate concentration
DGM 1
0,9879
Sample Train 1
0,000237
g/dscf
DGM 2
0,9884
Sample Train 2
0,000210
g/dscf
DGM #3
0,9864
Room
0,000000
g/dscf
TUNNEL FLOW RATE:
160,597
Dscfm
TOTAL EMISSIONS
PARTICULATE CATCH
Sample Train 1
4,94
g
Total Sample Train 1:
5,30 mg
Sample Train 2
4,39
g
Total Sample Train 2:
4,80 mg
Total Sample Train 1 1st hour:
4,70 mg
EMISSION RATES
Sample Train 1
2,28
g/hr
Sample Train 2
2,03
g/hr
1st hour emission rate
4,38
g/hr
DEVIATION:
5,95%
Train 1
Train 2
Cs
0,0002368 0,000210171
Particulates Calculations
Page 1 of 1
DATA 2018-01-22 EPA PI 20162 RUN 5 CAT 4 MODEL GM 60
Average
0,17
11,38
#DIV/0!
455,41
72,77
117,05
561,43
353,92
486,78
458,76
505,43
*****
*1
*2
*3
*4
*5
*6
*7
*8
Elapsed
Weight
Flue
Room
Tunnel
Unit
Unit
Unit
Unit
Unit
Time
Raw data row
Remaining
CO
CO2
O2
Gas
Temp
Dry Bulb
Top
Back
R.Side
L.Side
Bottom
min
lbs
%%%
°F
°F
°F
°F
°F
°F
°F
°F
0,00
157,00
13,6
0,0
6,9
0,0
419,1
71,4
165,5
510,6
347,3
440,1
416,5
672,2
1,0
158,0
13,4
0,1
5,6
0,0
430,5
71,5
125,6
501,7
347,9
440,6
417,3
669,0
2,0
159,0
13,2
0,0
9,5
0,0
442,9
71,1
122,6
503,4
348,7
441,0
417,9
666,6
3,0
160,0
13,0
0,0
11,9
0,0
455,7
71,1
123,5
510,3
348,5
441,3
419,0
661,5
4,0
161,0
12,8
0,1
14,0
0,0
467,6
71,1
123,5
522,5
346,9
442,0
419,9
654,7
5,0
162,0
12,6
0,2
14,3
0,0
477,5
71,4
123,8
534,4
344,3
442,6
420,0
649,8
6,0
163,0
12,4
0,5
14,1
0,0
483,6
70,8
123,9
546,2
342,6
443,1
420,4
641,7
7,0
164,0
12,2
0,7
14,3
0,0
489,2
71,1
124,1
558,6
340,0
443,5
420,5
633,8
8,0
165,0
12,0
0,6
14,5
0,0
495,8
71,1
124,7
569,1
338,8
444,1
420,6
628,2
9,0
166,0
11,8
0,6
14,7
0,0
502,1
71,6
125,4
580,3
338,4
444,7
420,4
621,4
10,0
167,0
11,5
0,2
14,6
0,0
506,4
71,8
125,7
589,5
335,7
445,4
420,2
614,5
11,0
168,0
11,3
0,2
14,9
0,0
511,0
71,6
127,3
599,7
335,2
446,0
420,6
608,5
12,0
169,0
11,1
0,2
15,2
0,0
516,3
71,8
127,8
608,5
332,7
446,8
420,5
602,6
13,0
170,0
10,9
0,2
15,4
0,0
520,4
72,1
127,9
616,9
332,0
447,6
420,4
596,1
14,0
171,0
10,7
0,5
15,8
0,0
524,1
72,0
128,0
624,2
331,0
448,4
421,0
589,9
15,0
172,0
10,5
0,6
15,8
0,0
526,5
71,7
128,2
632,3
329,2
449,7
421,0
583,8
16,0
173,0
10,3
0,9
15,7
0,0
530,2
71,7
128,6
639,0
330,0
450,7
421,7
578,6
17,0
174,0
10,0
0,7
15,8
0,0
532,4
71,6
128,6
646,7
329,3
451,9
422,2
573,9
18,0
175,0
9,8
0,7
15,9
0,0
534,3
72,2
128,7
652,7
329,1
453,3
422,8
568,6
19,0
176,0
9,7
0,6
16,1
0,0
535,3
72,3
129,1
657,5
328,9
454,9
423,8
564,1
20,0
177,0
9,4
0,6
16,0
0,0
537,2
72,5
129,7
663,0
329,2
456,9
424,8
560,1
21,0
178,0
9,2
0,6
16,2
0,0
538,2
72,3
129,5
667,7
328,6
458,6
425,7
555,8
22,0
179,0
9,0
0,7
16,2
0,0
539,3
72,7
129,8
672,8
328,9
460,4
427,4
551,6
23,0
180,0
8,8
0,8
16,1
0,0
539,2
72,5
129,3
677,9
328,8
462,6
428,7
548,0
24,0
181,0
8,6
0,7
15,9
0,0
538,7
72,2
128,9
680,7
329,2
464,6
430,2
544,0
25,0
182,0
8,4
0,6
15,7
0,0
538,3
72,8
128,6
682,3
330,4
466,7
431,8
539,9
26,0
183,0
8,2
0,5
15,5
0,0
537,2
72,3
128,6
685,0
331,4
468,7
433,2
536,7
27,0
184,0
8,1
0,6
15,4
0,0
537,0
73,4
129,1
687,9
330,9
470,7
434,5
534,1
28,0
185,0
7,9
0,7
15,6
0,0
536,5
73,2
129,5
687,5
331,4
473,2
436,2
530,4
29,0
186,0
7,7
0,8
15,8
0,0
535,5
72,1
129,5
690,0
332,5
476,0
437,1
526,5
30,0
187,0
7,5
0,9
15,8
0,0
535,2
72,4
129,4
692,0
334,4
478,5
439,2
523,9
31,0
188,0
7,3
0,9
15,8
0,0
534,3
73,0
128,8
693,3
335,2
481,1
440,6
520,9
32,0
189,0
7,1
0,7
15,8
0,0
533,4
72,4
128,5
697,0
336,7
483,3
442,3
518,0
33,0
190,0
6,9
0,5
15,8
0,0
532,2
72,7
128,3
696,9
338,0
485,8
444,2
515,1
34,0
191,0
6,8
0,6
15,5
0,0
531,1
73,8
128,0
698,0
338,6
488,3
446,0
512,6
35,0
192,0
6,6
0,5
15,4
0,0
530,0
73,0
127,9
696,5
340,5
490,6
447,6
510,5
36,0
193,0
6,4
0,6
15,3
0,0
528,6
73,2
127,6
698,3
341,0
493,0
449,5
507,1
37,0
194,0
6,3
0,4
15,3
0,0
527,0
73,8
127,8
696,1
341,4
495,7
451,3
504,3
38,0
195,0
6,1
0,1
15,5
0,0
525,8
73,1
127,2
695,3
342,8
498,1
452,9
502,3
39,0
196,0
5,9
0,1
15,6
0,0
523,9
73,2
127,0
693,4
343,8
500,4
455,3
500,0
40,0
197,0
5,8
0,0
15,4
0,0
522,3
73,6
126,5
693,2
344,6
502,6
457,2
497,7
41,0
198,0
5,6
0,0
15,3
0,0
520,1
73,1
126,1
689,6
346,5
504,8
459,3
495,6
42,0
199,0
5,4
0,0
15,4
0,0
519,2
73,1
125,6
691,3
347,2
506,5
461,5
493,0
43,0
200,0
5,3
0,0
15,4
0,0
518,1
73,1
125,5
689,7
348,7
508,5
463,3
491,0
44,0
201,0
5,2
0,0
15,3
0,0
517,4
73,1
125,3
687,6
350,1
510,0
465,3
489,5
45,0
202,0
5,0
0,1
15,2
0,0
516,4
74,0
125,4
688,3
349,4
511,8
467,4
486,8
46,0
203,0
4,9
0,2
15,0
0,0
515,0
74,2
125,7
687,7
352,6
513,2
469,5
486,1
47,0
204,0
4,7
0,4
14,5
0,0
513,5
74,2
125,4
684,2
353,0
514,9
471,2
483,9
48,0
205,0
4,6
0,3
14,3
0,0
512,1
73,7
125,0
681,2
355,5
516,4
473,5
481,8
49,0
206,0
4,5
0,2
14,0
0,0
508,6
74,3
123,8
679,1
356,8
516,8
475,3
479,9
50,0
207,0
4,3
0,1
13,8
0,0
505,1
74,8
123,1
676,6
357,0
518,2
477,1
478,9
51,0
208,0
4,2
0,0
13,6
0,0
501,5
73,7
122,9
672,6
359,1
518,8
478,8
477,6
52,0
209,0
4,1
0,0
13,4
0,0
498,0
72,9
122,2
668,9
359,4
519,7
480,6
475,9
53,0
210,0
4,0
0,0
13,2
0,0
495,0
74,3
121,9
663,8
359,5
520,2
482,1
474,7
54,0
211,0
3,8
0,0
13,1
0,0
490,8
74,0
121,6
659,9
361,9
520,4
483,2
473,3
55,0
212,0
3,7
0,0
13,0
0,0
488,2
74,2
121,7
653,0
361,9
520,9
485,2
471,7
56,0
213,0
3,7
0,0
12,9
0,0
484,9
74,0
121,2
648,2
363,9
521,4
485,9
470,9
57,0
214,0
3,5
0,0
12,8
0,0
481,9
73,8
120,8
643,8
364,7
521,4
487,8
470,4
58,0
215,0
3,5
0,0
12,6
0,0
479,1
74,1
119,9
640,3
363,2
521,3
489,0
469,3
59,0
216,0
3,3
0,0
12,5
0,0
475,8
73,9
119,3
633,5
364,6
521,3
489,9
468,5
60,0
217,0
3,2
0,0
12,3
0,0
473,2
73,1
118,5
629,2
366,8
521,2
490,9
468,2
61,0
218,0
3,1
0,0
12,3
0,0
470,7
73,5
118,1
622,7
367,4
521,3
491,3
469,6
62,0
219,0
3,1
0,0
12,2
0,0
467,8
73,5
117,6
619,3
369,5
520,9
493,0
466,7
63,0
220,0
2,9
0,0
12,1
0,0
465,5
73,9
117,7
613,5
369,0
520,4
493,1
466,5
64,0
221,0
2,8
0,0
12,0
0,0
462,8
74,6
117,8
608,7
370,2
520,6
494,2
466,1
65,0
222,0
2,8
0,0
12,0
0,0
460,2
73,2
117,6
604,1
371,6
520,2
494,8
465,8
66,0
223,0
2,7
0,0
12,0
0,0
457,6
73,2
117,1
599,8
371,5
520,2
495,0
465,2
67,0
224,0
2,6
0,0
11,9
0,0
455,3
73,0
116,7
596,8
370,7
519,9
495,4
465,1
68,0
225,0
2,5
0,0
11,9
0,0
453,4
73,1
116,3
593,5
371,7
520,1
495,7
464,8
69,0
226,0
2,4
0,0
11,8
0,0
451,1
73,1
115,6
588,9
372,2
519,6
495,7
464,7
70,0
227,0
2,3
0,0
11,7
0,0
448,3
73,2
115,0
585,6
371,6
519,4
496,0
464,4
71,0
228,0
2,3
0,0
11,5
0,0
445,9
73,7
114,6
581,6
368,8
519,4
496,0
464,7
72,0
229,0
2,2
0,0
11,3
0,0
443,5
73,6
113,9
577,3
372,4
519,1
496,2
464,3
73,0
230,0
2,1
0,0
11,1
0,0
441,5
73,6
113,9
573,3
372,9
519,0
495,7
463,8
74,0
231,0
2,0
0,0
11,0
0,0
438,4
74,5
114,0
567,5
373,3
519,0
496,2
463,3
75,0
232,0
2,0
0,0
11,0
0,0
436,0
73,6
113,5
563,3
374,6
518,8
495,8
463,4
76,0
233,0
1,9
0,0
10,9
0,0
434,3
73,4
113,1
559,8
374,6
518,6
495,8
463,0
77,0
234,0
1,8
0,0
10,9
0,0
432,2
72,9
112,5
556,2
375,5
518,0
495,7
463,3
78,0
235,0
1,8
0,0
10,7
0,0
430,4
72,8
112,2
553,3
371,1
517,8
495,4
463,4
79,0
236,0
1,7
0,0
10,3
0,0
428,5
72,8
111,5
549,6
371,7
517,2
494,9
463,3
80,0
237,0
1,6
0,0
9,6
0,0
426,4
72,8
111,1
544,6
374,3
516,7
494,6
463,1
81,0
238,0
1,6
0,0
9,0
0,0
424,3
72,8
110,5
539,8
375,1
515,9
494,3
463,1
82,0
239,0
1,6
0,0
8,5
0,0
421,8
73,7
110,2
533,6
376,4
515,2
493,8
463,2
83,0
240,0
1,5
0,0
8,1
0,0
419,3
74,1
109,9
526,5
377,3
514,1
492,8
463,2
84,0
241,0
1,5
0,0
8,0
0,0
417,1
74,0
110,3
520,1
378,8
513,4
492,3
462,3
85,0
242,0
1,4
0,0
8,0
0,0
414,5
72,6
109,7
514,7
379,2
512,1
491,2
462,2
86,0
243,0
1,4
0,0
7,9
0,0
412,9
72,5
109,5
510,0
379,1
511,0
490,2
462,2
87,0
244,0
1,4
0,0
7,9
0,0
411,2
72,4
109,1
504,7
375,0
509,6
488,7
462,2
88,0
245,0
1,4
0,0
7,9
0,0
409,5
72,3
108,8
500,1
373,2
508,0
487,4
462,3
89,0
246,0
1,3
0,0
7,9
0,0
408,0
72,4
108,4
494,6
374,8
506,6
486,0
461,5
90,0
247,0
1,3
0,0
7,9
0,0
406,8
72,3
108,2
489,9
374,3
505,4
484,5
461,3
91,0
248,0
1,2
0,0
7,8
0,0
405,5
72,5
108,0
485,4
374,3
503,3
482,9
461,3
92,0
249,0
1,2
0,0
7,8
0,0
403,8
73,1
107,8
480,7
373,3
501,5
480,9
461,8
93,0
250,0
1,2
0,0
7,8
0,0
402,6
72,9
107,8
476,1
374,3
500,2
479,0
461,1
94,0
251,0
1,1
0,0
7,8
0,0
401,6
73,4
108,1
471,7
373,2
498,8
477,0
460,1
95,0
252,0
1,1
0,0
7,8
0,0
400,7
72,7
108,0
467,9
373,0
497,3
475,0
460,3
96,0
253,0
1,1
0,0
7,8
0,0
400,4
72,2
107,5
464,4
371,7
495,8
473,4
460,5
97,0
254,0
1,0
0,0
7,8
0,0
399,8
72,6
107,4
461,5
370,8
494,3
471,6
460,7
98,0
255,0
1,0
0,0
7,8
0,0
399,5
72,4
107,3
457,5
367,8
492,8
469,6
460,9
99,0
256,0
1,0
0,0
7,8
0,0
399,2
72,2
107,0
454,6
367,9
491,3
467,8
461,1
100,0
257,0
1,0
0,0
7,8
0,0
397,9
72,3
106,8
452,3
368,8
489,4
465,9
460,9
Particulates Calculations
Page 1 of 2
DATA 2018-01-22 EPA PI 20162 RUN 5 CAT 4 MODEL GM 60
101,0
258,0
0,9
0,0
8,0
0,0
396,2
72,0
106,5
449,7
367,0
487,2
464,3
461,3
102,0
259,0
0,9
0,0
8,0
0,0
394,8
72,8
106,2
446,8
365,7
486,0
462,3
461,0
103,0
260,0
0,9
0,0
8,3
0,0
393,5
73,1
106,2
444,0
366,1
484,0
460,2
461,7
104,0
261,0
0,8
0,0
8,3
0,0
391,4
73,2
106,2
440,8
366,3
482,8
458,8
462,0
105,0
262,0
0,8
0,0
8,3
0,0
389,7
72,1
106,3
439,0
365,1
481,0
456,9
462,7
106,0
263,0
0,8
0,0
8,3
0,0
389,1
72,5
106,2
437,0
363,2
479,8
455,6
463,1
107,0
264,0
0,7
0,0
8,3
0,0
388,6
72,5
105,9
435,5
363,7
478,3
454,2
464,8
108,0
265,0
0,7
0,0
8,3
0,0
387,9
72,4
105,5
433,5
361,4
476,9
452,8
465,6
109,0
266,0
0,6
0,0
8,3
0,0
386,6
72,7
105,7
431,1
362,2
475,8
451,4
466,7
110,0
267,0
0,7
0,0
7,7
0,0
383,8
72,2
105,1
429,3
358,5
474,9
450,2
468,2
111,0
268,0
0,6
0,0
7,4
0,0
382,2
72,2
104,8
428,1
355,9
473,0
449,0
470,5
112,0
269,0
0,6
0,0
7,5
0,0
380,7
72,7
104,5
427,0
355,7
471,7
447,9
473,3
113,0
270,0
0,5
0,0
7,4
0,0
379,5
72,8
104,6
425,8
358,2
470,0
446,3
476,3
114,0
271,0
0,5
0,0
7,5
0,0
378,8
73,2
104,6
423,5
354,9
468,9
445,8
479,8
115,0
272,0
0,4
0,0
7,5
0,0
378,6
72,3
104,6
422,1
355,7
467,7
444,3
484,0
116,0
273,0
0,4
0,0
7,5
0,0
378,1
72,3
104,6
420,9
353,5
466,7
443,6
487,4
117,0
274,0
0,4
0,0
7,5
0,0
378,0
72,1
104,4
419,3
353,3
465,2
442,7
491,7
118,0
275,0
0,4
0,0
7,4
0,0
377,0
72,0
104,1
417,5
349,9
463,6
442,0
495,4
119,0
276,0
0,3
0,0
7,4
0,0
377,1
72,1
104,1
416,6
346,2
462,3
441,2
499,9
120,0
277,0
0,3
0,0
7,4
0,0
377,3
72,0
104,0
415,4
344,4
461,0
440,6
503,0
121,0
278,0
0,2
0,0
7,4
0,0
376,8
72,0
103,6
414,1
342,8
459,2
440,0
507,4
122,0
279,0
0,2
0,0
7,3
0,0
376,4
72,0
103,7
412,0
340,0
458,0
439,4
510,4
123,0
280,0
0,2
0,0
6,3
0,0
375,2
72,6
103,7
410,6
338,7
456,4
438,1
514,2
124,0
281,0
0,2
0,0
6,1
0,0
374,1
72,9
103,8
408,7
337,0
455,2
437,8
516,2
125,0
282,0
0,1
0,0
6,1
0,0
374,2
72,3
103,8
406,7
336,6
453,6
436,7
518,6
126,0
283,0
0,1
0,0
6,2
0,0
373,8
73,1
103,9
405,0
334,5
452,2
436,1
520,3
127,0
284,0
0,1
0,0
6,2
0,0
374,1
71,8
103,6
403,8
333,0
450,9
435,3
520,9
128,0
285,0
0,1
0,0
6,2
0,0
374,3
72,7
103,4
401,9
330,4
448,9
434,6
522,4
129,0
286,0
0,1
0,0
6,2
0,0
374,3
72,0
103,4
400,2
328,0
447,6
433,5
524,0
130,0
287,0
0,0
0,0
6,2
0,0
374,8
72,2
103,1
398,6
326,6
446,3
432,7
525,3
Particulates Calculations
Page 2 of 2
DATA 2018-01-22 EPA PI 20162 RUN 5 CAT 4 MODEL GM 60
Manufacturer: HEARTHSTONE
Model:
GM 60
Overall Heating Efficiency:
75,37%
30,17
Run:
5
Combustion Efficiency:
98,56%
342,07
Project #:
PI 20162
Heat Transfer Efficiency:
76,47%
9,81
Test Duration: 130
min
HHV
LHV
Heat Output:
33 576 Btu/h
35 395 kJ/h
Eff
75,37%
81,46%
Heat Input:
44 548 Btu/h
46 962 kJ/h
Comb Eff
98,56%
98,56%
Ultimate CO2
HT Eff
76,47%
82,65%
CO2-ult
19,64
Burn Duration:
2,17
h
Output
35 395
kJ/h
F0
Burn Rate
2,37
kg/h
1,063
Burn Rate:
5,22
lb/h
2,371
kg/h
Grams CO
111
g
Input
46 962
kJ/h
Stack Temp:
455,7
Deg. F
235,4
Deg. C
MC wet
16,69
Air Fuel Ratio (A/F)
Dry Molecular Weight (Md)
Dry Moles Exhaust Gas (Nr):
Air Fuel Ratio (A/F)
Note: In the “Input data”, "Calc. % O2", "Fuel Properties", and
“Mass Balance” columns, [e], [d], [g], [a]. [b], [c], [h], [u], [w],
[j], and [k] refer to their respective variables in Clauses 13.7.3
CSA B415.1 OE Calculations
Page 1 of 1
St-jean-sur-Richelieu, February 6th 2018
Client: Hearthstone
Project: PI-20162
Model: GM-60
Page 16 of 28
M_rap_EPAwoodstove V1 – 2015 july 30th
APPENDIX 2: Proportionality results
DATA 2018-01-15 EPA PI 20162 RUN1 CAT1 MODEL GM 60
Average
Average
Average
Average
15,47
Inlet +
Inlet +
0,245
Outlet
Outlet
Average
Average
#1
#2
Tunnel
Temp.
Temp.
100,48
100,96
System 1
System 2
SQRT
Velocity
Meter 1
Meter 2
Vol.Std.
Vol.Std.
Delta-P
PR1
PR2
Time
Ft/Sec
Deg. R
Deg. R
%%
(ft3)
(ft3)
min
(in H2O)2
15,802
534,4
534,3
0,166
0,174
0
0,23928
15,519
534,2
534,3
100,13
104,00
0,166
0,174
1
0,2413909
15,581
534,0
534,3
99,34
102,54
0,166
0,174
2
0,2428571
15,336
534,0
534,3
105,20
104,63
0,170
0,173
3
0,2388564
15,479
533,9
534,4
105,96
103,45
0,174
0,173
4
0,2407595
15,512
533,9
534,3
103,44
101,86
0,175
0,173
5
0,2432747
15,456
533,8
534,3
101,33
102,25
0,173
0,174
6
0,243274
15,488
533,8
534,3
100,99
101,74
0,172
0,175
7
0,2438998
15,509
533,7
534,3
101,81
101,51
0,172
0,174
8
0,2438994
15,583
533,8
534,3
100,86
100,90
0,173
0,174
9
0,2453508
15,499
533,8
534,4
100,91
101,26
0,172
0,174
10
0,2443143
15,425
533,7
534,3
102,20
101,45
0,173
0,174
11
0,2432739
15,555
533,7
534,3
99,73
101,26
0,172
0,174
12
0,245351
15,465
533,6
534,3
100,66
101,42
0,171
0,174
13
0,2438992
15,524
533,6
534,3
100,52
101,91
0,171
0,174
14
0,244315
15,574
533,7
534,3
100,62
101,07
0,171
0,174
15
0,2449365
15,523
533,8
534,4
102,61
100,99
0,173
0,173
16
0,244307
15,557
533,8
534,4
102,35
100,61
0,175
0,173
17
0,2449371
15,481
533,8
534,4
102,65
101,01
0,175
0,173
18
0,2438996
15,634
533,7
534,4
99,32
100,87
0,173
0,174
19
0,2463829
15,526
533,7
534,4
99,98
101,77
0,170
0,175
20
0,2443144
15,554
533,8
534,4
102,53
101,22
0,172
0,174
21
0,244413
15,530
533,8
534,4
100,17
101,92
0,172
0,174
22
0,2443159
15,590
533,9
534,5
100,74
101,11
0,171
0,174
23
0,2453517
15,583
533,8
534,5
99,67
100,98
0,171
0,174
24
0,2453512
15,198
533,8
534,5
102,20
103,77
0,170
0,174
25
0,2392686
15,578
533,8
534,4
101,22
101,10
0,171
0,174
26
0,2449368
15,566
533,8
534,4
102,80
101,13
0,173
0,173
27
0,244323
15,614
533,9
534,5
99,49
101,51
0,172
0,174
28
0,245351
15,609
533,9
534,5
101,83
100,84
0,172
0,174
29
0,2453508
15,530
533,9
534,5
100,38
101,64
0,172
0,174
30
0,2443148
15,579
533,9
534,5
99,76
101,39
0,171
0,175
31
0,245351
15,485
533,9
534,6
102,45
101,35
0,172
0,174
32
0,2438989
15,374
534,0
534,6
101,03
102,71
0,172
0,174
33
0,2418102
15,618
534,1
534,7
99,64
101,09
0,170
0,174
34
0,2457639
15,549
534,2
534,7
100,08
101,20
0,171
0,174
35
0,2449366
15,481
534,2
534,8
101,14
101,54
0,171
0,174
36
0,2438986
15,561
534,2
534,8
101,28
100,59
0,173
0,174
37
0,2453511
15,465
534,2
534,8
99,75
101,76
0,171
0,174
38
0,2438998
15,430
534,2
534,8
102,69
101,51
0,172
0,174
39
0,2428576
15,583
534,2
534,8
99,75
101,65
0,172
0,174
40
0,2449365
15,559
534,3
534,9
101,83
100,83
0,172
0,174
41
0,2449365
15,553
534,3
534,9
100,80
101,20
0,173
0,174
42
0,2449365
15,571
534,3
534,9
101,79
100,82
0,173
0,174
43
0,2453514
15,537
534,3
534,9
101,66
100,93
0,174
0,174
44
0,2449369
15,597
534,3
534,9
99,96
100,71
0,172
0,174
45
0,2457637
15,469
534,3
534,9
100,51
102,77
0,171
0,175
46
0,2432749
15,618
534,4
534,9
101,51
100,50
0,172
0,174
47
0,2457638
15,515
534,4
535,0
100,27
101,35
0,172
0,174
48
0,2443144
15,507
534,5
535,0
102,12
101,21
0,172
0,174
49
0,2443155
15,407
534,4
535,0
100,03
102,14
0,172
0,174
50
0,242858
15,426
534,4
534,9
100,15
101,84
0,170
0,174
51
0,2432748
15,329
534,3
534,9
102,93
102,37
0,172
0,174
52
0,2414634
15,530
534,4
535,0
99,57
101,72
0,171
0,174
53
0,2443145
Proportional Rates
Particulates Calculations
Page 1 of 6
DATA 2018-01-15 EPA PI 20162 RUN1 CAT1 MODEL GM 60
15,546
534,4
535,0
99,29
101,44
0,169
0,175
54
0,2449374
15,566
534,5
535,0
101,32
100,23
0,171
0,174
55
0,2453512
15,500
534,5
535,1
99,51
101,28
0,171
0,173
56
0,2443151
15,577
534,5
535,1
101,59
100,38
0,172
0,174
57
0,2457636
15,466
534,4
535,0
99,83
101,91
0,172
0,174
58
0,2439
15,523
534,4
535,0
101,73
101,61
0,171
0,175
59
0,2443149
15,597
534,4
535,0
101,24
101,15
0,173
0,174
60
0,2453513
15,448
534,5
535,1
100,20
102,03
0,171
0,174
61
0,2432747
15,572
534,5
535,1
101,29
100,92
0,171
0,174
62
0,2453517
15,536
534,5
535,1
99,23
101,31
0,171
0,174
63
0,2449362
15,557
534,4
535,0
101,47
100,66
0,172
0,174
64
0,245352
15,488
534,4
535,0
99,84
101,94
0,172
0,174
65
0,2438998
15,513
534,4
535,0
102,13
101,44
0,171
0,174
66
0,2439002
15,579
534,5
535,0
101,43
100,87
0,173
0,174
67
0,2453518
15,595
534,5
535,1
99,78
100,54
0,172
0,174
68
0,2457602
15,535
534,5
535,1
101,28
100,83
0,172
0,174
69
0,2449379
15,420
534,5
535,1
101,79
101,72
0,173
0,174
70
0,2432749
15,420
534,5
535,0
102,35
101,44
0,173
0,174
71
0,2432751
15,456
534,4
535,0
102,38
101,52
0,174
0,174
72
0,2432756
15,457
534,4
535,1
102,38
101,54
0,173
0,173
73
0,2432767
15,652
534,5
535,1
98,86
100,58
0,171
0,174
74
0,2463721
15,554
534,5
535,1
101,80
101,06
0,172
0,174
75
0,2449372
15,500
534,5
535,1
99,59
101,41
0,172
0,174
76
0,2443153
15,339
534,5
535,1
100,41
102,47
0,169
0,174
77
0,2418113
15,416
534,4
535,1
102,52
101,75
0,171
0,174
78
0,2428583
15,511
534,5
535,1
102,36
101,71
0,174
0,174
79
0,2438995
15,640
534,6
535,1
100,95
100,21
0,173
0,174
80
0,2463833
15,318
534,6
535,2
102,53
102,72
0,173
0,174
81
0,2413926
15,474
534,6
535,2
101,62
101,33
0,173
0,174
82
0,2439992
15,527
534,6
535,2
101,00
101,57
0,173
0,175
83
0,2449375
15,415
534,5
535,1
100,04
101,45
0,171
0,174
84
0,2432757
15,415
534,5
535,1
100,34
101,82
0,170
0,174
85
0,242858
15,555
534,5
535,1
99,34
100,94
0,170
0,174
86
0,2449378
15,498
534,6
535,2
99,72
101,61
0,170
0,174
87
0,2443154
15,533
534,6
535,2
99,46
101,27
0,170
0,175
88
0,2449373
15,522
534,6
535,2
99,84
101,41
0,170
0,175
89
0,2449373
15,475
534,5
535,2
99,23
101,14
0,170
0,174
90
0,2443157
15,405
534,5
535,1
101,53
101,90
0,171
0,174
91
0,2432753
15,191
534,5
535,1
101,61
103,29
0,171
0,174
92
0,239315
15,276
534,6
535,1
101,26
102,59
0,170
0,174
93
0,2407597
15,423
534,6
535,2
100,43
101,15
0,170
0,173
94
0,2432751
15,400
534,7
535,2
100,06
101,37
0,170
0,173
95
0,2428578
15,539
534,6
535,2
99,70
100,04
0,170
0,173
96
0,2453515
15,404
534,6
535,2
102,07
101,23
0,172
0,173
97
0,2432749
15,451
534,6
535,2
99,87
101,16
0,172
0,174
98
0,2438999
15,355
534,6
535,2
100,34
102,45
0,170
0,174
99
0,2418101
15,582
534,6
535,2
101,09
100,36
0,171
0,174
100
0,2457646
15,524
534,7
535,3
99,62
100,42
0,172
0,173
101
0,2449374
15,605
534,7
535,3
101,15
100,16
0,172
0,174
102
0,2463834
15,508
534,6
535,2
100,06
101,25
0,173
0,174
103
0,2449379
15,554
534,6
535,2
101,26
100,56
0,173
0,175
104
0,2457648
15,300
534,6
535,2
101,15
101,73
0,172
0,174
105
0,2414186
15,515
534,6
535,2
100,18
100,75
0,170
0,173
106
0,2443161
15,583
534,6
535,2
101,09
100,52
0,172
0,173
107
0,245765
15,544
534,7
535,2
100,66
101,51
0,173
0,174
108
0,2449376
15,488
534,7
535,2
101,86
101,39
0,173
0,175
109
0,2443155
15,390
534,7
535,2
101,56
102,14
0,173
0,175
110
0,2428583
15,381
534,6
535,2
102,16
101,55
0,173
0,174
111
0,2428583
15,428
534,6
535,2
101,99
101,96
0,173
0,174
112
0,243275
15,577
534,6
535,2
101,28
101,39
0,173
0,175
113
0,2453517
15,525
534,7
535,3
99,51
100,37
0,172
0,174
114
0,2449374
Particulates Calculations
Page 2 of 6
DATA 2018-01-15 EPA PI 20162 RUN1 CAT1 MODEL GM 60
15,474
534,7
535,3
101,78
101,34
0,172
0,174
115
0,2441628
15,513
534,8
535,4
99,68
100,26
0,172
0,174
116
0,2449376
15,559
534,8
535,3
99,94
100,12
0,171
0,173
117
0,2457646
15,524
534,7
535,3
101,14
100,63
0,173
0,174
118
0,2453521
15,424
534,7
535,3
100,40
100,98
0,172
0,174
119
0,2432742
15,620
534,8
535,3
100,13
100,54
0,171
0,174
120
0,2463833
15,671
534,8
535,4
99,62
100,08
0,172
0,174
121
0,2474104
15,598
534,8
535,4
98,62
100,14
0,171
0,174
122
0,246384
15,465
534,8
535,4
99,73
100,90
0,170
0,174
123
0,2443157
15,452
534,8
535,3
99,82
101,08
0,170
0,174
124
0,2443153
15,450
534,7
535,3
98,98
100,98
0,170
0,174
125
0,244315
15,395
534,7
535,3
102,33
101,99
0,171
0,174
126
0,2428579
15,537
534,8
535,4
99,28
100,20
0,172
0,174
127
0,245352
15,508
534,8
535,4
101,26
100,73
0,172
0,174
128
0,2449378
15,502
534,8
535,4
99,21
100,58
0,172
0,174
129
0,2449405
15,584
534,8
535,4
98,68
100,28
0,170
0,174
130
0,2463839
15,359
534,8
535,4
102,43
101,60
0,172
0,174
131
0,242882
15,540
534,8
535,4
98,49
100,20
0,172
0,174
132
0,2457648
15,549
534,8
535,4
99,20
100,13
0,170
0,173
133
0,2453518
15,467
534,8
535,4
101,26
101,42
0,171
0,174
134
0,2443153
15,501
534,9
535,5
101,41
100,91
0,173
0,174
135
0,2449382
15,554
534,9
535,4
100,72
101,21
0,173
0,175
136
0,245765
15,578
534,9
535,4
98,30
99,83
0,171
0,174
137
0,2463841
15,415
534,8
535,4
99,53
100,48
0,170
0,173
138
0,2439006
15,414
534,8
535,4
101,14
101,67
0,171
0,174
139
0,2438995
15,449
534,8
535,4
99,92
100,97
0,171
0,174
140
0,2439007
15,531
534,8
535,4
98,69
100,24
0,170
0,173
141
0,2453519
15,521
534,8
535,4
100,34
100,19
0,171
0,173
142
0,2453517
15,359
534,9
535,4
101,44
101,70
0,172
0,174
143
0,2428585
15,532
534,8
535,4
100,02
100,63
0,172
0,174
144
0,2457642
15,525
534,8
535,4
98,87
99,73
0,171
0,174
145
0,2457645
15,627
534,8
535,4
97,63
99,07
0,170
0,173
146
0,2474105
15,508
534,7
535,3
101,44
100,88
0,171
0,174
147
0,2449377
15,556
534,8
535,4
99,84
100,31
0,172
0,174
148
0,2457639
15,542
534,8
535,4
100,60
100,48
0,172
0,174
149
0,2457645
15,512
534,8
535,4
100,81
100,52
0,173
0,174
150
0,2453522
15,529
534,8
535,4
98,35
99,97
0,171
0,174
151
0,2457646
15,367
534,8
535,4
99,65
101,16
0,169
0,174
152
0,243275
15,402
534,7
535,4
99,49
100,88
0,170
0,174
153
0,2439004
15,504
534,7
535,3
99,21
100,19
0,170
0,173
154
0,2449379
15,558
534,7
535,4
101,04
100,63
0,172
0,174
155
0,2457647
15,541
534,8
535,4
99,07
100,43
0,172
0,174
156
0,2457647
15,422
534,8
535,4
101,58
101,33
0,172
0,174
157
0,2439004
15,278
534,7
535,3
102,13
102,13
0,173
0,174
158
0,2418107
15,519
534,7
535,3
100,38
100,43
0,173
0,174
159
0,2457643
15,554
534,7
535,3
98,67
99,74
0,172
0,174
160
0,246383
15,459
534,6
535,3
100,44
101,22
0,171
0,174
161
0,2443155
15,520
534,7
535,3
99,07
100,07
0,171
0,174
162
0,2453518
15,535
534,7
535,3
100,24
100,20
0,171
0,173
163
0,2457066
15,419
534,7
535,3
101,38
101,25
0,173
0,174
164
0,2439002
15,469
534,7
535,3
100,60
100,76
0,173
0,174
165
0,2449372
15,493
534,7
535,3
98,83
100,35
0,171
0,174
166
0,2453521
15,551
534,7
535,3
98,17
99,28
0,170
0,173
167
0,2463835
15,389
534,7
535,3
99,83
101,32
0,170
0,173
168
0,2432747
15,439
534,7
535,3
101,80
101,41
0,172
0,174
169
0,2438998
15,509
534,7
535,3
99,33
100,04
0,172
0,174
170
0,2453536
15,489
534,7
535,3
100,22
100,36
0,171
0,173
171
0,2449379
15,342
534,8
535,3
99,86
101,12
0,171
0,173
172
0,2428585
15,432
534,7
535,3
99,31
100,69
0,170
0,174
173
0,2443159
15,553
534,7
535,3
98,33
99,58
0,170
0,174
174
0,2463837
15,351
534,6
535,2
100,50
101,32
0,170
0,174
175
0,2428583
Particulates Calculations
Page 3 of 6
DATA 2018-01-15 EPA PI 20162 RUN1 CAT1 MODEL GM 60
15,469
534,6
535,2
101,53
101,46
0,172
0,174
176
0,2443158
15,443
534,7
535,3
101,87
101,67
0,174
0,175
177
0,2443155
15,287
534,7
535,3
100,36
101,86
0,172
0,175
178
0,241811
15,469
534,7
535,3
99,00
100,39
0,170
0,174
179
0,244937
15,428
534,6
535,2
101,31
101,18
0,172
0,174
180
0,2443148
15,464
534,6
535,2
99,16
100,11
0,172
0,174
181
0,245084
15,497
534,6
535,2
98,90
100,52
0,170
0,174
182
0,2453523
15,373
534,5
535,2
101,00
101,70
0,171
0,174
183
0,2428581
15,479
534,6
535,2
101,27
100,93
0,172
0,174
184
0,2449374
15,531
534,6
535,2
99,15
100,05
0,172
0,174
185
0,2457644
15,245
534,7
535,2
100,36
101,62
0,170
0,173
186
0,2413928
15,417
534,6
535,2
99,03
100,20
0,170
0,173
187
0,2443157
15,481
534,6
535,1
98,79
100,19
0,170
0,173
188
0,2453521
15,466
534,6
535,1
98,75
100,21
0,170
0,174
189
0,244937
15,434
534,6
535,1
101,46
101,40
0,171
0,174
190
0,2439002
15,441
534,6
535,1
100,69
100,95
0,173
0,174
191
0,2443153
15,341
534,6
535,2
101,94
101,66
0,173
0,174
192
0,2428583
15,569
534,6
535,1
100,41
100,30
0,173
0,174
193
0,2463835
15,552
534,6
535,1
98,81
99,95
0,172
0,174
194
0,2463841
15,682
534,5
535,1
99,90
99,67
0,172
0,175
195
0,2484337
15,366
534,5
535,1
101,82
101,49
0,174
0,175
196
0,2432755
15,376
534,5
535,0
102,35
101,98
0,174
0,175
197
0,2429634
15,476
534,5
535,1
98,91
100,31
0,172
0,174
198
0,2449375
15,432
534,6
535,1
101,43
101,57
0,172
0,174
199
0,2443163
15,519
534,6
535,1
100,44
100,29
0,173
0,175
200
0,2457651
15,481
534,6
535,1
100,98
100,69
0,173
0,174
201
0,2453519
15,448
534,5
535,1
99,45
100,28
0,172
0,174
202
0,2449375
15,404
534,5
535,1
101,31
101,06
0,172
0,174
203
0,2443163
15,445
534,5
535,0
99,36
100,76
0,172
0,174
204
0,2443163
15,567
534,5
535,1
100,65
100,72
0,172
0,174
205
0,2463526
15,407
534,6
535,1
100,46
101,30
0,173
0,175
206
0,2439005
15,465
534,6
535,1
99,65
100,82
0,171
0,175
207
0,2449375
15,392
534,6
535,1
99,38
100,42
0,170
0,174
208
0,2439011
15,420
534,6
535,1
99,33
100,38
0,170
0,173
209
0,2443158
15,608
534,5
535,1
100,19
100,06
0,172
0,174
210
0,2474056
15,476
534,5
535,1
99,01
100,04
0,172
0,174
211
0,2449378
15,458
534,5
535,1
101,22
101,01
0,171
0,174
212
0,2443161
15,363
534,6
535,1
101,85
101,52
0,173
0,174
213
0,2432758
15,524
534,6
535,1
100,39
100,22
0,173
0,174
214
0,2457647
15,419
534,6
535,1
99,14
100,64
0,171
0,174
215
0,2443159
15,612
534,5
535,1
98,45
99,72
0,170
0,174
216
0,2474107
15,499
534,5
535,0
98,64
99,88
0,170
0,174
217
0,2457644
15,268
534,4
535,0
100,76
102,06
0,170
0,174
218
0,2418118
15,437
534,4
534,9
101,83
101,24
0,172
0,174
219
0,2440361
15,621
534,5
535,0
98,09
99,51
0,172
0,174
220
0,2474112
15,431
534,5
535,0
101,09
101,36
0,171
0,174
221
0,2443444
15,490
534,5
535,0
99,03
100,27
0,172
0,174
222
0,245352
15,505
534,5
535,0
100,74
100,35
0,172
0,174
223
0,2457651
15,499
534,4
535,0
100,55
100,06
0,173
0,174
224
0,2457654
15,459
534,4
535,0
100,59
101,07
0,173
0,175
225
0,2449378
15,386
534,4
534,9
99,75
101,26
0,171
0,174
226
0,2432761
15,627
534,4
534,9
100,52
99,92
0,172
0,174
227
0,2474105
15,518
534,5
535,0
101,23
100,36
0,174
0,174
228
0,2457652
15,358
534,5
535,0
101,49
101,24
0,174
0,174
229
0,2432752
15,410
534,5
535,0
101,49
100,85
0,173
0,174
230
0,2443155
15,499
534,4
535,0
99,01
100,29
0,172
0,174
231
0,2457645
15,446
534,4
534,9
101,29
100,58
0,172
0,174
232
0,2449379
15,418
534,4
534,9
99,47
100,76
0,172
0,174
233
0,2440864
15,541
534,4
534,9
98,56
100,37
0,170
0,174
234
0,2457649
15,513
534,4
534,9
98,75
100,10
0,170
0,174
235
0,2457646
15,557
534,4
534,9
98,58
100,13
0,170
0,174
236
0,2463838
Particulates Calculations
Page 4 of 6
DATA 2018-01-15 EPA PI 20162 RUN1 CAT1 MODEL GM 60
15,454
534,4
534,9
99,70
100,81
0,171
0,174
237
0,2449376
15,448
534,4
534,9
99,60
100,06
0,171
0,174
238
0,2449377
15,468
534,4
534,9
98,86
99,89
0,171
0,173
239
0,2453521
15,418
534,3
534,9
101,64
101,09
0,172
0,174
240
0,2443159
15,484
534,3
534,9
101,74
100,76
0,174
0,174
241
0,2449373
15,557
534,4
534,9
100,20
99,63
0,174
0,174
242
0,2463836
15,463
534,4
535,0
99,04
100,66
0,171
0,174
243
0,2449375
15,507
534,4
534,9
98,54
100,11
0,170
0,174
244
0,2457648
15,383
534,4
534,9
99,93
101,28
0,170
0,174
245
0,2438997
15,472
534,3
534,9
100,72
100,26
0,172
0,174
246
0,2453511
15,469
534,3
534,9
98,60
100,17
0,172
0,174
247
0,2453514
15,410
534,3
534,9
99,44
101,15
0,170
0,174
248
0,2439
15,517
534,3
534,9
98,97
100,48
0,170
0,174
249
0,2457645
15,512
534,4
534,9
100,69
100,05
0,172
0,174
250
0,2457645
15,418
534,4
534,9
99,49
101,11
0,172
0,174
251
0,2443155
15,382
534,3
534,9
101,57
101,00
0,172
0,174
252
0,2438998
15,493
534,3
534,8
100,51
100,29
0,174
0,174
253
0,2457642
15,533
534,2
534,8
100,28
100,19
0,173
0,175
254
0,2463852
15,521
534,2
534,8
98,92
100,14
0,172
0,174
255
0,2457643
15,512
534,2
534,8
101,23
100,58
0,172
0,174
256
0,2453517
15,490
534,3
534,8
98,83
100,64
0,172
0,174
257
0,245352
15,269
534,3
534,8
100,94
102,66
0,170
0,175
258
0,2418104
15,414
534,3
534,8
99,64
100,97
0,171
0,175
259
0,2443149
15,536
534,2
534,8
100,48
100,12
0,172
0,175
260
0,2463828
15,379
534,1
534,7
100,19
101,41
0,173
0,175
261
0,2439003
15,337
534,1
534,7
102,54
101,72
0,173
0,175
262
0,2428577
15,488
534,1
534,7
101,41
101,04
0,174
0,175
263
0,2449373
15,463
534,2
534,7
98,73
100,78
0,172
0,175
264
0,2449369
15,466
534,2
534,7
100,81
100,83
0,171
0,174
265
0,2449374
15,456
534,2
534,7
100,93
100,23
0,173
0,174
266
0,2449373
15,322
534,1
534,7
100,21
101,90
0,172
0,174
267
0,2428579
15,496
534,1
534,7
100,26
100,36
0,172
0,175
268
0,2457643
15,357
534,1
534,7
102,08
101,35
0,173
0,174
269
0,2432752
15,510
534,1
534,6
99,30
100,90
0,172
0,175
270
0,2453512
15,645
534,1
534,6
100,06
99,58
0,172
0,175
271
0,2478206
15,144
534,1
534,6
103,37
102,90
0,174
0,174
272
0,2399154
15,504
534,1
534,7
100,38
99,73
0,173
0,174
273
0,2457646
15,540
534,1
534,6
100,89
100,18
0,174
0,174
274
0,2463829
15,469
534,1
534,6
100,78
100,62
0,174
0,175
275
0,2453507
15,408
534,0
534,6
100,62
100,59
0,173
0,174
276
0,244315
15,280
534,0
534,6
102,67
102,29
0,173
0,174
277
0,2418104
15,559
534,1
534,6
98,57
100,60
0,172
0,175
278
0,246383
15,396
534,1
534,6
101,66
100,61
0,172
0,174
279
0,2438995
15,460
534,1
534,6
101,73
100,58
0,174
0,174
280
0,2449375
15,250
534,1
534,6
100,07
102,01
0,172
0,174
281
0,2418105
15,342
534,0
534,6
100,26
101,68
0,170
0,175
282
0,2432747
15,375
534,0
534,5
99,03
101,04
0,170
0,175
283
0,2438996
15,420
534,0
534,5
101,24
100,43
0,171
0,174
284
0,2441318
15,507
533,9
534,5
100,60
100,75
0,173
0,174
285
0,2453506
15,395
534,0
534,5
101,77
101,25
0,173
0,175
286
0,2438992
15,423
534,0
534,5
101,44
100,57
0,174
0,174
287
0,2443145
15,543
534,0
534,5
100,53
99,70
0,174
0,174
288
0,2463826
15,448
533,9
534,5
98,93
100,89
0,172
0,174
289
0,2449365
15,463
533,9
534,4
99,05
100,05
0,170
0,174
290
0,2453512
15,338
533,9
534,4
102,00
100,89
0,172
0,173
291
0,2428574
15,531
533,9
534,4
99,10
100,57
0,172
0,174
292
0,2457637
15,396
533,9
534,5
102,04
100,94
0,172
0,174
293
0,2438995
15,421
533,9
534,5
101,29
100,36
0,174
0,174
294
0,244315
15,503
533,9
534,4
101,16
100,52
0,174
0,174
295
0,2457638
15,443
533,9
534,5
98,72
100,72
0,172
0,175
296
0,2449366
15,403
533,9
534,4
99,20
101,23
0,170
0,175
297
0,2443134
Particulates Calculations
Page 5 of 6
DATA 2018-01-15 EPA PI 20162 RUN1 CAT1 MODEL GM 60
15,272
533,8
534,4
101,70
102,26
0,171
0,175
298
0,2418104
15,660
533,8
534,4
100,05
99,53
0,173
0,174
299
0,24782
15,514
533,9
534,4
101,15
100,18
0,174
0,174
300
0,2457634
15,393
533,9
534,4
99,96
101,40
0,172
0,174
301
0,2438891
15,416
533,9
534,4
99,58
101,21
0,171
0,175
302
0,2443145
15,602
533,8
534,4
98,13
99,97
0,170
0,175
303
0,2474097
15,465
533,8
534,3
99,01
100,34
0,170
0,175
304
0,2453508
15,425
533,8
534,3
101,73
100,73
0,172
0,174
305
0,2443146
15,481
533,8
534,3
99,61
101,15
0,172
0,174
306
0,2449367
15,617
533,9
534,3
100,36
99,64
0,172
0,175
307
0,2474097
15,355
533,8
534,3
101,56
101,60
0,174
0,175
308
0,2432736
15,322
533,8
534,3
101,98
100,98
0,173
0,174
309
0,2428573
15,535
533,8
534,3
98,74
100,61
0,172
0,174
310
0,2463829
15,466
533,7
534,3
101,17
100,05
0,172
0,175
311
0,2453507
15,422
533,7
534,2
99,74
101,16
0,172
0,174
312
0,2443139
15,382
533,7
534,2
100,27
101,72
0,171
0,175
313
0,2432736
15,643
533,7
534,3
97,90
100,01
0,170
0,175
314
0,2478193
15,617
533,7
534,2
99,82
99,88
0,172
0,175
315
0,2474088
15,545
533,7
534,3
99,29
100,01
0,172
0,174
316
0,2463826
15,249
533,7
534,3
102,34
102,15
0,173
0,175
317
0,2418105
15,492
533,7
534,2
101,25
99,87
0,174
0,174
318
0,2457634
15,422
533,7
534,2
99,33
101,65
0,172
0,175
319
0,2443144
15,442
533,7
534,2
99,35
101,62
0,170
0,175
320
0,2443142
15,510
533,7
534,2
99,11
100,49
0,170
0,175
321
0,2457624
15,327
533,8
534,3
100,41
101,63
0,171
0,175
322
0,2428569
15,452
533,8
534,3
99,97
100,98
0,171
0,175
323
0,2449362
15,537
533,8
534,3
98,46
100,20
0,171
0,175
324
0,2463823
15,310
533,7
534,2
102,26
101,41
0,172
0,174
325
0,2428562
15,474
533,7
534,2
98,95
100,87
0,172
0,175
326
0,2453506
15,412
533,6
534,2
99,95
101,43
0,170
0,175
327
0,2438989
15,458
533,7
534,2
101,40
100,69
0,172
0,175
328
0,2449359
15,350
533,7
534,2
102,20
101,07
0,174
0,174
329
0,2432736
15,478
533,7
534,2
98,86
100,96
0,172
0,175
330
0,2453505
15,445
533,7
534,2
101,12
100,47
0,172
0,175
331
0,2449361
15,591
533,6
534,1
99,56
99,41
0,173
0,174
332
0,2474094
15,404
533,6
534,1
99,48
101,14
0,172
0,175
333
0,2443141
15,260
533,6
534,1
101,85
102,18
0,171
0,175
334
0,2415323
15,398
533,6
534,1
101,40
101,12
0,173
0,174
335
0,2438989
15,323
533,6
534,1
102,05
101,32
0,173
0,174
336
0,2428569
15,413
533,7
534,1
101,58
100,84
0,174
0,174
337
0,2443146
15,339
533,7
534,1
102,15
101,13
0,174
0,174
338
0,2432734
15,400
533,6
534,1
99,70
101,14
0,173
0,175
339
0,244314
15,250
533,6
534,1
102,54
101,45
0,172
0,174
340
0,2418093
15,433
533,5
534,0
101,18
101,01
0,173
0,174
341
0,2443139
15,488
533,5
534,0
101,47
100,42
0,174
0,174
342
0,245351
15,321
533,6
534,1
99,64
102,22
0,172
0,175
343
0,2428571
15,452
533,6
534,1
100,36
100,69
0,171
0,175
344
0,2449362
15,535
533,6
534,1
98,37
100,16
0,171
0,175
345
0,2463832
15,439
533,6
534,0
100,97
100,33
0,172
0,174
346
0,2449363
15,445
533,5
534,0
101,44
100,37
0,174
0,174
347
0,2449366
15,433
533,5
534,0
101,74
100,98
0,174
0,174
348
0,2443141
15,684
533,5
534,0
99,99
98,97
0,174
0,174
349
0,2484316
15,324
533,6
534,0
102,05
101,46
0,174
0,174
350
0,2428563
15,388
533,6
534,0
101,89
100,69
0,174
0,174
351
0,2438983
15,598
533,5
534,0
98,40
99,76
0,172
0,174
352
0,2474084
15,457
533,5
534,0
99,17
100,64
0,171
0,175
353
0,2453502
15,428
533,4
534,0
100,12
100,62
0,171
0,175
354
0,2446668
Particulates Calculations
Page 6 of 6
DATA 2018-01-16 EPA PI 20162 RUN 2 CAT 2 MODEL GM 60
Average
Average
Average
Average
15,63
Inlet +
Inlet +
0,243
Outlet
Outlet
Average
Average
#1
#2
Tunnel
Temp.
Temp.
100,85
100,83
System 1
System 2
SQRT
Velocity
Meter 1
Meter 2
Vol.Std.
Vol.Std.
Delta-P
PR1
PR2
Time
Ft/Sec
Deg. R
Deg. R
%%
(ft3)
(ft3)
min
(in H2O)2
15,920
535,5
535,9
0,165
0,190
0
0,2392788
15,876
535,4
535,9
96,26
101,58
0,165
0,183
1
0,2443135
15,649
535,4
536,0
97,71
102,81
0,165
0,176
2
0,2407643
15,654
535,4
535,9
102,64
103,26
0,169
0,176
3
0,2403373
15,757
535,3
535,9
104,66
102,74
0,174
0,176
4
0,24139
15,631
535,3
535,9
104,09
101,89
0,176
0,176
5
0,2413905
15,774
535,3
535,9
101,07
100,79
0,175
0,176
6
0,2443137
15,671
535,3
535,9
101,32
101,28
0,174
0,176
7
0,2428569
15,788
535,3
536,0
100,53
100,25
0,174
0,176
8
0,2447754
15,594
535,4
536,0
101,48
101,52
0,173
0,176
9
0,2418091
15,523
535,4
536,0
103,44
101,65
0,175
0,176
10
0,2407581
15,592
535,4
536,0
101,22
101,92
0,174
0,176
11
0,2418094
15,522
535,4
536,0
102,08
102,04
0,173
0,176
12
0,2407584
15,519
535,4
536,0
102,45
101,90
0,174
0,176
13
0,2407584
15,593
535,4
536,0
100,96
101,94
0,173
0,176
14
0,2418097
15,607
535,4
536,0
101,29
101,89
0,173
0,176
15
0,2418106
15,679
535,4
536,0
101,01
101,56
0,173
0,176
16
0,2428565
15,589
535,5
536,1
103,40
101,49
0,174
0,176
17
0,2413906
15,552
535,5
536,1
101,61
102,36
0,174
0,176
18
0,2407589
15,552
535,5
536,1
103,72
101,52
0,174
0,176
19
0,2407587
15,782
535,5
536,1
102,19
100,17
0,176
0,175
20
0,2443144
15,591
535,5
536,1
101,31
102,13
0,174
0,176
21
0,2413905
15,622
535,4
536,1
101,45
101,76
0,173
0,176
22
0,2418096
15,617
535,4
536,1
102,87
101,55
0,174
0,176
23
0,2418096
15,698
535,4
536,1
102,90
101,05
0,176
0,176
24
0,2428567
15,697
535,4
536,1
100,23
101,58
0,174
0,176
25
0,2428572
15,633
535,5
536,1
100,73
101,79
0,171
0,176
26
0,24181
15,603
535,5
536,1
101,06
102,26
0,172
0,176
27
0,2413904
15,605
535,5
536,2
101,91
101,97
0,173
0,176
28
0,2413901
15,567
535,6
536,2
101,62
102,22
0,173
0,176
29
0,2407586
15,567
535,6
536,2
102,34
102,16
0,173
0,176
30
0,2408328
15,563
535,6
536,2
101,03
102,36
0,172
0,176
31
0,2407589
15,727
535,6
536,2
102,26
101,02
0,173
0,176
32
0,2432742
15,518
535,6
536,3
101,93
102,50
0,174
0,176
33
0,239915
15,799
535,7
536,3
102,33
100,40
0,174
0,175
34
0,2443146
15,611
535,7
536,4
103,45
101,67
0,176
0,175
35
0,241391
15,541
535,8
536,4
103,80
101,98
0,176
0,175
36
0,2403381
15,571
535,8
536,4
101,67
102,01
0,174
0,175
37
0,2407586
15,571
535,8
536,4
103,27
101,64
0,174
0,175
38
0,2407585
15,570
535,8
536,4
101,22
102,27
0,173
0,175
39
0,240759
15,568
535,8
536,5
103,03
102,29
0,173
0,176
40
0,2407589
15,643
535,8
536,5
100,65
102,18
0,173
0,176
41
0,2418102
15,521
535,9
536,5
101,17
102,89
0,171
0,176
42
0,239917
15,643
535,9
536,5
100,60
102,22
0,171
0,176
43
0,2418103
15,616
536,0
536,6
100,60
102,20
0,171
0,176
44
0,2413799
15,578
536,0
536,6
102,02
102,62
0,172
0,176
45
0,2407593
15,616
536,0
536,6
103,05
101,59
0,174
0,176
46
0,2413902
15,706
536,0
536,6
100,65
101,03
0,174
0,175
47
0,2428569
15,730
536,0
536,6
101,51
100,70
0,173
0,175
48
0,2432737
15,607
536,0
536,6
101,76
101,59
0,173
0,175
49
0,241391
15,610
536,0
536,6
102,24
101,40
0,173
0,175
50
0,2413904
15,638
536,0
536,6
102,76
101,40
0,174
0,175
51
0,2418099
15,570
536,1
536,7
101,05
102,03
0,173
0,175
52
0,2407591
15,514
536,1
536,7
103,40
102,91
0,173
0,176
53
0,2399147
Proportional Rates
Particulates Calculations
Page 1 of 5
DATA 2018-01-16 EPA PI 20162 RUN 2 CAT 2 MODEL GM 60
15,468
536,1
536,7
101,62
102,78
0,173
0,176
54
0,2392794
15,561
536,1
536,7
101,82
101,98
0,172
0,176
55
0,2407617
15,605
536,1
536,7
102,96
101,66
0,174
0,175
56
0,2413909
15,559
536,1
536,7
100,97
102,23
0,173
0,176
57
0,2407587
15,553
536,0
536,7
103,24
101,70
0,173
0,176
58
0,2407588
15,606
536,1
536,7
103,05
101,80
0,175
0,175
59
0,2413907
15,728
536,0
536,7
101,68
101,04
0,175
0,176
60
0,2432738
15,607
536,1
536,8
101,31
102,54
0,173
0,176
61
0,2413831
15,562
536,1
536,8
101,40
101,91
0,172
0,176
62
0,2407589
15,698
536,2
536,8
102,04
100,78
0,173
0,175
63
0,2428577
15,791
536,2
536,9
99,78
100,06
0,173
0,175
64
0,2443139
15,531
536,2
536,8
103,25
102,00
0,173
0,175
65
0,2403625
15,594
536,2
536,9
102,45
101,96
0,175
0,176
66
0,2413903
15,553
536,2
536,9
100,89
102,16
0,173
0,176
67
0,2407778
15,597
536,2
536,9
102,82
101,66
0,173
0,176
68
0,241391
15,427
536,2
536,9
102,07
102,50
0,173
0,175
69
0,2387501
15,556
536,3
536,9
100,91
102,60
0,171
0,176
70
0,2407594
15,595
536,3
536,9
100,12
101,67
0,171
0,176
71
0,2413907
15,554
536,3
537,0
102,82
102,18
0,172
0,176
72
0,2407595
15,687
536,3
537,0
100,07
100,89
0,173
0,176
73
0,2428572
15,550
536,3
536,9
101,36
101,65
0,172
0,175
74
0,2407591
15,587
536,3
537,0
102,21
101,91
0,173
0,176
75
0,2413911
15,679
536,3
537,0
99,99
100,89
0,173
0,176
76
0,2428574
15,675
536,3
536,9
101,26
101,61
0,172
0,176
77
0,2428575
15,708
536,3
536,9
99,98
101,34
0,172
0,177
78
0,2432746
15,681
536,3
536,9
100,08
100,79
0,171
0,176
79
0,2428573
15,585
536,3
537,0
102,50
101,60
0,173
0,175
80
0,2413906
15,537
536,3
537,0
100,75
101,98
0,173
0,176
81
0,2407596
15,577
536,3
537,0
100,52
102,03
0,171
0,176
82
0,2413901
15,531
536,3
537,0
101,34
102,45
0,172
0,176
83
0,2407597
15,595
536,3
537,0
100,41
101,80
0,172
0,177
84
0,2418106
15,566
536,3
536,9
100,87
100,95
0,172
0,175
85
0,2413915
15,521
536,2
536,9
103,02
102,24
0,174
0,176
86
0,2407592
15,660
536,3
536,9
100,77
100,73
0,174
0,176
87
0,2428581
15,592
536,2
536,9
102,27
101,68
0,174
0,176
88
0,2418522
15,563
536,2
536,9
101,06
101,25
0,173
0,176
89
0,241391
15,521
536,3
536,9
103,31
102,06
0,174
0,176
90
0,2407593
15,518
536,3
537,0
100,92
101,37
0,174
0,176
91
0,2407595
15,679
536,3
537,0
99,82
101,03
0,172
0,176
92
0,2432751
15,579
536,3
537,0
101,95
101,32
0,173
0,176
93
0,2418109
15,872
536,3
537,0
99,20
99,32
0,173
0,176
94
0,2463835
15,803
536,3
536,9
98,50
99,75
0,172
0,176
95
0,2453514
15,573
536,2
536,9
102,19
102,09
0,173
0,176
96
0,2418108
15,505
536,2
536,9
101,65
101,63
0,174
0,176
97
0,2407602
15,548
536,3
536,9
101,19
101,13
0,173
0,175
98
0,2413911
15,569
536,3
536,9
101,48
101,71
0,173
0,176
99
0,2418103
15,540
536,3
536,9
101,10
101,59
0,173
0,176
100
0,2413917
15,632
536,3
537,0
101,97
100,66
0,174
0,176
101
0,242857
15,558
536,3
536,9
101,97
101,58
0,175
0,176
102
0,2418107
15,487
536,2
536,9
102,80
101,51
0,175
0,176
103
0,2407599
15,614
536,2
536,9
101,71
100,71
0,175
0,176
104
0,2428579
15,548
536,2
536,9
99,82
100,94
0,173
0,176
105
0,2418099
15,549
536,2
536,9
100,59
101,01
0,172
0,175
106
0,2418109
15,611
536,1
536,8
101,52
100,69
0,173
0,176
107
0,2428568
15,519
536,1
536,8
101,86
101,72
0,174
0,176
108
0,2413917
15,608
536,1
536,8
99,99
100,24
0,173
0,176
109
0,2428575
15,703
536,1
536,8
101,61
100,31
0,174
0,176
110
0,2443151
15,604
536,1
536,8
100,09
100,33
0,174
0,176
111
0,2428576
15,507
536,1
536,8
99,91
100,99
0,172
0,175
112
0,2413906
15,628
536,1
536,8
99,34
100,15
0,171
0,175
113
0,2432747
15,626
536,1
536,8
101,05
100,46
0,173
0,176
114
0,2432748
Particulates Calculations
Page 2 of 5
DATA 2018-01-16 EPA PI 20162 RUN 2 CAT 2 MODEL GM 60
15,785
536,0
536,8
100,28
99,42
0,174
0,176
115
0,2457639
15,626
536,0
536,7
99,62
100,52
0,173
0,176
116
0,2432745
15,734
536,0
536,7
100,80
99,86
0,173
0,176
117
0,2449369
15,597
536,0
536,7
101,86
100,91
0,175
0,176
118
0,2428574
15,729
536,0
536,7
98,55
99,22
0,173
0,176
119
0,2449371
15,726
536,0
536,7
100,71
100,25
0,173
0,176
120
0,2449236
15,493
536,0
536,7
101,08
101,47
0,174
0,177
121
0,2413911
15,615
535,9
536,7
101,41
100,57
0,174
0,176
122
0,2432744
15,614
535,9
536,6
101,61
100,41
0,175
0,176
123
0,2432744
15,772
535,9
536,6
100,43
99,25
0,175
0,176
124
0,245805
15,621
535,9
536,6
99,75
100,61
0,174
0,176
125
0,2432744
15,683
535,8
536,6
99,04
99,94
0,172
0,176
126
0,2443145
15,613
535,9
536,6
99,55
99,92
0,172
0,175
127
0,2432745
15,611
535,9
536,6
101,04
100,65
0,173
0,176
128
0,2432742
15,514
535,9
536,6
99,60
100,93
0,173
0,176
129
0,2418104
15,674
535,8
536,5
100,91
100,10
0,173
0,176
130
0,2443146
15,673
535,8
536,5
101,05
100,50
0,175
0,176
131
0,2443151
15,578
535,8
536,5
99,38
100,39
0,173
0,176
132
0,242858
15,600
535,8
536,5
99,23
100,10
0,171
0,176
133
0,2432746
15,607
535,8
536,5
101,95
100,74
0,174
0,176
134
0,2432744
15,712
535,7
536,4
100,80
99,83
0,176
0,176
135
0,2449371
15,715
535,8
536,4
100,52
99,95
0,175
0,176
136
0,2449366
15,716
535,8
536,4
98,76
99,54
0,173
0,176
137
0,2450567
15,707
535,8
536,4
99,41
99,62
0,172
0,176
138
0,2449371
15,761
535,8
536,4
100,14
99,49
0,174
0,176
139
0,2457644
15,600
535,8
536,4
98,94
100,19
0,173
0,176
140
0,2432741
15,437
535,7
536,4
102,65
101,95
0,173
0,176
141
0,2407593
15,730
535,7
536,4
98,45
99,39
0,174
0,176
142
0,2453511
15,662
535,6
536,3
99,85
99,83
0,172
0,176
143
0,2443151
15,581
535,6
536,3
101,24
100,83
0,174
0,176
144
0,2428579
15,509
535,6
536,3
102,16
101,21
0,175
0,176
145
0,2418097
15,440
535,7
536,3
100,26
100,75
0,173
0,176
146
0,2407592
15,600
535,7
536,3
101,31
100,55
0,173
0,175
147
0,243274
15,666
535,7
536,3
101,06
100,14
0,175
0,176
148
0,2443151
15,597
535,7
536,3
99,12
99,81
0,173
0,176
149
0,243274
15,593
535,6
536,3
101,81
100,72
0,174
0,176
150
0,2432737
15,431
535,6
536,3
102,03
101,68
0,175
0,177
151
0,2407659
15,699
535,6
536,3
100,90
99,75
0,175
0,176
152
0,2449369
15,436
535,6
536,3
100,96
101,43
0,174
0,176
153
0,240759
15,477
535,6
536,3
102,38
101,34
0,174
0,176
154
0,2413911
15,601
535,6
536,3
99,28
100,29
0,173
0,176
155
0,2432741
15,503
535,6
536,3
101,44
101,12
0,173
0,176
156
0,2418104
15,580
535,6
536,3
100,90
100,62
0,174
0,176
157
0,2430075
15,793
535,6
536,3
97,85
98,60
0,173
0,176
158
0,2463826
15,750
535,6
536,3
98,74
99,30
0,172
0,176
159
0,2457634
15,694
535,6
536,3
100,68
100,15
0,174
0,176
160
0,2449361
15,721
535,5
536,2
100,65
100,05
0,175
0,177
161
0,2453507
15,492
535,5
536,2
101,93
101,14
0,175
0,177
162
0,2418098
15,507
535,5
536,2
101,44
101,06
0,175
0,176
163
0,2418099
15,757
535,4
536,1
99,78
99,51
0,174
0,176
164
0,2457632
15,594
535,4
536,1
101,71
100,58
0,175
0,176
165
0,2432739
15,698
535,5
536,1
98,65
99,61
0,174
0,176
166
0,2449363
15,656
535,5
536,1
98,94
99,76
0,172
0,176
167
0,2443143
15,655
535,4
536,1
100,82
100,17
0,173
0,176
168
0,2443157
15,691
535,4
536,1
100,60
100,04
0,175
0,177
169
0,2449364
15,717
535,4
536,1
98,51
99,04
0,173
0,176
170
0,2453505
15,582
535,3
536,0
101,68
100,70
0,174
0,176
171
0,2432739
15,472
535,3
536,0
100,03
101,12
0,174
0,176
172
0,2413904
15,750
535,3
536,0
98,21
99,06
0,171
0,176
173
0,245762
15,701
535,4
536,0
100,98
100,00
0,174
0,176
174
0,2449363
15,700
535,4
536,0
101,00
100,09
0,176
0,177
175
0,2449362
Particulates Calculations
Page 3 of 5
DATA 2018-01-16 EPA PI 20162 RUN 2 CAT 2 MODEL GM 60
15,372
535,4
536,0
102,50
102,00
0,175
0,177
176
0,2399146
15,561
535,4
536,0
99,86
100,23
0,174
0,176
177
0,2428569
15,650
535,4
536,0
100,29
99,70
0,173
0,176
178
0,2443136
15,715
535,3
536,0
100,75
100,00
0,175
0,176
179
0,2453506
15,710
535,3
535,9
100,69
99,53
0,176
0,177
180
0,2453509
15,555
535,2
535,9
99,30
100,13
0,174
0,176
181
0,2428576
15,709
535,2
535,9
100,87
99,89
0,173
0,176
182
0,2449362
15,566
535,2
535,9
101,75
100,80
0,175
0,176
183
0,2428566
15,589
535,2
535,9
99,30
99,85
0,174
0,176
184
0,2432738
15,695
535,2
535,9
98,68
99,52
0,172
0,175
185
0,2449369
15,692
535,2
535,9
99,08
99,69
0,172
0,176
186
0,2449358
15,688
535,2
535,9
101,01
99,97
0,174
0,176
187
0,2449053
15,687
535,2
535,8
98,54
99,63
0,174
0,176
188
0,244936
15,686
535,2
535,8
100,59
100,02
0,173
0,176
189
0,2449361
15,578
535,2
535,8
99,61
100,48
0,174
0,177
190
0,2432735
15,568
535,2
535,8
99,68
100,48
0,172
0,176
191
0,2428565
15,499
535,2
535,8
99,99
100,87
0,172
0,176
192
0,2418096
15,741
535,2
535,8
99,76
99,60
0,173
0,176
193
0,2456173
15,724
535,2
535,8
98,39
99,41
0,173
0,176
194
0,2453507
15,692
535,2
535,8
98,35
99,33
0,171
0,176
195
0,2449425
15,689
535,2
535,8
98,59
99,50
0,171
0,176
196
0,2449359
15,781
535,2
535,8
100,44
99,27
0,174
0,176
197
0,2463819
15,648
535,1
535,8
100,99
100,41
0,176
0,177
198
0,2443139
15,551
535,1
535,7
99,57
100,45
0,174
0,176
199
0,2428565
15,559
535,1
535,7
100,36
100,26
0,173
0,176
200
0,2428741
15,750
535,1
535,7
98,86
99,73
0,173
0,176
201
0,2457626
15,590
535,1
535,7
101,29
100,10
0,174
0,176
202
0,2432741
15,561
535,1
535,7
101,68
100,93
0,175
0,176
203
0,2428569
15,691
535,2
535,7
100,47
100,24
0,175
0,177
204
0,2449358
15,689
535,1
535,7
100,51
100,49
0,175
0,177
205
0,2449358
15,688
535,1
535,7
98,51
99,61
0,173
0,177
206
0,2449353
15,738
535,1
535,7
98,36
98,81
0,172
0,176
207
0,2457631
15,709
535,0
535,7
98,62
99,51
0,172
0,176
208
0,2453503
15,463
535,0
535,6
101,22
100,95
0,173
0,176
209
0,2413898
15,567
535,0
535,6
101,40
101,19
0,174
0,176
210
0,2428566
15,748
535,0
535,6
98,29
99,45
0,173
0,177
211
0,2457622
15,655
535,0
535,6
98,95
100,07
0,172
0,176
212
0,2443131
15,422
535,0
535,6
102,70
101,53
0,174
0,176
213
0,240758
15,740
535,1
535,7
98,83
99,37
0,174
0,176
214
0,2457199
15,685
535,0
535,6
100,85
100,22
0,174
0,177
215
0,244936
15,706
535,0
535,6
98,48
99,14
0,174
0,176
216
0,2453502
15,481
534,9
535,5
102,09
101,38
0,174
0,176
217
0,2418087
15,688
534,9
535,5
98,95
99,91
0,174
0,177
218
0,2449359
15,568
534,9
535,5
99,60
100,60
0,172
0,176
219
0,2428561
15,693
534,9
535,6
98,63
99,61
0,172
0,176
220
0,2449355
15,688
534,9
535,6
99,40
99,22
0,172
0,176
221
0,244936
15,646
535,0
535,6
101,52
100,19
0,175
0,176
222
0,2443143
15,576
534,9
535,5
101,55
100,42
0,176
0,176
223
0,2432734
15,734
534,9
535,5
98,88
99,85
0,174
0,177
224
0,2457634
15,733
534,9
535,5
100,55
99,55
0,174
0,177
225
0,2457627
15,477
534,9
535,5
102,31
101,12
0,176
0,177
226
0,241809
15,553
534,9
535,5
101,41
100,38
0,176
0,176
227
0,2429213
15,749
534,9
535,5
100,62
99,84
0,175
0,176
228
0,2457634
15,651
534,9
535,5
101,27
100,23
0,176
0,177
229
0,2443134
15,581
534,9
535,5
101,53
100,22
0,176
0,176
230
0,2432729
15,710
534,9
535,5
99,12
99,98
0,174
0,176
231
0,2453504
15,773
534,9
535,5
100,57
99,32
0,175
0,177
232
0,2463814
15,572
534,9
535,5
99,69
100,10
0,174
0,176
233
0,2432726
15,701
534,9
535,4
100,53
99,86
0,174
0,176
234
0,2453502
15,702
534,8
535,4
101,10
99,57
0,176
0,177
235
0,2453502
15,455
534,8
535,4
99,96
101,46
0,174
0,177
236
0,2413894
Particulates Calculations
Page 4 of 5
DATA 2018-01-16 EPA PI 20162 RUN 2 CAT 2 MODEL GM 60
15,724
534,8
535,4
101,06
99,64
0,174
0,177
237
0,2454725
15,645
534,8
535,4
99,01
100,23
0,174
0,177
238
0,2443132
15,645
534,8
535,4
99,29
99,65
0,172
0,176
239
0,244313
15,798
534,9
535,4
100,29
99,00
0,174
0,176
240
0,246793
15,636
534,8
535,4
99,22
99,77
0,174
0,176
241
0,2443136
15,636
534,8
535,4
101,38
100,29
0,174
0,176
242
0,2443128
Particulates Calculations
Page 5 of 5
DATA 2018-01-17 EPA PI 20162 RUN 3 CAT 2 MODEL GM 60 NO FAN
Average
Average
Average
Average
15,34
Inlet +
Inlet +
0,238
Outlet
Outlet
Average
Average
#1
#2
Tunnel
Temp.
Temp.
100,67
100,93
System 1
System 2
SQRT
Velocity
Meter 1
Meter 2
Vol.Std.
Vol.Std.
Delta-P
PR1
PR2
Time
Ft/Sec
Deg. R
Deg. R
%%
(ft3)
(ft3)
min
(in H2O)2
15,722
534,9
535,6
0,168
0,180
0
0,2377912
15,614
535,0
535,6
101,75
100,77
0,172
0,178
1
0,2407583
15,430
535,0
535,6
99,04
101,90
0,172
0,175
2
0,2377914
15,454
535,1
535,7
103,21
101,98
0,172
0,175
3
0,2377908
15,372
535,2
535,7
103,38
101,55
0,176
0,175
4
0,2377908
15,417
535,2
535,7
100,75
100,93
0,175
0,176
5
0,239279
15,335
535,2
535,7
101,23
101,10
0,174
0,176
6
0,2382165
15,328
535,2
535,7
101,93
101,03
0,174
0,175
7
0,2382166
15,318
535,2
535,8
102,66
100,83
0,176
0,175
8
0,2382166
15,429
535,2
535,7
102,08
99,97
0,176
0,175
9
0,239914
15,326
535,1
535,7
100,65
101,38
0,175
0,176
10
0,2382168
15,347
535,2
535,8
102,77
100,84
0,175
0,176
11
0,2382168
15,390
535,2
535,8
100,09
101,19
0,174
0,175
12
0,238855
15,387
535,2
535,8
100,16
101,28
0,172
0,176
13
0,2388553
15,382
535,3
535,8
102,13
100,57
0,174
0,176
14
0,238855
15,385
535,3
535,9
100,99
100,91
0,175
0,175
15
0,2388553
15,314
535,3
535,9
100,66
101,41
0,173
0,176
16
0,2377916
15,325
535,3
535,9
101,68
101,59
0,173
0,176
17
0,2377914
15,332
535,3
535,9
102,61
100,83
0,175
0,175
18
0,2377909
15,336
535,3
535,9
100,64
101,34
0,174
0,175
19
0,2377911
15,566
535,3
535,9
101,27
99,50
0,174
0,175
20
0,2413901
15,365
535,3
535,9
100,23
101,91
0,174
0,176
21
0,2382166
15,485
535,4
535,9
99,75
100,85
0,172
0,176
22
0,2399141
15,415
535,4
536,0
102,11
100,83
0,174
0,175
23
0,2388552
15,378
535,5
536,0
100,79
101,31
0,174
0,175
24
0,2382408
15,449
535,5
536,0
101,95
100,88
0,174
0,175
25
0,2392792
15,371
535,5
536,0
102,14
101,15
0,175
0,175
26
0,2382168
15,376
535,4
536,1
102,58
100,78
0,175
0,175
27
0,2382166
15,353
535,4
536,0
100,60
101,97
0,174
0,175
28
0,2377915
15,357
535,4
536,0
100,50
102,22
0,172
0,176
29
0,237799
15,429
535,5
536,1
99,79
101,45
0,171
0,176
30
0,2388551
15,368
535,5
536,1
100,34
102,16
0,171
0,176
31
0,2377912
15,375
535,6
536,1
101,83
101,84
0,172
0,176
32
0,2377914
15,404
535,6
536,2
100,40
101,80
0,173
0,176
33
0,2382169
15,405
535,6
536,2
102,70
101,43
0,173
0,176
34
0,2382168
15,450
535,6
536,2
102,06
101,03
0,175
0,175
35
0,2388553
15,387
535,7
536,2
102,35
101,74
0,175
0,175
36
0,2377911
15,382
535,7
536,3
103,13
101,51
0,175
0,175
37
0,2377916
15,055
535,7
536,3
104,81
103,65
0,175
0,175
38
0,2326166
15,463
535,7
536,3
100,16
101,70
0,173
0,175
39
0,2388547
15,418
535,7
536,3
100,53
102,26
0,171
0,176
40
0,2382172
15,426
535,8
536,3
100,54
102,48
0,172
0,177
41
0,2382172
15,400
535,8
536,4
100,83
101,91
0,172
0,176
42
0,2377917
15,429
535,9
536,5
101,95
101,96
0,173
0,176
43
0,2382155
15,434
535,9
536,5
102,29
101,50
0,174
0,176
44
0,2382173
15,407
535,9
536,5
102,60
101,21
0,175
0,175
45
0,2377918
15,402
535,9
536,6
100,02
102,15
0,172
0,175
46
0,2377914
15,372
536,0
536,6
101,57
101,80
0,171
0,175
47
0,2373644
15,300
536,0
536,6
101,42
102,30
0,172
0,175
48
0,2362942
15,428
536,0
536,6
101,97
101,69
0,173
0,175
49
0,2382171
15,423
536,0
536,6
100,37
101,57
0,173
0,175
50
0,2382172
15,472
536,0
536,6
100,23
101,30
0,171
0,175
51
0,2388562
15,396
536,1
536,7
100,50
102,31
0,171
0,176
52
0,2377922
Proportional Rates
Particulates Calculations
Page 1 of 5
DATA 2018-01-17 EPA PI 20162 RUN 3 CAT 2 MODEL GM 60 NO FAN
15,394
536,1
536,7
99,97
102,13
0,171
0,176
53
0,2377921
15,435
536,1
536,8
102,69
101,69
0,173
0,176
54
0,2382174
15,399
536,2
536,8
101,60
102,11
0,174
0,176
55
0,2377915
15,398
536,2
536,8
100,46
101,98
0,172
0,176
56
0,2377916
15,330
536,2
536,8
102,49
101,84
0,172
0,175
57
0,2367223
15,358
536,2
536,8
100,38
102,08
0,172
0,175
58
0,2373645
15,416
536,1
536,8
102,12
101,74
0,173
0,176
59
0,2382178
15,390
536,2
536,8
102,64
101,82
0,175
0,176
60
0,2377923
15,402
536,2
536,8
100,39
102,17
0,173
0,176
61
0,2377922
15,429
536,3
536,9
101,45
101,10
0,172
0,175
62
0,2382176
15,373
536,3
537,0
100,47
102,02
0,172
0,175
63
0,2373647
15,434
536,3
537,0
99,68
101,85
0,170
0,176
64
0,2382177
15,430
536,3
537,0
101,32
101,95
0,171
0,176
65
0,2382174
15,393
536,3
537,0
102,83
101,54
0,174
0,175
66
0,2377919
15,393
536,3
537,0
102,04
101,82
0,174
0,175
67
0,2378124
15,361
536,3
537,0
100,95
101,51
0,173
0,175
68
0,2373648
15,388
536,4
537,0
100,31
102,21
0,171
0,175
69
0,2377921
15,578
536,4
537,0
101,01
100,24
0,173
0,176
70
0,2407594
15,392
536,4
537,0
102,53
101,41
0,174
0,175
71
0,2377921
15,391
536,4
537,1
102,65
101,86
0,175
0,175
72
0,2377926
15,385
536,5
537,1
100,51
102,06
0,173
0,176
73
0,2377925
15,400
536,5
537,1
100,34
101,80
0,171
0,176
74
0,2378793
15,419
536,5
537,2
101,16
100,88
0,172
0,175
75
0,238218
15,413
536,5
537,2
99,92
101,56
0,172
0,175
76
0,2382176
15,114
536,5
537,2
103,82
103,29
0,172
0,175
77
0,2337044
15,381
536,5
537,2
100,73
101,17
0,173
0,175
78
0,2377924
15,399
536,5
537,2
102,36
101,14
0,173
0,175
79
0,2382173
15,506
536,5
537,1
99,58
100,25
0,173
0,175
80
0,239915
15,387
536,5
537,1
100,06
101,39
0,171
0,175
81
0,2382178
15,466
536,5
537,2
99,24
100,96
0,171
0,175
82
0,2392639
15,389
536,5
537,2
101,25
101,72
0,172
0,176
83
0,2382182
15,362
536,5
537,2
100,10
101,65
0,172
0,176
84
0,237793
15,366
536,5
537,2
101,55
101,24
0,172
0,175
85
0,237793
15,353
536,6
537,3
99,72
101,22
0,172
0,175
86
0,237793
15,345
536,6
537,3
100,23
101,06
0,171
0,175
87
0,2377929
15,344
536,5
537,2
101,49
101,76
0,172
0,175
88
0,2377929
15,364
536,5
537,2
99,86
101,38
0,172
0,176
89
0,2382188
15,364
536,5
537,2
99,70
101,12
0,171
0,175
90
0,2382187
15,475
536,5
537,2
98,72
100,27
0,171
0,175
91
0,2399162
15,435
536,4
537,1
100,91
100,52
0,172
0,175
92
0,2392805
15,333
536,5
537,1
99,93
101,29
0,172
0,175
93
0,2377929
15,334
536,5
537,2
100,01
101,35
0,171
0,175
94
0,2377931
15,360
536,5
537,2
101,84
101,14
0,173
0,175
95
0,2382182
15,356
536,5
537,2
101,68
101,07
0,174
0,175
96
0,2382182
15,251
536,4
537,1
100,39
101,14
0,173
0,175
97
0,2367229
15,318
536,3
537,1
100,00
100,76
0,171
0,174
98
0,2377929
15,342
536,3
537,0
101,36
100,55
0,173
0,174
99
0,2382185
15,312
536,3
537,0
100,04
101,36
0,173
0,175
100
0,2377924
15,450
536,2
537,0
100,87
100,96
0,173
0,176
101
0,2399152
15,316
536,2
537,0
101,95
101,26
0,174
0,176
102
0,2377926
15,411
536,2
536,9
101,36
100,40
0,175
0,175
103
0,2392803
15,316
536,2
537,0
99,49
101,21
0,172
0,175
104
0,2377929
15,312
536,2
537,0
99,57
101,12
0,170
0,175
105
0,2377923
15,315
536,2
536,9
101,84
101,53
0,173
0,176
106
0,2378887
15,306
536,2
536,9
102,15
101,45
0,175
0,176
107
0,2377926
15,273
536,2
536,9
102,02
101,28
0,175
0,176
108
0,237365
15,326
536,2
536,9
100,53
100,62
0,174
0,175
109
0,2382175
15,327
536,2
536,9
99,94
100,93
0,172
0,175
110
0,2382177
15,360
536,2
536,9
99,52
100,22
0,172
0,175
111
0,2388566
15,288
536,1
536,9
99,16
100,74
0,171
0,175
112
0,2377922
15,366
536,1
536,9
101,33
100,55
0,172
0,175
113
0,238859
Particulates Calculations
Page 2 of 5
DATA 2018-01-17 EPA PI 20162 RUN 3 CAT 2 MODEL GM 60 NO FAN
15,320
536,1
536,9
101,59
100,87
0,174
0,175
114
0,2382179
15,319
536,1
536,9
99,43
100,80
0,173
0,175
115
0,2382181
15,295
536,1
536,9
99,52
100,79
0,171
0,175
116
0,2377929
15,294
536,1
536,9
101,69
101,13
0,172
0,175
117
0,2377923
15,295
536,1
536,9
100,89
101,18
0,174
0,175
118
0,2377924
15,314
536,1
536,9
101,83
101,08
0,174
0,176
119
0,238218
15,418
536,1
536,9
100,74
100,79
0,175
0,176
120
0,2399153
15,538
536,1
536,8
99,97
99,24
0,174
0,176
121
0,2418109
15,304
536,0
536,8
99,03
100,36
0,172
0,175
122
0,2382178
15,484
536,1
536,8
98,65
99,66
0,171
0,175
123
0,2407594
15,311
536,1
536,9
101,50
100,99
0,173
0,175
124
0,2382181
15,351
536,1
536,9
99,19
100,36
0,173
0,175
125
0,2388565
15,358
536,1
536,8
99,89
100,70
0,172
0,175
126
0,2388566
15,309
536,1
536,9
99,18
100,18
0,171
0,175
127
0,2382184
15,276
536,1
536,9
99,61
100,80
0,171
0,175
128
0,2377927
15,376
536,1
536,8
101,11
100,62
0,173
0,175
129
0,2392802
15,338
536,1
536,8
101,12
100,45
0,175
0,176
130
0,2388563
15,373
536,1
536,8
99,21
100,39
0,173
0,175
131
0,2392807
15,277
536,1
536,8
100,22
101,18
0,172
0,176
132
0,2377929
15,283
536,1
536,8
99,61
100,72
0,171
0,175
133
0,237792
15,302
536,1
536,8
101,83
101,41
0,173
0,176
134
0,2382184
15,311
536,1
536,9
100,89
100,76
0,174
0,176
135
0,238218
15,281
536,1
536,8
101,82
101,40
0,174
0,176
136
0,2377924
15,307
536,1
536,8
101,49
101,04
0,175
0,176
137
0,2382182
15,274
536,1
536,9
99,99
100,70
0,173
0,175
138
0,2377923
15,466
536,1
536,8
100,31
99,68
0,173
0,175
139
0,2407593
15,368
536,1
536,8
98,97
100,30
0,173
0,175
140
0,2392804
15,364
536,1
536,8
99,26
100,17
0,171
0,175
141
0,2392806
15,366
536,0
536,8
100,74
100,48
0,173
0,175
142
0,2392804
15,295
536,0
536,8
99,27
100,28
0,172
0,175
143
0,2382178
15,372
536,0
536,8
100,42
100,13
0,172
0,175
144
0,2392801
15,340
536,0
536,8
98,98
100,08
0,172
0,175
145
0,2388563
15,297
536,0
536,8
101,66
101,45
0,173
0,176
146
0,2382177
15,266
536,0
536,8
101,05
100,93
0,174
0,176
147
0,237793
15,233
536,0
536,8
101,63
101,68
0,174
0,176
148
0,2373649
15,262
536,0
536,8
101,63
101,00
0,174
0,176
149
0,2377929
15,294
535,9
536,7
101,63
101,10
0,175
0,176
150
0,2382178
15,287
535,9
536,7
101,53
100,83
0,175
0,176
151
0,2382186
15,398
535,9
536,7
98,54
99,85
0,173
0,175
152
0,2399155
15,356
535,8
536,6
98,56
99,89
0,171
0,175
153
0,239281
15,327
535,8
536,6
100,54
100,45
0,172
0,175
154
0,2388561
15,295
535,8
536,6
101,49
100,99
0,174
0,176
155
0,2382178
15,360
535,8
536,6
100,49
99,98
0,174
0,175
156
0,23928
15,327
535,8
536,6
100,99
100,48
0,174
0,175
157
0,2388566
15,253
535,7
536,6
99,81
101,03
0,173
0,176
158
0,2377921
15,256
535,7
536,6
101,19
101,10
0,173
0,176
159
0,2377921
15,277
535,7
536,5
100,47
100,60
0,173
0,176
160
0,2382176
15,281
535,7
536,5
101,23
101,00
0,174
0,176
161
0,2382509
15,264
535,7
536,5
101,28
100,75
0,174
0,176
162
0,2377922
15,513
535,7
536,5
99,29
99,27
0,174
0,175
163
0,2417846
15,396
535,7
536,4
98,60
99,83
0,172
0,175
164
0,2399152
15,399
535,7
536,4
100,94
100,85
0,173
0,176
165
0,239915
15,390
535,7
536,4
98,74
99,77
0,173
0,176
166
0,2399156
15,258
535,7
536,4
100,48
100,83
0,172
0,175
167
0,2377922
15,270
535,7
536,4
99,38
100,79
0,172
0,175
168
0,2377924
15,290
535,7
536,4
100,99
100,84
0,172
0,175
169
0,2382181
15,325
535,7
536,4
99,11
99,82
0,172
0,175
170
0,2388561
15,277
535,6
536,4
99,28
100,45
0,171
0,175
171
0,2382179
15,228
535,6
536,4
99,86
100,74
0,171
0,175
172
0,2373618
15,324
535,6
536,4
99,85
100,68
0,172
0,175
173
0,2388563
15,286
535,6
536,4
101,65
100,92
0,174
0,176
174
0,2382184
Particulates Calculations
Page 3 of 5
DATA 2018-01-17 EPA PI 20162 RUN 3 CAT 2 MODEL GM 60 NO FAN
15,323
535,6
536,3
99,21
100,49
0,173
0,176
175
0,2388566
15,353
535,6
536,4
101,24
100,44
0,173
0,176
176
0,2392798
15,287
535,6
536,4
99,30
100,84
0,173
0,176
177
0,2382177
15,255
535,6
536,4
99,44
100,82
0,171
0,175
178
0,2377922
15,275
535,6
536,3
99,34
100,47
0,171
0,175
179
0,2382169
15,254
535,5
536,3
101,44
100,67
0,173
0,175
180
0,2377984
15,283
535,5
536,3
101,18
101,29
0,174
0,176
181
0,2382175
15,246
535,5
536,2
100,35
100,72
0,173
0,176
182
0,2377921
15,267
535,4
536,2
101,04
100,43
0,173
0,175
183
0,2382171
15,505
535,4
536,2
99,08
98,98
0,174
0,175
184
0,2418101
15,252
535,4
536,2
101,72
101,16
0,174
0,176
185
0,2377917
15,344
535,5
536,2
101,03
100,43
0,175
0,176
186
0,2392799
15,286
535,5
536,2
101,15
101,00
0,174
0,176
187
0,2382175
15,281
535,5
536,2
99,49
100,89
0,173
0,176
188
0,2382173
15,351
535,5
536,2
98,81
100,25
0,171
0,176
189
0,2392795
15,278
535,5
536,3
99,24
100,58
0,171
0,175
190
0,2382172
15,279
535,5
536,3
100,06
101,01
0,172
0,176
191
0,2382172
15,250
535,5
536,2
101,47
101,13
0,173
0,176
192
0,2377918
15,249
535,5
536,2
101,23
101,42
0,174
0,176
193
0,2377917
15,344
535,5
536,2
98,86
100,00
0,173
0,176
194
0,2392795
15,277
535,4
536,2
100,14
100,18
0,172
0,175
195
0,2382174
15,389
535,4
536,2
100,17
99,69
0,173
0,175
196
0,2399143
15,349
535,5
536,2
98,90
99,98
0,172
0,175
197
0,2392799
15,340
535,5
536,2
100,62
100,68
0,173
0,176
198
0,2392792
15,245
535,5
536,2
100,54
100,29
0,174
0,175
199
0,2377919
15,388
535,5
536,2
100,88
100,55
0,174
0,175
200
0,2398786
15,278
535,4
536,2
101,65
101,08
0,175
0,176
201
0,2382172
15,172
535,4
536,2
100,01
101,20
0,173
0,176
202
0,2367219
15,240
535,4
536,2
101,55
101,00
0,173
0,176
203
0,2377917
15,267
535,4
536,1
101,28
101,14
0,175
0,176
204
0,2382175
15,378
535,4
536,1
98,51
100,03
0,173
0,176
205
0,2399148
15,268
535,4
536,1
101,73
100,93
0,173
0,176
206
0,238217
15,270
535,4
536,1
99,15
100,38
0,173
0,175
207
0,2382174
15,236
535,4
536,1
99,81
101,12
0,171
0,176
208
0,2377916
15,240
535,4
536,1
101,58
100,89
0,173
0,176
209
0,2377917
15,271
535,4
536,1
101,84
100,79
0,175
0,176
210
0,2382171
15,212
535,4
536,1
99,74
100,89
0,173
0,176
211
0,2373642
15,241
535,4
536,1
99,59
100,80
0,171
0,175
212
0,237792
15,238
535,4
536,1
99,42
100,63
0,171
0,175
213
0,2377933
15,233
535,4
536,1
101,57
101,05
0,173
0,176
214
0,2377914
15,423
535,4
536,1
97,87
99,72
0,173
0,176
215
0,2407587
15,264
535,3
536,0
99,06
100,39
0,171
0,175
216
0,2382165
15,337
535,3
536,0
100,85
100,32
0,173
0,175
217
0,239279
15,232
535,4
536,1
101,76
100,90
0,175
0,176
218
0,237792
15,231
535,3
536,1
101,07
100,97
0,175
0,176
219
0,2377931
15,235
535,3
536,0
99,62
100,91
0,173
0,176
220
0,2377915
15,234
535,3
536,0
99,90
100,51
0,172
0,175
221
0,2377915
15,259
535,2
536,0
100,84
100,18
0,173
0,175
222
0,2382172
15,227
535,2
536,0
99,42
100,70
0,173
0,175
223
0,2377919
15,261
535,2
536,0
101,79
100,60
0,173
0,175
224
0,2382176
15,492
535,2
535,9
99,71
99,34
0,175
0,176
225
0,2418099
15,233
535,2
535,9
100,78
100,45
0,174
0,175
226
0,2377921
15,426
535,2
535,9
98,22
99,28
0,172
0,175
227
0,2407886
15,259
535,2
535,9
99,73
101,25
0,172
0,176
228
0,2382174
15,235
535,3
536,0
101,82
100,96
0,174
0,176
229
0,2377915
15,225
535,2
535,9
99,71
101,17
0,173
0,176
230
0,2377919
15,294
535,2
535,9
101,24
100,33
0,173
0,176
231
0,2388554
15,293
535,2
535,9
101,13
99,89
0,175
0,175
232
0,2388552
15,229
535,2
535,9
101,45
100,31
0,175
0,175
233
0,2377919
15,259
535,2
535,9
99,10
100,18
0,173
0,175
234
0,2382169
15,299
535,1
535,9
99,22
100,19
0,171
0,175
235
0,2388552
Particulates Calculations
Page 4 of 5
DATA 2018-01-17 EPA PI 20162 RUN 3 CAT 2 MODEL GM 60 NO FAN
15,262
535,1
535,8
101,54
100,32
0,173
0,175
236
0,2382176
15,315
535,1
535,8
101,18
100,29
0,175
0,175
237
0,239035
15,325
535,2
535,9
99,51
99,95
0,174
0,175
238
0,2392792
15,255
535,2
535,9
99,39
100,34
0,172
0,175
239
0,2382171
15,365
535,2
535,9
100,22
100,07
0,173
0,175
240
0,2399143
15,258
535,2
535,9
99,55
100,94
0,173
0,176
241
0,238217
15,322
535,2
535,9
100,65
100,03
0,173
0,176
242
0,2392787
15,296
535,1
535,9
100,89
100,01
0,174
0,175
243
0,2388549
15,254
535,1
535,8
101,47
100,84
0,175
0,175
244
0,2382165
15,259
535,1
535,8
101,92
100,35
0,175
0,176
245
0,2382167
15,300
535,1
535,8
101,32
100,31
0,175
0,175
246
0,2388557
15,485
535,1
535,8
98,82
98,75
0,174
0,175
247
0,2418096
15,324
535,1
535,8
98,60
100,48
0,172
0,176
248
0,2392787
15,252
535,1
535,8
99,07
100,58
0,171
0,176
249
0,2382169
15,355
535,1
535,8
98,77
99,70
0,171
0,175
250
0,2399145
15,288
535,1
535,8
99,52
100,68
0,172
0,176
251
0,2388552
15,222
535,1
535,8
101,44
100,89
0,173
0,176
252
0,2377911
15,241
535,0
535,8
101,26
100,65
0,175
0,176
253
0,2382164
Particulates Calculations
Page 5 of 5
DATA 2018-01-18 EPA PI 20162 RUN 4 CAT 3 MODEL GM 60
Average
Average
Average
Average
15,16
Inlet +
Inlet +
0,234
Outlet
Outlet
Average
Average
#1
#2
Tunnel
Temp.
Temp.
100,35
99,83
System 1
System 2
SQRT
Velocity
Meter 1
Meter 2
Vol.Std.
Vol.Std.
Delta-P
PR1
PR2
Time
Ft/Sec
Deg. R
Deg. R
%%
(ft3)
(ft3)
min
(in H2O)2
15,743
536,5
537,0
0,170
0,174
0
0,2367208
15,576
536,5
537,0
100,15
99,61
0,171
0,174
1
0,2382169
15,526
536,4
537,0
96,33
99,70
0,168
0,174
2
0,2373633
15,574
536,4
537,0
99,50
99,95
0,167
0,174
3
0,2377907
15,450
536,4
537,0
101,53
100,88
0,171
0,174
4
0,2356473
15,309
536,3
537,0
103,30
100,26
0,173
0,174
5
0,2347853
15,418
536,3
537,0
100,04
99,71
0,173
0,174
6
0,2367213
15,412
536,3
537,0
102,03
99,17
0,173
0,173
7
0,2367217
15,493
536,3
537,0
99,69
99,06
0,173
0,173
8
0,237886
15,421
536,4
537,1
100,47
99,51
0,171
0,174
9
0,2367215
15,498
536,4
537,1
99,92
99,30
0,171
0,174
10
0,237803
15,360
536,4
537,1
100,27
100,70
0,171
0,174
11
0,235648
15,472
536,5
537,2
100,90
99,37
0,172
0,174
12
0,2373636
15,426
536,5
537,2
99,86
99,82
0,172
0,174
13
0,2367221
15,396
536,5
537,2
99,68
99,66
0,170
0,174
14
0,2362931
15,472
536,5
537,3
100,84
99,46
0,171
0,174
15
0,2373638
15,470
536,5
537,3
100,86
99,40
0,173
0,174
16
0,237364
15,431
536,5
537,3
100,70
99,51
0,172
0,174
17
0,2367222
15,503
536,5
537,3
99,69
98,98
0,171
0,173
18
0,2377914
15,473
536,5
537,3
99,25
99,73
0,170
0,174
19
0,2373635
15,534
536,6
537,4
99,23
98,91
0,170
0,174
20
0,2382173
15,486
536,7
537,4
99,43
99,41
0,170
0,173
21
0,2373638
15,414
536,7
537,4
99,27
99,74
0,170
0,173
22
0,2362938
15,415
536,8
537,5
101,25
99,79
0,171
0,173
23
0,2362963
15,376
536,8
537,5
101,94
99,48
0,173
0,173
24
0,2356488
15,146
536,9
537,6
102,05
101,75
0,172
0,173
25
0,2319607
15,146
536,8
537,6
103,15
102,03
0,171
0,174
26
0,2319609
15,189
536,8
537,6
103,41
101,23
0,173
0,174
27
0,2326161
15,187
536,9
537,6
100,80
101,43
0,171
0,173
28
0,2326163
15,116
536,9
537,6
102,74
102,01
0,170
0,174
29
0,2315226
15,081
536,9
537,6
103,75
101,98
0,172
0,173
30
0,2310849
15,180
537,0
537,7
102,99
101,27
0,173
0,173
31
0,2326161
15,144
537,0
537,7
102,03
101,60
0,171
0,173
32
0,2319608
14,918
537,1
537,8
102,92
103,77
0,170
0,174
33
0,2284367
15,090
537,2
537,9
104,15
101,96
0,171
0,174
34
0,2310852
15,117
537,3
537,9
103,42
101,46
0,173
0,173
35
0,2315213
14,873
537,3
538,0
103,37
103,37
0,171
0,173
36
0,2277701
15,087
537,3
537,9
103,77
101,44
0,171
0,173
37
0,2310852
15,087
537,2
538,0
101,34
102,16
0,171
0,173
38
0,2310854
15,013
537,2
537,9
104,35
102,18
0,171
0,173
39
0,2299849
15,114
537,2
538,0
101,17
102,04
0,171
0,173
40
0,2315231
15,085
537,2
538,0
101,63
102,42
0,169
0,174
41
0,2310847
15,111
537,2
538,0
101,33
102,24
0,169
0,174
42
0,2315227
15,255
537,3
538,0
99,96
101,35
0,169
0,174
43
0,2337037
15,015
537,4
538,1
104,41
102,37
0,171
0,174
44
0,2299867
15,142
537,5
538,1
101,86
101,45
0,171
0,173
45
0,2319614
15,215
537,5
538,2
102,44
101,17
0,171
0,173
46
0,2330514
15,108
537,5
538,2
100,94
101,75
0,170
0,173
47
0,2315231
15,111
537,5
538,2
103,96
101,82
0,171
0,173
48
0,2315231
15,177
537,5
538,2
102,98
101,19
0,173
0,173
49
0,2326163
15,173
537,5
538,2
101,92
101,80
0,172
0,174
50
0,2326166
14,893
537,5
538,2
103,98
103,57
0,171
0,174
51
0,2284374
15,120
537,4
538,2
101,39
101,34
0,170
0,174
52
0,2319615
15,079
537,4
538,2
103,29
101,61
0,171
0,173
53
0,2313853
Proportional Rates
Particulates Calculations
Page 1 of 4
DATA 2018-01-18 EPA PI 20162 RUN 4 CAT 3 MODEL GM 60
15,009
537,4
538,2
103,31
102,28
0,172
0,173
54
0,2304257
15,216
537,4
538,2
102,10
100,51
0,172
0,173
55
0,2337039
15,105
537,5
538,2
101,17
101,87
0,171
0,174
56
0,231959
15,043
537,5
538,2
101,25
101,80
0,169
0,174
57
0,2310855
15,040
537,6
538,3
101,77
102,34
0,169
0,174
58
0,2310994
15,093
537,5
538,3
103,15
100,98
0,171
0,174
59
0,2319615
15,201
537,5
538,3
99,83
100,35
0,171
0,173
60
0,2337269
15,198
537,4
538,2
102,00
100,38
0,170
0,173
61
0,2337037
15,051
537,4
538,2
103,16
101,37
0,172
0,173
62
0,231523
15,116
537,4
538,2
102,03
100,61
0,172
0,173
63
0,2326164
15,014
537,3
538,1
101,31
101,45
0,171
0,173
64
0,2310851
15,137
537,3
538,1
100,08
101,09
0,169
0,174
65
0,2330512
15,199
537,3
538,1
102,00
100,27
0,171
0,174
66
0,2341372
15,003
537,3
538,1
102,54
101,20
0,172
0,173
67
0,231085
15,247
537,4
538,1
101,63
100,07
0,172
0,173
68
0,2347871
15,130
537,4
538,1
102,40
100,90
0,173
0,174
69
0,2330513
15,054
537,4
538,2
102,89
100,97
0,173
0,174
70
0,2319607
15,122
537,4
538,2
102,48
100,89
0,173
0,174
71
0,2330514
15,183
537,4
538,1
99,67
100,42
0,171
0,174
72
0,2341369
15,180
537,4
538,1
101,73
100,10
0,171
0,174
73
0,2341372
15,177
537,4
538,1
101,12
100,58
0,172
0,174
74
0,2341368
14,977
537,4
538,1
102,52
101,87
0,172
0,174
75
0,2310847
15,143
537,4
538,1
101,99
100,19
0,172
0,174
76
0,233704
15,167
537,3
538,1
101,37
99,99
0,173
0,173
77
0,2341363
15,164
537,3
538,1
101,65
99,86
0,172
0,173
78
0,2341371
15,094
537,4
538,1
101,57
101,01
0,172
0,174
79
0,2330509
15,068
537,4
538,2
100,01
100,36
0,170
0,174
80
0,2326163
14,989
537,5
538,2
100,50
101,03
0,169
0,173
81
0,2315229
15,150
537,5
538,2
99,26
99,62
0,169
0,173
82
0,2341367
15,077
537,4
538,2
99,78
100,45
0,169
0,173
83
0,233051
15,185
537,4
538,1
99,54
99,04
0,169
0,173
84
0,2347864
15,138
537,3
538,1
101,45
99,84
0,171
0,173
85
0,2341374
15,232
537,3
538,0
98,67
99,13
0,171
0,173
86
0,2356488
15,030
537,2
538,0
101,34
100,68
0,170
0,174
87
0,2326167
15,094
537,2
537,9
99,16
99,69
0,170
0,174
88
0,2337044
15,120
537,1
537,9
101,78
100,12
0,171
0,174
89
0,2341375
15,218
537,1
537,9
98,58
99,08
0,171
0,174
90
0,235649
15,159
537,1
537,8
99,73
99,65
0,170
0,174
91
0,2347859
15,018
537,1
537,9
99,61
100,09
0,170
0,173
92
0,2326173
14,978
537,2
537,9
100,16
100,77
0,169
0,173
93
0,2319996
15,015
537,2
537,9
102,20
100,48
0,171
0,174
94
0,232617
15,008
537,1
537,8
99,85
99,91
0,171
0,173
95
0,232617
15,002
537,0
537,7
100,18
99,92
0,170
0,173
96
0,2326062
15,196
536,9
537,7
98,13
98,71
0,169
0,173
97
0,2356482
15,187
536,9
537,7
98,07
99,03
0,169
0,173
98
0,2356488
15,088
536,8
537,6
98,98
99,49
0,169
0,174
99
0,2341372
15,085
536,8
537,6
100,88
100,17
0,171
0,174
100
0,2341376
15,220
536,7
537,5
98,57
98,80
0,171
0,174
101
0,2362936
15,184
536,7
537,5
100,49
99,33
0,171
0,174
102
0,2356485
15,089
536,7
537,5
99,77
100,02
0,172
0,174
103
0,2341369
15,251
536,7
537,5
100,23
98,83
0,172
0,174
104
0,236722
15,219
536,7
537,5
100,55
99,27
0,173
0,175
105
0,2362938
15,176
536,7
537,5
98,04
98,63
0,171
0,174
106
0,235648
15,214
536,7
537,5
97,81
98,30
0,169
0,173
107
0,236294
15,278
536,7
537,4
99,74
98,39
0,171
0,174
108
0,2373642
15,167
536,6
537,4
100,15
99,06
0,173
0,174
109
0,2356485
15,207
536,5
537,3
98,41
98,36
0,171
0,174
110
0,2362943
15,162
536,5
537,2
98,63
98,95
0,170
0,174
111
0,2356485
14,821
536,4
537,2
100,55
100,91
0,170
0,174
112
0,2304255
15,164
536,4
537,2
99,93
98,74
0,171
0,174
113
0,2356485
15,236
536,5
537,2
98,18
98,21
0,171
0,173
114
0,2367221
Particulates Calculations
Page 2 of 4
DATA 2018-01-18 EPA PI 20162 RUN 4 CAT 3 MODEL GM 60
15,107
536,5
537,2
98,56
99,06
0,169
0,173
115
0,2347857
15,162
536,6
537,3
98,96
98,62
0,170
0,173
116
0,2356485
15,035
536,6
537,3
99,07
99,60
0,170
0,174
117
0,233726
14,964
536,5
537,2
101,61
100,58
0,171
0,174
118
0,2326167
15,194
536,4
537,2
99,74
98,61
0,172
0,174
119
0,2362936
15,096
536,3
537,1
100,77
99,33
0,173
0,174
120
0,234786
15,191
536,2
537,0
98,04
98,29
0,171
0,174
121
0,2362941
15,186
536,2
537,0
97,94
97,86
0,169
0,173
122
0,2362895
15,194
536,2
537,0
98,30
98,52
0,170
0,173
123
0,2362936
15,155
536,2
537,0
100,40
98,96
0,171
0,174
124
0,2356481
15,094
536,2
537,0
98,45
98,75
0,171
0,174
125
0,2347857
15,151
536,3
537,0
98,11
98,41
0,169
0,173
126
0,2356865
15,149
536,2
537,0
100,65
99,15
0,171
0,174
127
0,2356487
15,088
536,2
537,0
98,70
98,95
0,171
0,174
128
0,2347856
15,049
536,1
536,9
99,28
99,46
0,170
0,174
129
0,2341373
15,210
536,1
536,9
97,53
97,98
0,169
0,174
130
0,2367223
15,086
536,0
536,8
98,43
98,91
0,169
0,173
131
0,2347872
15,246
536,0
536,8
97,62
98,05
0,169
0,174
132
0,2373644
15,215
536,0
536,8
99,50
98,41
0,171
0,174
133
0,2367218
15,095
536,1
536,8
100,98
99,45
0,173
0,174
134
0,2347859
15,092
536,1
536,9
98,87
98,80
0,172
0,174
135
0,2347857
15,182
536,2
536,9
98,06
98,36
0,170
0,173
136
0,236294
15,210
536,2
536,9
99,57
98,60
0,171
0,174
137
0,2367219
15,178
536,2
536,9
100,40
98,92
0,173
0,174
138
0,2362935
15,136
536,1
536,9
100,33
98,93
0,173
0,174
139
0,235648
15,135
536,1
536,8
100,71
99,11
0,173
0,174
140
0,2356481
15,203
536,0
536,8
97,80
98,30
0,172
0,174
141
0,2367219
15,133
536,0
536,7
100,21
99,04
0,171
0,174
142
0,2356483
14,941
536,0
536,7
101,59
100,50
0,173
0,175
143
0,2326158
15,178
535,9
536,7
98,30
98,48
0,171
0,174
144
0,2362937
15,138
536,0
536,7
98,19
98,68
0,170
0,174
145
0,2356482
15,177
536,0
536,7
99,60
98,32
0,171
0,174
146
0,2362934
15,179
536,0
536,7
97,90
98,19
0,171
0,173
147
0,2362933
15,247
536,0
536,7
97,55
97,67
0,169
0,173
148
0,2373639
15,172
536,0
536,7
98,40
98,28
0,170
0,173
149
0,2362935
15,133
536,0
536,7
100,24
99,08
0,172
0,174
150
0,2356478
15,267
535,9
536,7
98,55
97,55
0,172
0,174
151
0,2377913
15,129
535,9
536,6
98,61
98,84
0,171
0,174
152
0,2356477
15,074
535,9
536,6
98,55
98,66
0,170
0,174
153
0,2347848
15,039
535,9
536,6
101,25
99,54
0,171
0,174
154
0,2341364
15,043
536,0
536,7
99,44
99,38
0,172
0,174
155
0,2341361
15,094
536,0
536,7
98,62
98,64
0,170
0,173
156
0,2349507
15,136
536,0
536,7
98,41
98,42
0,170
0,173
157
0,2356481
15,079
536,0
536,7
101,13
99,39
0,172
0,174
158
0,2347857
15,006
536,0
536,7
99,24
99,07
0,172
0,174
159
0,2337032
15,075
536,0
536,7
99,07
99,25
0,170
0,174
160
0,2347849
15,171
535,9
536,6
100,25
98,85
0,172
0,174
161
0,2362936
15,072
535,9
536,6
98,96
98,87
0,172
0,174
162
0,2347851
15,170
535,8
536,6
100,26
98,78
0,172
0,174
163
0,236293
14,978
535,8
536,6
100,83
99,47
0,173
0,174
164
0,2333434
15,179
535,9
536,6
97,64
98,48
0,171
0,174
165
0,2362932
15,142
535,9
536,6
100,63
99,14
0,171
0,174
166
0,2356479
15,013
536,0
536,6
99,65
99,36
0,172
0,174
167
0,2337033
14,966
536,0
536,7
99,20
99,69
0,170
0,174
168
0,2330509
15,034
536,0
536,7
98,53
99,27
0,169
0,174
169
0,2341372
15,053
536,0
536,7
100,93
99,43
0,171
0,174
170
0,2344433
15,200
536,0
536,7
99,67
98,85
0,173
0,175
171
0,236722
15,128
535,9
536,6
97,88
98,48
0,171
0,174
172
0,2356485
15,127
535,9
536,6
98,60
98,81
0,170
0,174
173
0,2356483
15,164
535,8
536,6
98,54
98,69
0,170
0,174
174
0,2362939
15,190
535,8
536,5
98,17
97,70
0,170
0,174
175
0,2367275
Particulates Calculations
Page 3 of 4
DATA 2018-01-18 EPA PI 20162 RUN 4 CAT 3 MODEL GM 60
14,964
535,7
536,5
101,63
100,20
0,172
0,174
176
0,2330511
15,034
535,8
536,5
101,13
99,72
0,173
0,175
177
0,234137
15,127
535,8
536,5
98,07
98,70
0,171
0,174
178
0,2356481
15,192
535,8
536,5
98,33
98,53
0,170
0,174
179
0,2367218
15,164
535,8
536,5
100,34
98,64
0,172
0,174
180
0,236293
15,187
535,8
536,5
100,29
98,22
0,174
0,174
181
0,236722
15,019
535,7
536,4
101,18
99,45
0,174
0,174
182
0,2341368
14,948
535,7
536,4
100,57
100,41
0,173
0,175
183
0,2330511
15,183
535,7
536,4
97,97
97,99
0,171
0,174
184
0,2367217
15,009
535,6
536,4
98,72
99,32
0,170
0,174
185
0,234088
15,184
535,6
536,4
98,80
97,65
0,170
0,173
186
0,2367218
15,187
535,7
536,4
97,72
97,98
0,170
0,173
187
0,236722
Particulates Calculations
Page 4 of 4
DATA 2018-01-22 EPA PI 20162 RUN 5 CAT 4 MODEL GM 60
Average
Average
Average
Average
15,04
Inlet +
Inlet +
0,231
Outlet
Outlet
Average
Average
#1
#2
Tunnel
Temp.
Temp.
101,45
100,99
System 1
System 2
SQRT
Velocity
Meter 1
Meter 2
Vol.Std.
Vol.Std.
Delta-P
PR1
PR2
Time
Ft/Sec
Deg. R
Deg. R
%%
(ft3)
(ft3)
min
(in H2O)2
15,463
535,6
535,9
0,171
0,176
0
0,2284367
15,164
535,4
535,9
102,20
101,73
0,171
0,175
1
0,2315234
15,296
535,3
535,9
102,87
100,38
0,173
0,174
2
0,2341377
15,117
535,2
535,9
102,06
101,70
0,173
0,174
3
0,2312119
15,165
535,2
535,9
101,86
101,53
0,172
0,174
4
0,2319617
15,111
535,2
535,9
104,34
101,66
0,173
0,174
5
0,2310856
15,142
535,2
535,9
104,54
101,71
0,175
0,174
6
0,2315239
15,115
535,2
536,0
103,03
101,90
0,174
0,174
7
0,2310863
15,152
535,2
535,9
104,61
101,47
0,174
0,174
8
0,2315237
15,018
535,1
535,9
103,68
103,08
0,174
0,174
9
0,2293239
15,266
535,1
535,9
101,59
101,42
0,172
0,175
10
0,2330522
15,186
535,1
536,0
104,43
101,83
0,173
0,174
11
0,231524
14,916
535,2
536,0
104,82
103,91
0,174
0,174
12
0,2273246
15,122
535,3
536,1
104,50
102,31
0,173
0,174
13
0,2304264
15,167
535,4
536,2
103,44
102,28
0,174
0,174
14
0,2310865
15,097
535,4
536,2
102,88
103,23
0,172
0,175
15
0,2299868
15,001
535,4
536,3
105,64
103,13
0,173
0,174
16
0,2284382
15,131
535,4
536,3
104,60
102,25
0,174
0,174
17
0,2304267
15,102
535,3
536,3
105,09
102,51
0,175
0,174
18
0,229987
15,209
535,4
536,3
101,76
102,42
0,173
0,174
19
0,2315244
15,217
535,5
536,4
101,87
102,81
0,170
0,175
20
0,2315246
15,069
535,7
536,5
102,92
103,20
0,170
0,175
21
0,2293244
15,146
535,7
536,6
104,66
102,24
0,172
0,174
22
0,2304271
14,936
535,8
536,7
105,79
103,51
0,174
0,173
23
0,2273211
15,178
535,8
536,7
104,07
101,91
0,174
0,173
24
0,2310869
15,203
535,9
536,8
104,06
101,68
0,174
0,174
25
0,2315247
15,058
535,9
536,8
102,44
103,18
0,172
0,174
26
0,2293236
15,137
536,0
536,9
104,29
102,36
0,172
0,174
27
0,2304274
15,012
536,1
536,9
105,03
102,91
0,174
0,173
28
0,2284383
14,968
536,2
537,0
104,03
103,65
0,172
0,174
29
0,2277711
15,012
536,3
537,1
105,02
103,28
0,172
0,174
30
0,2284645
15,105
536,3
537,2
102,36
102,69
0,172
0,174
31
0,2299871
15,129
536,3
537,2
102,00
102,72
0,170
0,174
32
0,2304272
15,097
536,4
537,3
102,80
102,68
0,171
0,174
33
0,2299877
15,123
536,4
537,3
103,09
101,75
0,171
0,174
34
0,2304277
15,049
536,5
537,4
102,27
103,15
0,171
0,174
35
0,2293247
15,190
536,5
537,4
103,32
101,40
0,171
0,174
36
0,2315254
15,053
536,6
537,5
104,58
102,62
0,173
0,173
37
0,229402
15,084
536,7
537,6
104,29
102,33
0,174
0,174
38
0,2299889
15,110
536,8
537,6
101,69
102,80
0,172
0,174
39
0,230428
15,075
536,9
537,7
101,70
101,97
0,170
0,174
40
0,2299884
15,026
536,8
537,7
102,47
102,54
0,170
0,173
41
0,2293256
14,962
536,9
537,7
102,47
103,55
0,170
0,174
42
0,2284399
15,163
536,9
537,7
102,78
101,90
0,171
0,175
43
0,2315263
15,131
536,8
537,7
100,90
101,95
0,171
0,174
44
0,2310883
15,190
536,9
537,7
100,58
101,72
0,169
0,174
45
0,2319653
15,137
537,0
537,8
103,65
101,98
0,171
0,174
46
0,2310882
15,132
537,1
537,9
100,76
101,87
0,171
0,174
47
0,2310843
14,881
537,2
538,0
103,36
104,02
0,170
0,174
48
0,2273271
14,997
537,1
538,0
103,38
101,89
0,171
0,174
49
0,229326
15,132
537,2
538,0
101,55
101,82
0,172
0,174
50
0,2315266
15,029
537,2
538,0
101,06
102,29
0,170
0,174
51
0,2299887
15,120
537,1
538,0
102,93
101,05
0,171
0,174
52
0,2315269
15,015
537,1
538,0
103,50
101,79
0,173
0,174
53
0,2299884
Proportional Rates
Particulates Calculations
Page 1 of 3
DATA 2018-01-22 EPA PI 20162 RUN 5 CAT 4 MODEL GM 60
15,140
537,1
538,0
102,45
101,22
0,173
0,174
54
0,2319647
15,185
537,2
538,0
100,12
101,16
0,171
0,174
55
0,23262
15,035
537,3
538,1
101,00
101,93
0,169
0,174
56
0,230429
15,130
537,3
538,1
102,39
100,59
0,171
0,174
57
0,2319652
15,019
537,3
538,1
103,19
101,49
0,173
0,173
58
0,2304291
15,083
537,3
538,2
99,89
101,27
0,171
0,174
59
0,2315274
14,726
537,3
538,2
102,22
103,23
0,169
0,174
60
0,2262095
15,039
537,3
538,1
100,62
100,74
0,169
0,173
61
0,231089
15,038
537,3
538,1
100,22
101,30
0,169
0,174
62
0,2311919
15,132
537,3
538,1
100,13
100,18
0,170
0,174
63
0,2326206
15,063
537,3
538,2
100,52
101,51
0,170
0,174
64
0,2315272
14,963
537,4
538,2
103,12
101,09
0,172
0,174
65
0,2300374
15,054
537,5
538,2
102,02
100,61
0,173
0,173
66
0,2315274
15,077
537,5
538,3
99,89
100,56
0,171
0,174
67
0,2319655
14,973
537,5
538,3
100,50
101,62
0,169
0,174
68
0,2304301
14,934
537,5
538,3
102,85
101,58
0,171
0,174
69
0,2299901
14,710
537,5
538,3
104,29
102,82
0,173
0,174
70
0,2266581
15,049
537,4
538,2
101,25
100,31
0,172
0,174
71
0,2319657
14,941
537,3
538,2
100,01
101,11
0,170
0,174
72
0,2304297
15,111
537,3
538,2
99,42
99,67
0,169
0,174
73
0,2330561
14,942
537,4
538,2
100,02
101,14
0,169
0,174
74
0,2304293
15,007
537,4
538,2
101,30
100,17
0,170
0,174
75
0,2315277
14,931
537,4
538,3
102,57
100,93
0,173
0,173
76
0,2304298
14,851
537,5
538,3
100,64
101,71
0,171
0,174
77
0,2293272
15,056
537,4
538,3
100,47
100,33
0,170
0,174
78
0,2325542
14,953
537,4
538,2
100,29
100,35
0,171
0,174
79
0,2310896
15,003
537,3
538,2
101,59
100,04
0,172
0,174
80
0,231966
15,109
537,3
538,2
98,97
99,58
0,171
0,174
81
0,2337083
14,892
537,3
538,1
101,99
101,34
0,171
0,175
82
0,2304302
15,101
537,3
538,1
98,64
98,97
0,171
0,174
83
0,2337088
14,964
537,3
538,1
102,02
100,54
0,172
0,174
84
0,2315268
15,097
537,3
538,1
98,53
99,23
0,171
0,174
85
0,2337084
14,955
537,3
538,2
99,26
100,22
0,169
0,174
86
0,2315284
14,978
537,3
538,2
101,49
100,32
0,171
0,174
87
0,2319657
14,703
537,3
538,2
101,01
101,68
0,171
0,174
88
0,2277732
15,039
537,3
538,1
99,43
98,97
0,170
0,173
89
0,2330561
14,696
537,2
538,1
103,36
101,96
0,172
0,174
90
0,2277982
15,033
537,2
538,0
98,79
99,27
0,171
0,174
91
0,2330561
15,030
537,1
538,0
100,88
99,26
0,171
0,174
92
0,2330562
15,198
537,1
537,9
98,06
97,99
0,172
0,173
93
0,2356534
15,034
537,1
537,9
98,64
99,51
0,170
0,174
94
0,2330558
14,962
537,1
537,9
101,50
99,80
0,171
0,174
95
0,2319667
14,928
537,1
537,9
100,66
100,13
0,173
0,174
96
0,2315271
15,067
537,1
537,9
98,66
98,97
0,171
0,174
97
0,233706
15,024
537,1
537,9
98,55
98,84
0,170
0,173
98
0,233056
15,020
537,0
537,9
98,85
99,69
0,170
0,174
99
0,2330548
15,017
537,0
537,9
99,24
99,29
0,170
0,174
100
0,2330557
15,055
536,9
537,8
98,90
98,93
0,170
0,174
101
0,2337057
14,981
536,9
537,8
99,49
99,68
0,171
0,174
102
0,2326209
15,079
536,9
537,8
98,05
98,96
0,170
0,174
103
0,2341429
15,052
536,9
537,7
100,87
99,60
0,172
0,175
104
0,2337083
15,122
536,9
537,7
97,79
98,44
0,172
0,174
105
0,2347909
14,911
536,9
537,7
101,11
100,32
0,171
0,174
106
0,2315278
14,936
536,9
537,7
98,88
99,84
0,171
0,174
107
0,2319655
14,930
536,8
537,7
101,21
100,15
0,171
0,174
108
0,2319657
14,975
536,8
537,7
101,05
99,85
0,173
0,175
109
0,2326206
14,994
536,7
537,6
99,45
99,09
0,172
0,174
110
0,2330556
15,033
536,7
537,6
98,32
99,00
0,170
0,174
111
0,2337081
14,986
536,6
537,6
100,63
99,51
0,171
0,174
112
0,2330553
15,030
536,6
537,5
99,69
98,75
0,173
0,174
113
0,2337081
15,099
536,6
537,5
98,08
98,37
0,171
0,174
114
0,2347902
Particulates Calculations
Page 2 of 3
DATA 2018-01-22 EPA PI 20162 RUN 5 CAT 4 MODEL GM 60
14,820
536,7
537,5
100,84
100,27
0,171
0,174
115
0,23043
14,890
536,7
537,6
101,42
100,34
0,172
0,174
116
0,231527
14,985
536,7
537,6
98,92
99,32
0,172
0,175
117
0,233055
15,052
536,6
537,5
98,23
98,62
0,170
0,174
118
0,2341407
15,023
536,6
537,5
98,06
98,69
0,170
0,174
119
0,2337076
14,952
536,6
537,5
100,78
99,61
0,171
0,174
120
0,23262
14,807
536,5
537,4
99,65
100,08
0,171
0,174
121
0,2304294
15,018
536,5
537,4
97,93
98,46
0,169
0,174
122
0,2337076
14,976
536,5
537,4
99,88
99,47
0,171
0,174
123
0,233055
14,949
536,5
537,4
99,60
99,25
0,172
0,174
124
0,2326207
14,978
536,5
537,4
99,50
99,36
0,171
0,174
125
0,2330553
14,979
536,5
537,4
98,50
99,03
0,170
0,174
126
0,2330546
14,876
536,5
537,4
101,37
100,26
0,172
0,174
127
0,2315266
15,015
536,5
537,4
98,92
98,76
0,172
0,174
128
0,2337075
15,014
536,4
537,3
100,42
99,39
0,172
0,174
129
0,2337083
15,038
536,4
537,3
100,40
99,00
0,174
0,175
130
0,2341407
Particulates Calculations
Page 3 of 3
St-jean-sur-Richelieu, February 6th 2018
Client: Hearthstone
Project: PI-20162
Model: GM-60
Page 19 of 28
M_rap_EPAwoodstove V1 – 2015 july 30th
APPENDIX 5: Participants
Danick Power ing.
v-p operation
Services Polytests inc.
450.741.3636
www.polytests.com
Maxime Martin
Technicien
Services Polytests inc.
450.741.3636
www.polytests.com
Dave Bryant
Dave Bryant
Dave Bryant
Dave Bryant
Hearthstone
St-jean-sur-Richelieu, February 6th 2018
Client: Hearthstone
Project: PI-20162
Model: GM-60
Page 21 of 28
M_rap_EPAwoodstove V1 – 2015 july 30th
APPENDIX 7: Operator’s manual
Green Mountain 60 (Model 8660)
Manual: 6400-41408
R: 02/7/2018
Green Mountain 60
(Model 8660)
Woodstove
OWNER'S MANUAL
Installation And
Operating Instructions
SAVE THIS OWNER’S MANUAL
FOR FUTURE REFERENCE
PLEASE READ THIS ENTIRE OWNER’S MANUAL BEFORE YOU INSTALL AND USE YOUR
NEW GREEN MOUNTAIN 60 WOOD STOVE.
If this room heater is not properly installed, a house fire may result.
To reduce the risk of fire, follow the installation instructions.
Failure to follow these instructions can result in property damage, bodily injury, or even death.
Conforms to UL Std. 1482
Certified to ULC Std. S627
CONTACT LOCAL AUTHORITIES WITH JURISDICTION (BUILDING DEPARTMENT or FIRE
OFFICIALS), ABOUT PERMITS REQUIRED, RESTRICTIONS AND INSTALLATION
INSPECTION IN YOUR AREA.
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
1
NOTES ON STOVE OPERATION AND EFFICIENCY
Rating:
You have purchased a Hearthstone Green Mountain 60 tested to EPA Method 28R 40 CFR Part 60 where applicable. This
stove is certified to comply with the U.S. Environmental Protection Agency 2020 particulate emissions standard using crib
wood. It is certified at 0.6 gr/hr. emission rate and under specific test conditions has been shown to deliver heat at rates
ranging from 12,600 to 33,600 Btu (output).
This wood heater has a manufacturer-set minimum allowable low burn rate that must not be altered. It is against federal
regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in
this manual.
Please refer to the Warranty section of this manual for registration instructions. In case of warranty claims, please contact
the point of original sale or the nearest authorized Hearthstone dealer. Our dealer network processes all warranty claims.
Authorized Hearthstone dealers can be located at www.hearthstonestoves.com.
This heater is designed to burn natural wood only. Higher efficiencies and lower emissions generally result when burning
air-dried seasoned hardwoods, as compared to softwoods or to green or freshly cut hardwoods. DO NOT BURN: Garbage,
lawn clippings, material containing rubber (including tires), materials containing plastic, waste petroleum products paints or
paint thinners, asphalt products, materials containing asbestos, construction or demolition debris, railroad ties, pressure
treated wood, manure or animal remains, salt water driftwood or other previously salt water saturated materials, unseasoned
wood, paper products, cardboard, plywood or particleboard. This prohibition against burning these materials does not
prohibit the use of fire starters made from paper, cardboard, sawdust, wax and similar substances for the purpose of starting
a fire in an affected wood heater. Burning these materials may result in a release toxic fumes or render the heater ineffective
and cause smoke.
Following the maintenance guidelines set forth in this manual will help insure the efficient use of your wood heater and
minimize visible emissions. Having your stove inspected by a trained professional on a regular basis will greatly increase the
potential for recognizing potential impacts to efficiency.
Proper draft is important to the efficient operation of your heater. Refer to the Normal Operation section of this manual for
information regarding adequate draft. Both excessive and sub-minimum draft can affect the efficiency of your wood heater.
Excessive draft can lead to over-consumption of fuel, lower overall heating capacity of the stove and potential over firing.
Low draft can result in inefficient burns, low heat output, expulsion of smoke into the living area when stove doors are
opened and an increased potential for build-up of flammable materials in the flue.
Efficiency:
Efficiency was measured and weighted using EPA Method 28R and CSA B415-10 methodology. A weighted average was
used to calculate the overall efficiency across all of the 4 burn rate categories using the higher heating value (HHV). The
weighted average efficiency is 79% (HHV).
To maximize the efficiency of your wood stove make sure it is sized properly for the space you plan to heat. An oversized
stove will often be forced to burn at a lower and dirtier burn rate. Consult with your dealer for sizing and correctly placing the
stove in your home. An incorrectly placed stove can greatly reduce efficiency. Maximizing the efficiency of your stove will
heat your house quickly, burn cleaner and use less wood.
Refer to the Choosing Firewood section of this manual for appropriate fuel selection. Seasoned firewood is typically at or
near 20% moisture content. This can be measured with any number of hand-held moisture meters available through your
local hearth shop. Follow instructions included in the meter you purchase to measure fuel wood moisture content. Burn only
dry, seasoned wood as using wet wood will greatly reduce your efficiency.
CO Emissions:
The Green Mountain 60 has the following CO emission rates by burn level: Category 1 (low) –9.0 g/hr., Category 2 (med.
low) – 21.0 g/hr., Category 3 (med. high) – 33.0 g/hr. and Category 4 – 51.6 g/hr. Wet wood or unapproved fuel described
above can greatly affect the emissions of a wood burning stove.
Smoke/Fire/CO Detectors:
It is highly recommended that smoke and CO detectors be installed throughout the heated space when a wood burning
heater is installed. Be certain to install these devices not only in the area where the wood appliance is located, but also in
bedrooms, hallways leading to other areas of the house and all common areas of the heated space. Check the batteries in
these devices and assure operation by performing whatever test operations are recommended by the manufacturer.
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
2
TABLE OF CONTENTS
INTRODUCTION ..................................................................................................................... 3
CODES ................................................................................................................................................................... 4
SAFETY INFORMATION ............................................................................................................................................ 4
PERIODIC CHECKLIST ............................................................................................................................................. 5
EMERGENCY PROCEDURES .................................................................................................................................... 5
SPECIFICATIONS .................................................................................................................. 6
INSTALLATION ...................................................................................................................... 7
UNPACKING ............................................................................................................................................................ 7
PACK LIST .............................................................................................................................................................. 7
INSTALLING YOUR STOVE........................................................................................................................................ 7
HEARTH REQUIREMENTS & FLOOR PROTECTION...................................................................................................... 8
COMBUSTIBLE SURFACE REQUIRED CLEARANCES ................................................................................................... 9
CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES FROM COMBUSTIBLE WALLS .................................................... 11
OUTSIDE AIR SUPPLY ........................................................................................................................................... 12
VENTING COMPONENTS & CONFIGURATION REQUIREMENTS ................................................................................... 13
INSTALLING IN A MOBILE HOME ............................................................................................................................. 17
OPERATION ......................................................................................................................... 18
CONTROLS AND FEATURES ................................................................................................................................... 18
BUILDING A FIRE .................................................................................................................................................. 20
BREAKING IN YOUR WOOD STOVE ........................................................................................................................ 20
NORMAL OPERATION ............................................................................................................................................ 21
CATALYTIC COMBUSTOR OPERATION .................................................................................................................... 22
MAINTENANCE .................................................................................................................... 24
CATALYTIC COMBUSTOR INSPECTION AND REPLACEMENT PROCEDURES ................................................................ 24
INSPECTING THE CATALYSTS ................................................................................................................................. 24
REPLACING THE CATALYSTS .................................................................................................................................. 25
REPLACING THE BAFFLE ........................................................................................................................................ 25
REPLACING THE REFRACTORY STONE AND SECONDARY RISER ASSEMBLY ................................................................ 26
GLASS REPLACEMENT PROCEDURES .................................................................................................................... 27
CREOSOTE FORMATION & REMOVAL ..................................................................................................................... 28
GASKETS ............................................................................................................................................................. 28
GLASS ................................................................................................................................................................. 28
TROUBLESHOOTING .......................................................................................................... 29
TROUBLESHOOTING GUIDE ................................................................................................................................... 30
REPLACEMENT PARTS & OPTIONAL ACCESSORIES ................................................................................................. 32
SAFETY LABEL ................................................................................................................... 33
WARRANTY .......................................................................................................................... 34
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
3
INTRODUCTION
Thank you for purchasing a Green Mountain 60
woodstove from Hearthstone Quality Home Heating
Products.
This
stove
will
provide
years
of
comfortable heat. This stove combines the warmth
and comfort of soapstone and cast iron with the
efficiency of advanced catalytic technology. The
Green Mountain 60 blends modern technology with
the unique beauty and qualities of cast iron. We trust
that you will appreciate the quality of this
handcrafted product.
Your Green Mountain 60 woodstove burns very
efficiently, and produces a large amount of heat.
However, you should not consider your Green
Mountain 60 the primary heat source for your home.
The Green Mountain 60’s large glass window allows
you to enjoy the fire from a variety of locations in the
room.
Please read this manual in its entirety. Its purpose is
to familiarize you with your stove's safe installation,
proper break-in, operation and maintenance. It
contains extremely important information so keep it
handy and refer to it often.
A qualified heating technician may need this owner’s
manual as a reference when installing this stove in
your home. There are national, state, and local
building codes that direct the technician on how to
install your stove. These codes stipulate the
dimension of stovepipe and clearances to walls,
ceilings, hearth, and other combustible surfaces.
The codes exist to reduce the risk of fire. Failure to
follow these instructions can result in fire, property
damage, bodily injury, and even death.
Install the stove in a safe, open area, away from
traffic flow, doors, and hallways. If possible, try to
install the stove near an existing chimney and
chimney connector. It is extremely important to
install this stove with the proper clearance from
combustible surfaces. You can purchase specific
connector pipe and special wall coverings as
specified by this manual and the NFPA 211 code to
protect combustible surfaces. As a general rule,
keep furniture, drapes, curtains, wood, paper, and
other combustibles at least 36 inches (92 cm) away
from the stove. Never install the stove in or near a
storage location for gasoline, kerosene, charcoal
lighter fluid or any other flammable liquids.
Install the stove in your central living area to allow
heat to radiate naturally to distant rooms. Do not
install your stove in a poorly insulated area. This is
inefficient and would likely result in higher fuel
usage.
•
SAFETY NOTICE:
AN IMPROPERLY INSTALLED STOVE CAN
RESULT IN A HOUSE FIRE. FOR YOUR SAFETY,
CAREFULLY FOLLOW THE INSTALLATION
DIRECTIONS. CONTACT LOCAL BUILDING OR
FIRE OFFICIALS ABOUT RESTRICTIONS AND
INSTALLATION INSPECTION IN YOUR AREA.
The safety of your stove will depend on many
factors, some of which include: distance to
combustible objects, correct venting, and adequate
chimney maintenance. Should you have any
questions, do not hesitate to contact your dealer for
additional information.
Contact your dealer for any necessary warranty
service.
This Green Mountain 60 Model 8660 stove is
warranted by:
Hearthstone Quality Home Heating Products, Inc®
317 Stafford Ave.
Morrisville, Vermont 05661, USA
www.Hearthstonestoves.com
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
4
CODES
When
you
install
your
Green
Mountain
60
woodstove, it is imperative that you adhere to all
Federal and local codes. Obtain these codes from
either of the following sources:
American National Standards Institute, Inc. (ANSI)
1430 Broadway
New York, NY 10018
www.ansi.org
National Fire Protection Association, Inc. (NFPA)
Battery March Park
Quincy, MA 02269
www.nfpa.org
If you are installing your Green Mountain 60 in a
mobile or manufactured home, follow the guidelines
described in the Manufactured Home Construction
and Safety Standard, Title 24 CFR, Part 3280
(United States).
SAFETY INFORMATION
Read and understand this Owner's Manual
thoroughly before installing and using this
stove.
Make sure to install your stove:
•
According to the manufacturer's
recommendations
•
In accordance with all applicable codes
•
With the proper sized chimney
When using your stove, follow these safety
precautions:
•
Never modify this stove in any way.
•
Never burn kiln dried, painted or treated wood in
this stove.
•
DO NOT BURN GARBAGE. Never burn
garbage or trash, colored or glossy paper,
solvents, plywood, artificial logs, cardboard, or
driftwood, in this stove.
•
Never burn coal in this stove.
•
DO NOT BURN FLAMMABLE FLUIDS.
•
DO NOT USE CHEMICALS OR FLUIDS TO
START THE FIRE. Never use gasoline,
kerosene, charcoal
lighter
fluid,
or
other
flammable fluids to start or invigorate the fire.
These fuels will cause dangerous burning
conditions in the stove. Keep all such materials
away from the stove.
•
Never use a wood grate or other device to
elevate the fire.
•
Never allow logs in the firebox to hit the glass
when the door is closed.
•
Never slam the door or use the door to force
wood in to the stove.
•
Never over-fire your stove. (See page 23)
•
Never put articles of clothing or candles on a hot
stove.
•
Never connect the stove to a flue used by
another appliance.
Other safety guidelines:
•
Keep all combustible items such as furniture,
drapes, clothing, and other items, at least 36"
(0.92 m) from the stove (See page 8)
•
Install a smoke detector, preferably in an area
away from your wood stove.
•
Keep a fire extinguisher handy. We recommend
the type rated "A B C."
•
Dispose of ashes properly. (See page 23)
•
Keep children and pets away from the stove
when it is burning; they could be seriously
injured by touching a hot stove.
•
Clean your chimney system as needed. (See
page 28)
•
Outside combustion air may be required if:
1.
This solid-fuel-fired appliance does not
draw steadily, smoke rollout occurs, fuel
burns poorly, or back-drafts occur whether
or not there is combustion present.
2.
Existing fuel-fired equipment in the house,
such as fireplaces or other heating
appliances, smell, do not operate properly,
suffer smoke roll-out when opened, or
back-draft whether or not there is
combustion present.
3.
Opening a window slightly on a calm
(windless) day alleviates any of the above
symptoms.
4.
The house is equipped with a well-sealed
vapor barrier and tight fitting windows
and/or has any powered devices that
exhaust house air.
5.
There is excessive condensation on
windows in the winter.
6.
A ventilation system is installed in the
house.
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
5
If these or other indications suggest that infiltration
air is inadequate, additional combustion air should
be provided from the outdoors. Outside combustion
air can be provided to the appliance by using the
optional outside air kit #96-53400
PERIODIC CHECKLIST
Perform each of these tasks at the specified
intervals.
At the End of Every Week:
•
Empty ashes from the firebox, sooner if the
firebox is full.
At the Beginning of Every Other Month:
•
Depending upon your use of the stove, visually
inspect the chimney connector and chimney for
creosote. (see page 28)
•
Check door seals using the "dollar bill test." -
When the stove is cool, shut the door on a dollar
bill. If the bill pulls out without any resistance,
then your stove’s door is not sealing properly. To
tighten the seal, adjust the door latch
mechanism or change the door gasket. (Refer to
page 28.)
•
Inspect the face of the catalytic combustor for fly
ash and soot. Use a soft-bristled brush to
remove if present. It is recommended to visually
inspect the catalytic combustor at least 3 times
during the heating season, or every 2-3 months.
At the End of Every Season:
•
Dismantle the chimney connector and clean it
thoroughly. Replace any pieces that show signs
of rust or deterioration.
•
Inspect and, if necessary, clean your chimney.
•
Clean out the inside of the stove thoroughly.
•
Check and clean the catalytic combustor, if
necessary
•
Inspect all door gasket material and replace if
worn, frayed, cracked or extremely hard.
EMERGENCY PROCEDURES
If you have a stovepipe or chimney fire, follow these
instructions:
1. If the fire is too threatening, leave the area and
call the fire department immediately! If not,
perform the next three steps.
2. Close the primary air control.
3. Close the stovepipe damper (if present).
4. Close the bypass damper
5. Keep the stove front door closed!
•
WARNING: DO NOT ATTEMPT TO PUT OUT A
STOVEPIPE OR CHIMNEY FIRE BY THROWING
WATER ONTO THE STOVE, STOVEPIPE, OR
CHIMNEY. THE EXTREMELY HIGH
TEMPERATURE OF SUCH FIRES CAN CAUSE
INSTANTANEOUS STEAM AND SERIOUS BODILY
HARM.
Once the chimney fire expires, leave the primary air
control and bypass handle closed and let the fire in
the stove die out completely. Inspect the stove,
stovepipe, and chimney thoroughly for any sign of
damage before firing the stove again. You must
correct any damage before using your stove again.
Establish a routine for the fuel, wood burner and
firing technique. Check daily for creosote build-up
until experience shows how often you need to clean
to be safe. Be aware that the hotter the fire the less
creosote is deposited, and weekly cleaning may be
necessary in mild weather even though monthly
cleaning may be enough in the coldest months.
Contact your local municipal or provincial fire
authority for information on how to handle a chimney
fire. Have a clearly understood plan to handle a
chimney fire.
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
6
SPECIFICATIONS
Maximum Heat Output:
60,000 BTUs per hour of cordwood (based on
independent laboratory test results).
Floor Size of Heated Area:
Up to a maximum of 2,000 square feet. Factors
unique to your home can reduce the square
footage the stove will heat. Home insulation
value, number and efficiency of windows, floor
plan, stove placement, quality of the fuel and
other conditions may limit the heating ability of
the stove.
Firebox Capacity:
2.0 cubic feet.
Maximum Log Length: Up To 18” (45.7cm).
Emissions: 0.9 g/hr.
Burn Time: Up to 24+ hrs. (Heat Life™: Up to 30
hours) Note: The amount and weight of wood
contained per cubic foot of firebox volume can
vary from 10 to 25 lbs. per cubic foot depending
on type of wood, moisture content, packing
density and other factors.
Stove Dimensions:
Height:
31 1/2” (80.0cm)
Width:
26" (66.0cm)
Depth:
21 1/4" (54.0cm)
Weight:
494 lbs. (269 kg)
Connector Size:
6" (152 mm) diameter
Metal Chimney:
6" (152 mm) inside diameter
Masonry Chimney:
6” (152 mm) inside diameter
(round flue), 8” x 8” (203 x 203 mm) (square
flue)
Crate Dimensions:
H-40” W-29” L-36” or
102x74x 92cm
Optional Equipment:
Outside Air Kit
96-53400
Blower Kit
96-57400
Figure 1 – Green Mountain 60 Dimensions
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
7
INSTALLATION
UNPACKING
Hearthstone packages your Green Mountain 60
woodstove with the greatest care so that it ships
safely. Under certain circumstances, however,
damage may occur during transit and handling.
When you receive the Green Mountain 60, carefully
unpack and inspect the stove and all accompanying
parts. Ensure that all parts are included inside the
stove. If any parts are damaged or missing, please
contact
your
authorized
Hearthstone
dealer
immediately.
PACK LIST
Green Mountain 60 Model 8660 Woodstove
Owner’s Manual
The label is attached by a cable to the bottom of the
stove. Take care when lifting the stove not to
damage the label or cable. After final positioning of
the stove, the label may be stored in the holding clip
on the bottom shield of the stove.
Figure 2 - Label Location
INSTALLING YOUR STOVE
Choose a place to install your Green Mountain 60
woodstove. Consider the location of your stove for
optimum heating efficiency. In general, it is better to
place your stove in a main living area, rather than in
a basement or other confined space.
Inspect this location to make sure that the stove and
stovepipes will have the required clearance from
combustible materials that are near the stove.
Combustibles include walls, floor, ceiling, and
chimney chase. You must carefully consider the
clearances to all of these combustibles before
actually connecting your stove.
If the floor is made of combustible material, then a
non-combustible floor protector is required between
the floor and the stove. An example of a non-
combustible floor protector is a hearth constructed
with a continuous layer of tile, brick, slate, glass or
another non-combustible facing. There is no R-value
requirement.
If you use a rear connector pipe, ensure it is listed
with Underwriter’s Laboratories. Check the listing of
your pipe with UL for the correct clearances.
The diagrams in this manual represent typical
installations, but are specific to the Simpson Dura-
Vent DVL brand.
Clearances
to
NFPA
Code
211
Protected
Surfaces
You can reduce the clearances to combustible
surfaces by using any National Fire Protection
Agency (NFPA) approved wall protection system
with additional approval of the regulatory authority
having jurisdiction in your area. Please refer to
NFPA Code 211 for specifications and complete
details. You can obtain this information directly from
the NFPA.
National Fire Protection Agency
Batterymarch Park
Quincy, MA 02269
1-800-344-3555
1-617-770-3000
www.nfpa.org
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
8
HEARTH REQUIREMENTS & FLOOR PROTECTION
Ensure you protect combustible flooring with a covering of noncombustible material. The Green Mountain 60
does not require an insulated hearth pad. The minimum floor protection must be met under the stove and extend
beyond the stove as follows:
The minimum floor protection for US installations is 33 1/4in x 31-1/2in.
The minimum floor protection for installations in Canada is 42in x 43 1/2in.
Figure 3 – Hearth Dimensions
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
9
COMBUSTIBLE SURFACE REQUIRED CLEARANCES
Note: Dimensions shown in the following figures are from the body of the stove unless otherwise indicated.
It is very important to follow minimum clearances for chimney connectors to combustibles such as walls and
ceilings when installing the stove near combustible surfaces.
Figure 4 – Clearance to Combustibles
Parallel
Corner
Corner
Clearances
ABCDEF
Single wall Connector – Inc. Rear Heat Shield
13”-33cm 9”-23cm 14”-36cm
24.5”-63cm 6”-16cm 16.5”-42cm
Single Wall Connector – With Blower Kit Shield
13”-33cm 9”-23cm 14”-36cm
24.5”-63cm 6”-16cm 16.5”-42cm
Double Wall Connector – Inc. Rear Heat Shield
13”-33cm 7”-18cm 12”-32cm
24.5”-64cm 6”-16cm 16.5”-42cm
Double Wall Connector – With Blower Kit Shield
13”-33cm 7”-18cm 12”-32cm
24.5”-64cm 6”-16cm 16.5”-42cm
Alcove W/Single Wall Conn – Inc. Rear Heat Shield 13”-33cm 9”-23cm 14”-36cm
24.5”-63cm 6”-16cm 16.5”-42cm
Alcove W/Single Wall Conn – With Blower Kit Shield 13”-33cm 9”-23cm 14”-36cm
24.5”-63cm 6”-16cm 16.5”-42cm
Alcove W/Dbl Wall Conn – Inc. Rear Heat Shield
13”-33cm 9”-23cm 14”-35cm
24.5”-61cm 6”-16cm 16.5”-42cm
Alcove W/Dbl Wall Conn – With Blower Kit Shield
13”-33cm 9”-23cm 14”-35cm
24.5”-61cm 6”-16cm 16.5”-42cm
Alcove Clearances (inches)
Unprotected Surfaces Protected Surfaces (NFPA-211)
Minimum alcove width
50” – 157.5cm
See NFPA-211
Min. Alcove ceiling from floor with single wall connector 56” – 142.3cm
See NFPA-211
Min. Alcove ceiling from floor with double wall connector 56” – 142.3cm
See NFPA-211
FOR BLOWER KIT, USE KIT #96-57400
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
10
Figure 5 Chimney Connector Clearances
Single Wall Pipe
Double Wall Pipe
Through the wall top flue exit
With Blower Kit
Shield**
Inc. Rear Heat
Shield
With Blower Kit
Shield**
Inc. Rear Heat
Shield
A
9” (23cm)
9” (23cm)
7” (18 cm)
7” (18 cm)
B
14” (36 cm)
14” (36 cm)
12” (32cm)
12” (32cm)
*For double wall pipe clearance to ceiling,
refer to pipe manufacturer specifications.
** FOR BLOWER KIT, USE KIT #96-57400
See Parallel Clearance to Combustibles for
clearances to the sides of the stove.
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
11
CHIMNEY CONNECTOR SYSTEMS AND
CLEARANCES FROM COMBUSTIBLE WALLS
FOR RESIDENTIAL HEATING APPLIANCES
A. Minimum 3.5in thick brick masonry all framed
into combustible wall with a minimum of 12in.
brick separation from clay liner to combustibles.
The fire clay liner shall run from outer surface of
brick wall to, but not beyond, the inner surface
of chimney flue liner and shall be firmly
cemented in place.
B. Solid-insulated, listed factory-built chimney
length of the same inside diameter as the
chimney connector and having 1in. or more of
insulation with a minimum 9in. air space
between the outer wall of the chimney length
and combustibles.
C. Sheet steel chimney connector, minimum 24
gauge in thickness, with a ventilated thimble,
minimum 24 gauge in thickness, having two 1in.
air channels, separated from combustibles by a
minimum of 6in of glass fiber insulation.
Opening shall be covered, and thimble
supported with a sheet steel support, minimum
24 gauge in thickness.
D. Solid insulated, listed factory-built chimney
length with an inside diameter 2in. larger than
the chimney connector and having 1in. or more
of insulation, serving as a pass-through for a
single wall sheet steel chimney connector of
minimum 24 gauge thickness, with a minimum
2in. air space between the outer wall of
chimney section and combustibles. Minimum
length of chimney section shall be 12in.
chimney section spaced 1in. away from
connector using sheet steel support plates on
both ends of chimney section. Opening shall be
covered, and chimney section supported on
both sides with sheet steel supports securely
fastened to wall surfaces of minimum 24-gauge
thickness. Fasteners used to secure chimney
section shall not penetrate chimney flue liner.
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
12
Figure 6 Trim and Mantle Clearances
OUTSIDE AIR SUPPLY
(Optional Kit #96-53400)
You can connect an outside air source directly to
this stove using an optional outside air kit. The
advantage of providing outside air directly to the
stove is that the air used by the stove for combustion
is taken from outside the residence rather than from
within the room where the stove is located.
The outside air kit for this stove allows for the direct
connection of the stove's air intake to a minimum 3"
(76 mm) diameter duct (supplied by others)* which
leads to the outside of the house. When considering
placement of the duct from the outside of the house
to the hearth, keep in mind the need to avoid
structural members of the house. The outside air kit
attaches to the underside of the stove. Refer to the
instructions provided with the kit for installation.
*An adaptor for 4” duct is available if needed. KIT
#90-53308
Figure 7 – Outside Air Kit Detail
The International Residential Code (IRC) does not
allow the outside air duct to terminate higher than
the appliance. Some building officials restrict vertical
rise
in
the
duct’s
termination.
Hearthstone
recommends the termination be at the same level, or
lower than the air intake on the stove.
Locate the termination of the duct on the outside
wall of the home in such a manner to avoid the
possibility of obstruction by snow, leaves or other
material. Screen the termination using ¼” x ¼” mesh
rodent screen and cover it with a rain/wind proof
hood (flex pipe, outside termination, mesh, and hood
supplied by others) Contact your dealer for
availability.
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
13
VENTING COMPONENTS &
CONFIGURATION REQUIREMENTS
•
DO NOT CONNECT THIS UNIT TO A CHIMNEY
FLUE USED BY ANOTHER APPLIANCE
•
Single wall connector that is at least 24 MSG or
25 MSG blued steel stovepipe.
•
Double wall connector (Rear pipe) which is used
with a listed, factory-built “Type HT" chimney or
with a masonry chimney to reduce clearances, is
available from several manufacturers, your dealer
can help you choose. Some air insulated
connector pipe models available are Simpson
Dura Vent DVL and Metalbestos DS. Security,
GSW and Ameritec also have acceptable Rear
connector pipe.
•
When used in a mobile home, a spark arrester is
required. (See page 17)
•
The chimney connector cannot pass through a
floor or ceiling, nor any attic or roof space, closet
or similar concealed space. Where venting
requires passage through a wall or partition of
combustible construction, the installation must
conform to NFPA Code 211 or CAN/CSA -
B365.
•
Be sure to follow the manufacturer’s instructions
to maintain an effective vapor barrier at the
location where the chimney of other component
penetrates the exterior of the structure
•
It is very important to follow minimum clearances
for chimney connectors to combustibles such as
walls and ceilings when installing the stove.
Typical chimney connector clearances are
outlined below. The single wall clearances are
generic; the double wall clearances shown are
specifically for Simpson DuraVent DVL and may
vary
with
other
brands.
Check
the
specifications from the manufacturer of your
connector.
COMPONENTS OF A VENTING SYSTEM
The complete venting system consists of several
components: chimney connector, wall thimble, wall
pass-through, chimney, and liner. It is absolutely
necessary that you install all of these components
and maintain the clearances to combustibles
discussed earlier to ensure a safe stove installation.
To protect against the possibility of a house fire, you
must properly install and constantly maintain the
venting system in good condition. Be sure to inspect
the chimney and chimney connector and keep it
clean. Upon inspection, immediately replace rusted,
cracked, or broken components. Failure to follow
these instructions and specified components or
using make-shift compromises can result in fire,
property damage, bodily injury, and even death.
•
The chimney connector is the stovepipe from the
woodstove to the chimney. The chimney
connector stovepipe is 6" (152 mm) diameter, 24
MSG or 25 MSG blued steel connector pipe. Do
not use aluminum or galvanized steel pipe - they
cannot withstand the extreme temperatures of a
wood fire.
•
The thimble is a manufactured (or site-
constructed) device installed in combustible
walls through which the chimney connector
passes to the chimney. It keeps the walls from
igniting. You must use a wall thimble when
installing a chimney connector through a
combustible wall to the chimney.
•
A wall pass-through (or chimney support
package) also keeps the walls from igniting. You
must use one when connecting through a wall or
ceiling to a prefabricated chimney.
•
Only install this stove to a lined masonry
chimney or an approved high temperature
prefabricated residential type building heating
appliance chimney. Do not connect this stove to
a chimney serving another appliance; you will
compromise the safe operation of both the wood
stove and the connected appliance.
•
A liner is the UL 1777 or ULC S635 (for factory
built fireplace or masonry) chimney.
You must connect your stove to a chimney
comparable to those recommended in this manual.
Do not use stovepipe as a chimney. Use stovepipe
for freestanding installations only to connect the
stove to a proper chimney.
•
WARNING: DO NOT CONNECT THIS APPLIANCE
TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
INSTALLING A VENTING SYSTEM
Attach stovepipe sections to the flue collar and to
each other with the crimped end toward the stove. If
creosote builds up, this allows the creosote to run
into the stove and not on the outside of the
stovepipe or onto the stove.
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
14
Secure all joints, including attaching the stovepipe to
the stove's flue collar, with three sheet metal screws.
Install #10 x 1/2" (3 mm x 13 mm) sheet metal
screws into the holes pre-drilled in the flue collar.
Disregarding the screws can cause joints to
separate from the vibrations that result from a
creosote chimney fire.
You can simplify connecting stovepipe by using
additional accessories such as telescoping pipes,
slip-connectors or clean-out tees. These accessories
ease the periodic inspection of your chimney, as well
as allow you to dismantle the stovepipe easily
(without moving the stove).
Install the stove as close as practical to the chimney,
while maintaining all proper clearances. Install
stovepipe that is as short and as straight as
possible. Horizontal runs of stovepipe must always
rise away from the stove at a minimum of 1/4" per
foot (21mm/m).
We do not recommend long runs of stovepipe to
increase
heat
dispersal.
Longer
lengths
of
stovepipe,
or
more
connecting
elbows,
than
necessary increase the chances of draft resistance
and the accumulation of creosote buildup.
In general, you do not need to install a stovepipe
damper with the Green Mountain 60. Some
installations,
however,
could
benefit
from
a
stovepipe damper, such as a tall chimney which can
create a higher than normal draft. In such cases, a
damper can help regulate the draft. The Green
Mountain 60 requires a draft between 0.06" and 0.1"
WC. For drafts above 0.1" WC, install a stovepipe
damper. Check the draft at stove installation time.
Remember, the NFPA recommends minimum
clearances for chimney connectors to combustibles
such as walls and ceilings. Once the stove is
installed at safe distances from these combustible
surfaces, it is also important to maintain these
connector clearances for the remainder of the
installation.
CONNECTING THE STOVE TO A CHIMNEY
You can install your Green Mountain 60 to a
prefabricated metal chimney, or to a masonry
chimney.
This room heater must be connected to (1) a listed
Type HT (2100° F) chimney per UL 103 or ULC
S629, or (2) a code-approved masonry chimney with
a flue liner. The chimney size should not be less
than the flue collar, or more than three times greater
than the cross-sectional area of the flue collar.
We recommend installing a cleanout tee where
possible
to
simplify
chimney
cleaning
and
maintenance.
Connecting to a Prefabricated Metal Chimney
There are two ways to install a prefabricated metal
chimney:
•
An interior installation where the chimney
passes inside the residence through the ceiling
and roof.
•
An exterior installation where the chimney
passes through the wall behind the stove then
up the outside of the residence.
Whenever possible, choose an interior chimney. An
interior chimney heats up quickly and retains its
heat; thus promotes a better draft and discourages
the formation of creosote. An exterior chimney does
not benefit from the warmth of the building, so it
typically operates at lower flue temperatures than an
interior chimney and may experience increased
creosote accumulation.
When connecting the Green Mountain 60 to a
prefabricated metal chimney, you must follow,
precisely, the manufacturer's installation instructions.
Use only Type HT (2100° F), prefabricated metal
chimneys listed per UL 103 or ULC S629 standards.
Ensure the size of the prefabricated chimney’s flue
is appropriate for the Green Mountain 60. The Green
Mountain 60 requires a 6" (152 mm) inside diameter
flue for new installations. A 6” diameter flue provides
adequate draft and performance. You can use an 8"
(203 mm) diameter existing flue with a reducer. An
oversized flue contributes to creosote accumulation.
(In this case, bigger is NOT better.)
When purchasing a prefabricated chimney to install
with your stove, Ensure you also purchase from the
same manufacturer the wall pass-through (or ceiling
support package), "T" section package, fire-stops
(when needed), insulation shield, roof flashing,
chimney cap, and any other required accessories.
Follow
the
manufacturer’s
instructions
when
installing the chimney and accessories. In addition,
ensure
you
maintain
all
manufacturers’
recommendations for the proper clearances to the
chimney.
Connection to a Masonry Chimney
Consider two primary elements when connecting
your stove to a masonry chimney: the chimney itself
and the thimble where the stovepipe connects to the
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
15
chimney. Use only code approved masonry
chimneys containing a proper flue liner.
Before connecting to a masonry chimney, hire a
professional to examine the chimney for cracks,
loose mortar, and other signs of deterioration and
blockage. If the chimney needs repair, complete
them before installing and using your stove. Do not
install your stove until the chimney is safe for use.
Ensure the chimney’s cleanout is complete and
working properly. To avoid a loss of draft, the
cleanout door must close completely and provide a
tight seal. If the cleanout door leaks, the chimney will
cool, your stove will perform poorly, and creosote
can form.
Ensure the size of the chimney’s flue is appropriate
for this stove and that it is not too large. Use a
masonry chimney with a maximum 6” Diameter or 8"
x 8" (203 mm x 203 mm) tile size for best results. An
oversized flue contributes to the accumulation of
creosote.
Use the following checklist to ensure that your
masonry
chimney
meets
these
minimum
requirements:
MASONRY CHIMNEY WALL CONSTRUCTION:
•
Mortared brick or modular block at least 4" (102
mm) thick – must use liner
•
A mortared rubble or stone wall – must use liner
FLUE LINER OPTIONS:
•
Tile - minimum wall thickness of 5/8" (16 mm),
installed with refractory mortar, and with at least
1" (25 mm) air space around the liner
•
Stainless steel - UL listed 6” diameter, insulated
or wrapped liner, or the space around the liner
filled with vermiculite or suitable material (these
keep the liner warmer for better performance)
•
Ensure any equivalent flue liner is a listed
chimney liner system meeting type HT
requirements or other approved material.
INTERIOR CHIMNEY REQUIREMENTS:
•
Must have at least 2" (51 mm) clearance to
combustible materials
•
Must install fire stops at the spaces where the
chimney passes through floors and/or ceiling
•
Any insulation material must be at least 2" (51
mm) from the chimney
EXTERIOR CHIMNEY REQUIREMENTS:
•
At least 1" (25 mm) clearance to combustible
materials
CHIMNEY HEIGHT REQUIREMENTS (SEE FIGURE 9):
•
At least 3 feet (0.9 m) higher than the highest
part of the roof opening through which it passes.
•
At least 2 feet (0.6 m) higher than any part of the
roof within 10 feet (3 m) measured horizontally
from the top of the chimney.
The recommended minimum chimney height is 10
feet (3 m) off the floor. The recommended maximum
chimney height is 30 feet (9m).The Green Mountain
60 requires a draft between 0.06” and 0.1” water
column. Ensure your chimney is long enough to
provide the minimum draft, and use a damper if your
installation has a required chimney height that
provides too much draft.
3'-0"
MINIMUM
10'-0"
2'-0"
MINIMUM
3'-0"
MINIMUM
2'-0"
MINIMUM
Figure 8 – Chimney Height Requirements
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
16
Figure 9 – Typical Chimney Configurations
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
17
INSTALLING IN A MOBILE HOME
Follow these special requirements for installing your
stove in a mobile home.
•
Install the stove in accordance with 24 CFR,
Part 3280 (HUD)
•
An outside air kit must be used in all mobile
home installations. See page 12 for details.
•
Permanently attach the stove to your mobile
home’s floor. Use the shipping clips that came
with the stove and fasteners long enough to
attach securely to the subfloor. (The clips and
fastener heads may be painted to minimize
visibility).
Figure 8 - Lock Down Detail
•
Install a Mobile Home Chimney & Connector
Kit*.
Each kit must include:
Stainless spark arrester cap, storm collar,
Adjustable vented flashing – 0/12 – 6/12,
Two 24” chimney pipes, 24” support box
with built-in starter section and trim.
* Install a Mobile Home Chimney and Connector Kit
conforming to US/UL103 or CAN/ULC-S629, Standard for
Factory-Built Chimneys.
•
WARNING: DO NOT INSTALL IN A SLEEPING
ROOM IN A MOBILE HOME.
•
CAUTION: MAINTAIN THE STRUCTURAL
INTEGRITY OF THE MOBILE HOME WALLS,
FLOOR, CEILING, AND ROOF WHEN INSTALLING
AND USING YOUR STOVE.
•
FAILURE TO FOLLOW THESE INSTRUCTIONS
AND SPECIFIED COMPONENTS OR USING
MAKE-SHIFT COMPROMISES CAN RESULT IN
FIRE, PROPERTY DAMAGE, BODILY INJURY,
AND EVEN DEATH.
•
Burning any fuel other than wood in this unit
could generate dangerous levels of carbon
monoxide within the living space.
•
THE FRONT DOOR MUST REMAIN CLOSED
WHEN IN OPERATION EXCEPT FOR START UP
AND LOADING. Leaving the door open during use
could cause any smoke or fire detectors in the
home to be set off or a fire could escape the
firebox and start the room on fire.
•
If this unit is installed in a mobile home, care must
be taken to ensure adequate air is available. If not
enough air is available it could starve the room of
all the oxygen. (See page 27 for more details)
Figure - 9
•
CAUTION: REMOVE THE CHIMNEY WHEN
TRANSPORTING THE MOBILE HOME!
•
Be sure to follow the manufacturer’s instructions
to maintain an effective vapor barrier at the
location where the chimney of other component
penetrates the exterior of the structure
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
18
OPERATION
Once your Green Mountain 60 is installed, you are
ready to light a fire.
Every installation, season’s firewood, and operator’s
technique varies. Learn how to use your stove most
efficiently for your installation. We can give you the
basic principles, but only you can ensure maximizing
the potential of your stove while also operating it
safely.
•
WARNING: HOT WHILE IN OPERATION! KEEP
CHILDREN, PETS, CLOTHING AND FURNITURE
AWAY. CONTACT MAY CAUSE SKIN BURNS.
Read this entire chapter before lighting your first fire.
It explains the controls and features of your wood
stove, how to choose firewood, and how to use your
stove on a daily basis.
CONTROLS AND FEATURES
Before lighting any fires, become familiar with the
location and operation of your stove's controls and
features and learn how to use them (See Figure 10).
For your own safety, do not modify these features in
any way. We recommend you use fireplace gloves
when the stove is in operation and hot.
Figure 10 - Controls & Features
FRONT DOOR HANDLE: The firebox door allows
you to load wood into your stove; a wood handle
operates the door. To open the door, pull up on the
handle and swing the door away from the stove. To
latch the door, push the door tightly towards the
firebox then continue to push the handle in and
down until it latches shut. Gently pull on the door
handle to make sure it is properly latched.
PRIMARY AIR CONTROL: The primary air control
lever is located under the ash lip. The primary air
control allows you to regulate the amount of air
entering the firebox. Generally, the more air allowed
into the firebox, the faster the rate of burn and the
higher the heat output; conversely, less air creates a
slower burn, with lower heat output. For maximum
airflow, pull the lever out as far as possible; move
the lever inwards as far as possible for minimum
airflow (does not close completely).
Figure 11 – Air Control
BYPASS HANDLE: The bypass handle controls the
bypass door inside the stove. When the handle is
pointed towards the front of the stove, the bypass
door is open, and when the handle is pointed
towards the rear of the stove, the bypass door is
closed. The bypass door directs the flow of
combustion products through or around the catalytic
combustor. When the bypass handle is open,
combustion products are directed around the
catalytic combustor. The bypass handle should be
open when first staring a fire until the catalytic
combustor heats up to activation temperature, and
whenever opening the front door to load the stove.
When the bypass handle is closed, combustion
products are directed through the catalytic
combustor. The bypass handle should be closed
once the catalytic combustor heats up to activation
temperature, and remain closed whenever the stove
is burning and in the active temperature range.
Figure 12 – Bypass Closed
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
19
Figure 13 – Bypass Open
CATALYST THERMOMETER: The catalyst
thermometer monitors the downstream temperature
of the catalysts, and indicates when the stove is in
the active range for the catalysts. When the stove is
in the “active” range, the bypass handle should be
closed. When the stove is in the “Inactive” range, the
bypass handle should be opened until the stove
heats up. If the thermometer is in the “Too Hot”
range, keep the door closed, fully close the air
control, and allow the stove to cool down until the
thermometer falls into the “Active” Range. Once the
catalyst thermometer has reached the active range,
heat generated from burning smoke keeps the
catalysts warm and active as long as fuel remains in
the stove. The Green Mountain 60 typically operates
in the 800 ⁰F to 1300 ⁰F range.
Figure 14 – Catalyst Thermometer
CHOOSING FIREWOOD
Burn only natural firewood (known as cordwood) in
the Green Mountain 60 Model 8660 Wood Heater.
This stove is not designed to burn other fuels.
•
CAUTION:
DO
NOT
USE
CHEMICALS
OR
FLAMMABLE FLUIDS TO START THE FIRE. DO
NOT
USE
CHARCOAL,
PELLETS,
COAL,
ARTIFICIAL LOGS OR ANY OTHER MATERIALS
AS FUEL; THEY ARE NOT SAFE. DO NOT BURN
GARBAGE OR FLAMMABLE FLUIDS.
•
THE USE OF UNAUTHORIZED FUEL SUCH AS
COAL COULD PRODUCE HIGH LEVELS OF
CARBON DIOXIDE IN THE LIVING SPACE. AT
HIGH LEVELS CARBON DIOXIDE COULD RESULT
IN PERSONAL INJURY OR DEATH.
The quality of your firewood directly affects heat
output, duration of burn and performance of your
stove. Softwoods generally burn hotter and faster,
while hardwoods burn longer and produce better
coals. Density and moisture content are two critical
factors to consider when purchasing wood.
The following is a list of some wood species and
their relative BTU (British Thermal Unit) content. The
higher the BTU content, the longer the burn.
Firewood with higher BTUs is generally ideal for a
wood stove.
Burn untreated wood only. Other materials such as
wood preservatives, metal foils, coal, plastic,
garbage, sulphur, or oil may damage the catalysts.
Wood Heat Value: Sorted By Btu Content
Common Name
Lb/ cord
MBTU/ cord
High
Osage Orange (Hedge)
4,728
32.9
Hickory, Shagbark
4,327
27.7
Hop Hornbeam (Ironwood)
4,267
27.3
Beech, Blue (Ironwood)
3,890
26.8
Birch, Black
3,890
26.8
Locust, Black
3,890
26.8
Hickory, Bitternut
3,832
26.7
Locust, Honey
3,832
26.7
Apple
4,100
26.5
Mulberry
3,712
25.8
Oak, White
4,012
25.7
Medium High
Beech, European
3,757
24
Maple, Sugar
3,757
24
Oak, Red
3,757
24
Ash, White
3,689
23.6
Birch, Yellow
3,689
23.6
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
20
Medium
Juniper, Rocky Mtn
3,150
21.8
Elm, Red
3,112
21.6
Coffee tree, Kentucky
3.112
21.6
Hackberry
3,247
20.8
Tamarack
3,247
20.8
Birch, Gray
3,179
20.3
Birch, White (Paper)
3,179
20.3
Walnut, Black
3,192
20.2
Cherry
3,120
20
Ash, Green
2,880
19.9
Cherry, Black
2,880
19.9
Elm, American
3,052
19.5
Elm, White
3,052
19.5
Sycamore
2,808
19.5
Ash, Black
2,992
19.1
Maple, Red
2,924
18.7
Fir, Douglas
2,900
18.1
Medium Low
Boxelder
2,797
17.9
Alder, Red
2,710
17.2
Pine, Jack
2,669
17.1
Pine, Norway (Red Pine)
2,669
17.1
Pine, Pitch
2,669
17.1
Catalpa
2,360
16.4
Hemlock
2,482
15.9
Spruce, Black
2,482
15.9
Pine, Ponderosa
2,380
15.2
Low
Aspen, American
2,290
14.7
Butternut (Walnut, White)
2,100
14.5
Spruce
2,100
14.5
Willow
2,100
14.5
Fir, Balsam
2,236
14.3
Pine, White (Eastern,
Western)
2,236
14.3
Fir, Concolor (White)
2,104
14.1
Basswood (Linden)
2,108
13.8
Buckeye, Ohio
1,984
13.8
Cottonwood
2,108
13.5
Cedar, White
1,913
12.2
Moisture content also plays a key role in the
performance of your stove. Wood freshly cut from a
living tree (green wood) contains a great deal of
moisture. As you might expect, green wood burns
poorly. You must season green wood before using it
in your wood stove. To season green wood properly,
split, stack, and allow it to air dry for a period of one
year. Green wood may provide less than 2000 Btu
per pound, whereas dry wood can provide up to
7000 Btu per pound.
Stack the firewood on skids or blocks to keep it off
the ground, cover only the top of the stack. Plastic or
tarps that cover the sides of the woodpile trap
moisture and prevent the wood from drying. As for
stacking, an old Vermonter said, "The spaces
between the logs should be large enough for a
mouse to get through, but not for the cat that's
chasing it."
•
CAUTION: DO NOT STORE FIREWOOD WITHIN
THE STOVE'S SPECIFIED CLEARANCES TO
COMBUSTIBLE MATERIALS.
BUILDING A FIRE
Once you understand the controls of your wood
stove and have the appropriate firewood, you are
ready to start a fire.
•
WARNING: NEVER USE GASOLINE, GASOLINE-
TYPE LANTERN FUEL, KEROSENE, CHARCOAL
LIGHTER FLUID, OR SIMILAR LIQUIDS TO START
OR 'FRESHEN UP' A FIRE IN THIS HEATER.
KEEP ALL SUCH LIQUIDS WELL AWAY FROM
THE HEATER WHILE IT IS IN USE.
BREAKING IN YOUR WOOD STOVE
It is imperative that your stove is "broken in"
gradually. Soapstone must be "seasoned"; over-
firing a new stove may cause soapstone to crack or
may damage other stove parts. Natural moisture in
the freshly quarried soapstone must be driven out
slowly to minimize the “shock” to the stone of its first
exposure to high firebox temperatures. In addition,
the asbestos-free furnace cement must be cured
slowly to ensure adequate sealing and bonding.
When you light your first fires, the woodstove will
emit some smoke and fumes. This is normal “off-
gassing” of the paints and oils used when
manufacturing the woodstove. If you find it
necessary, open a few windows to vent your room.
The smoke and fumes will usually subside after 10
to 20 minutes of operation. The odor and smoke will
end once the stove is “cured”.
The first few fires of the season may produce other
odors from impurities that exist in the area
immediately surrounding the stove. Some potential
impurities are cleaning solvents, paint solvents,
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
21
cigarette smoke, and soot from scented candles, pet
hair, dust, adhesives, a new carpet, and new
textiles. These odors will dissipate over time. You
can alleviate these odors by opening a few windows
or otherwise creating additional ventilation around
your stove. If any odor persists, contact your dealer
or an authorized service technician.
If you adhere to the operating procedures in this
manual, the steel, cast iron, and soapstone
components of your stove will give you many years
of trouble-free use. With use, the color of the
soapstone may change and small fractures may
appear on the surface. These changes do not affect
the function of the stove. If a panel breaks
completely, it must be replaced
Avoid the following conditions that can cause the
glass, soapstone, steel or cast iron pieces to break:
•
Do not throw wood into the stove.
•
Do not use the door as a lever to force wood into
the stove.
•
Do not load wood encrusted with ice into a
burning stove - the thermal shock can cause
damage.
•
Do not use a manufactured log grate or
otherwise support the fuel. Burn the fire directly
on the floor of the firebox.
BUILDING A BREAK IN FIRE
1) Open the bypass handle.Open the front door
and place five or six double sheets of tightly
twisted newspaper in the center of the firebox.
Arrange kindling in a crisscross pattern over the
newspaper. Kindling should be approximately
ten pieces, 1/2" (13 mm) in diameter and 10" to
16" (254 mm to 457 mm) long.
2) Fully open the primary air control by pulling the
control handle towards you, away from the
firebox.
3) Light the paper under the kindling. Leave the
door slightly ajar momentarily until the kindling
has started to burn and draft begins to pull.
4) Close the door and allow the fire to burn. Keep
the door closed while the stove is in use.
5) KEEP A WATCHFUL EYE ON YOUR STOVE to
maintain a steady, low-heat fire. Your first fire
should make the stove warm but not hot to the
touch. Visible steam, or boiling moisture and
hissing indicate the soapstone is too hot. At
most, a few small chunks of wood should be
added to the fire to reach safe break-in
temperatures.
6) Once the stove is warm but not hot to the
touch, close the primary air control by pushing it
fully inward toward the stove to allow the fire to
die out completely.
7) Let the stove return to room temperature.
Your first fire and first fire each season thereafter
should be built and maintained as outlined above.
Your patience will be rewarded by a properly
seasoned stove.
•
NOTE: The cool flue gas temperatures
present during the break-in procedure may
cause rapid creosote build-up. The door
glass may also get dirty. A good hot fire will
clean it. We recommend a visual inspection
(and
cleaning
if
necessary)
of
your
stovepipe and chimney once the break-in
procedure is completed.
NORMAL OPERATION
BUILDING A FIRE FOR EVERYDAY USE
1) Open the bypass handle. Open the front door
and place five or six double sheets of tightly
twisted newspaper in the center of the firebox.
Arrange kindling in a tee-pee configuration over
the newspaper. Use approximately 10 pieces of
kindling, 1/2" (13 mm) in diameter and 10" to 16"
(254 mm to 406 mm) long.
2) Fully open the primary air control by pulling the
lever completely out, away from the firebox.
3) Light the paper under the kindling. Leave the
front door slightly ajar momentarily until the
kindling begins to burn and draft begins to pull.
4) Close the door and allow the fire to burn.
5) Once the kindling is burning, open the front door
and add logs, small at first, to build the fire up.
Ensure you keep the logs away from the glass in
front in order for the air-wash system to work
properly. Keep the front door closed while the
stove is in use.
CAUTION: DO NOT BUILD THE FIRE TOO CLOSE
TO THE GLASS. KEEPING THE FIRE TOWARDS
THE CENTER OF THE FIRE BOX WILL KEEP
COALS FROM BUILDING UP AGAINST THE
GLASS DURING RELOADING.
6) Once the fire is burning well, and the catalyst
thermometer indicates that the stove is in the
active range, close the bypass handle. Now the
combustion products are passing through the
catalytic combustor, and your stove will be
burning at its optimal efficiency.
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
22
7) After closing the bypass door, allow the stove to
run on a high setting for around 20 minutes to
ensure the catalytic combustor stays in the
active range. This will also allow the fire to burn
off any residue on the door glass from any
previous low-burn fires
8) Use the primary air control to regulate the
desired rate of burn. Pull the handle towards you
for a higher burn rate, and push the handle
towards the stove for a lower burn rate. The air
control does not close completely.
Note: Always remember to open the bypass handle
before opening the front door. When opening the
front door to reload or re-arrange logs, it is advisable
to open the door just a crack, pause for a moment
then open the door completely. This procedure
allows the firebox to clear of smoke before the door
is open fully. In addition, reloading on a bed of hot,
red coals reduces smoking time and brings fresh
fuel up to a high temperature rapidly. During the
refueling and rekindling of a cool fire, or a fire that
has burned down to the charcoal phase, operate the
stove at a medium to high firing rate for about 10
minutes
to
ensure
that
the
catalysts
reach
approximately 600 °F. Once the catalysts reach
operating temperature, the bypass handle can be
closed. When reloading the stove, try to keep an
open path behind the Lower Primary Air Opening
(LPAO). It is helpful to leave a small valley in the
coal bed behind the LPAO to insure faster re-
lighting.
CATALYTIC COMBUSTOR OPERATION
The Green Mountain 60 uses a catalytic combustor
to ensure highly clean and efficient burns. The
catalytic combustor is made from a stainless steel
corrugation that is coated with a catalytic material.
The catalytic combustor becomes active around 500
⁰F (260⁰C), helping to burn up smoke and any
remaining particles that were not fully burned in the
firebox. During the startup of a cold stove, a medium
to high firing rate must be maintained for about 20
minutes. This ensures that the stove, catalysts, and
fuel are all stabilized and at proper operating
temperatures. Even though it is possible to have gas
temperatures reach 500 °F (260⁰C) within 2 to 3
minutes after a fire is started, if the fire is allowed to
die down immediately, it may go out or the
combustor may stop working. Once the stove and
catalytic combustor heat up, heat generated from
burning smoke keeps the catalysts warm and active
as long as fuel remains in the stove. You stove will
burn the cleanest and most efficiently when the
catalysts are in the active range. There should be
little to no visible smoke from your chimney when the
catalysts are in the active zone and fully functional.
BURN RATE
This wood heater has a manufacturer-set
minimum low burn rate that must not be altered.
It is against federal regulations to alter this
setting or otherwise operate this wood heater in
a manner inconsistent with operating
instructions in this manual
LOW BURN: Move the air control lever all the way
inward toward the stove. (See figure 13). This closes
the air shutter to its minimum opening. A low burn
rate over extended periods is not advisable as it can
promote the accumulation of creosote. Inspect the
venting system frequently if using low burn rates
consistently.
MEDIUM LOW BURN: With the primary air control
in the low position, pull the air control forward (a little
less than 1/4”). A medium-low burn rate is the typical
setting and is preferable if the stove is unattended.
At this burn rate, a little goes a long way.
MEDIUM HIGH BURN: With the primary air control
in the low position, pull the air control forward (a little
less than 1/2”)
HIGH BURN: Completely open the primary air
control by moving it all the way outward toward the
operator. Fully load the firebox with wood on a bed
of hot coals or on an actively flaming fire. To
minimize creosote accumulation, run the stove on
high once or twice daily for 35 to 45 minutes to fully
heat the stovepipe and chimney.
CAUTION: Do not burn fuel other than cordwood in
your stove.
Figure 15 – Air Control Position
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
23
OVER-FIRE CAUTION
Over-firing means the stove is operating at
temperatures above normal temperatures reached
during High Burns outlined in the BURN RATE
section. Carefully avoid over-firing, as it will damage
the stove. Symptoms of chronic over-firing can
include warped components, short burn times, a
roaring sound in the stove or stovepipe, and
discoloration of the stovepipe. A properly installed
stove using fuel and following operating procedures
as outlined in this manual should not over-fire.
Excessive draft, inappropriate fuel, and operator
error can cause over-firing. Correct an over-fire
situation as follows:
•
EXCESSIVE DRAFT: Contact your local dealer
to have a draft reading taken. Any draft in
excess of 0.1 WC requires a damper in the
stovepipe. Some installations may require more
than one damper.
•
INAPPROPRIATE FUEL: Do not burn coal; kiln
dried lumber, wax logs, compressed wood,
highly volatile fuels or combustibles, or anything
other than natural cordwood.
•
OPERATOR ERROR: Ensure all the gaskets
are in good condition. Replace worn out or
compressed gaskets. Only burn the stove with
the firing and ash doors in the closed position.
If you suspect your stove is over-firing, discontinue
use and contact your dealer immediately. Damage
caused by over-firing is not covered by your
warranty. Results of over-firing can include warped
or burned out internal parts, cracked refractory
panels, discolored or warped external parts, and
damaged finish.
•
ANY SIGNS OF OVER-FIRING WILL VOID YOUR
WARRANTY!
•
THE FRONT DOOR MUST REMAIN CLOSED
WHEN IN OPERATION
REMOVAL AND DISPOSAL OF ASHES
You can leave a thin layer of ashes in the firebox if
preferred. Allow fire to die down or go out
completely. It is important to prevent ashes from
building up around the front door opening or they will
spill out, or they can pack into the gasket channel
and prevent proper sealing. To remove ashes, use a
fireplace shovel. Avoid removing large live coals by
pushing them to the side and removing only the finer
ash with a shovel.
Disposal of ashes - Ashes should be placed directly
into a metal container with a tight fitting lid. Do not
place any other items or trash into the metal
container. Do not pour water into the container.
Replace the container’s lid and allow the ashes to
cool. Never place the ash disposal container on a
combustible surface or vinyl flooring, as the
container could be hot!
Pending disposal, place the closed ash container on
a noncombustible floor or on the ground outside,
well away from all combustible materials, liquid fuels,
or vehicles. Retain ashes in the closed container
until all coals thoroughly cool.
If the ashes are disposed of by burial in soil or
otherwise locally dispersed, they should be retained
in the closed container until all cinders have
thoroughly cooled.
NEVER place ashes in wooden or plastic containers,
in trashcans with other trash, or in paper or plastic
bags, no matter how long the fire has been out.
Coals within a bed of ashes can remain hot for
several days once removed from the firebox.
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
24
MAINTENANCE
CATALYTIC COMBUSTOR INSPECTION AND
REPLACEMENT PROCEDURES
• WARNING: THIS WOOD HEATER CONTAINS A
CATALYTIC COMBUSTOR, WHICH NEEDS
PERIODIC INSPECTION AND REPLACEMENT FOR
PROPER OPERATION. IT IS AGAINST FEDERAL
REGULATIONS TO OPERATE THIS WOOD
HEATER IN A MANNER INCONSISTENT WITH
OPERATING INSTRUCTIONS IN THIS MANUAL, OR
IF THE CATALYTIC ELEMENT IS DEACTIVATED
OR REMOVED
It is important to periodically monitor the operation of
the catalytic combustor to ensure that it is
functioning properly and to determine when it needs
to be replaced. A non-functioning combustor will
result in a loss of heating efficiency, and an increase
in creosote and emissions. Following is a list of
items that should be checked on a periodic basis
-Combustors should be visually inspected at least
three times during the heating season to determine if
physical degradation has occurred. Actual removal
of the combustor is not recommended unless more
detailed
inspection
is
warranted
because
of
decreased performance. If any of these conditions
exists, refer to Catalyst Troubleshooting section of
this owner’s manual.
-This catalytic (or hybrid) heater is equipped with a
thermometer to monitor catalyst operation. Properly
functioning
combustors
typically
maintain
temperatures in excess of 500 °F, and often reach
temperatures in excess of 1,000 °F. If catalyst
temperatures are not in excess of 500 °F, refer to
the
Catalyst Troubleshooting section of this owner’s
manual.
-You can get an indication of whether the catalysts
are working by comparing the amount of smoke
leaving the chimney when the smoke is going
through the combustor and catalysts light-off has
been achieved, to the amount of smoke leaving the
chimney when the smoke is not routed through the
combustor (bypass mode).
1.
Light stove in accordance with operator’s
instructions
2.
With smoke routed through the catalysts, go
outside and observe the emissions leaving the
chimney.
3.
Engage the bypass mechanism and again
observe the emissions leaving the chimney.
Significantly more smoke will be seen when the
exhaust is not routed through the combustor
(bypass mode)
INSPECTING THE CATALYSTS AND
REMOVING/REPLACING THE BAFFLE
1.
Allow the stove and ashes to fully cool.
2.
Remove the metal baffle protector by sliding it
to the left or right, and then rotating it towards
you.
3.
Lift up on the right side baffle, and gently pull
the left side baffle down and out of the stove
CAUTION - Do not force the baffle pieces. Gently
adjust the baffle orientation until each side can
be removed freely from the stove.
Figure 17 - Removing/Replacing the Baffle for
Inspection
4. Use a small vacuum nozzle or soft bristled
brush to remove any accumulated ash or
soot on the face of the catalyst.
5. Inspect the catalyst for any unusual warping,
corrosion, or plugged openings.
Figure 16 - Removing/Replacing the Baffle for Inspection
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
25
Figure 18 (cont.) - Removing/Replacing the Baffle for Inspection
Figure 19 – Catalyst Access Door
4. Use a small vacuum nozzle or soft bristled
brush to remove any accumulated ash or
stoot on the face of the catalysts.
5. Inspect the catalysts for any unusual
warping, corrosion, or plugged openings.
6. If any unusual conditions are found, remove
the catalyst blocks – See replacing the
catalysts.
7. Replace the baffles and baffle protector.
Installation is the opposite of removal.
8. Ensure that the baffle pieces are pushed
together at the center joint.
REMOVING OR REPLACING THE CATALYSTS
Refer to the Catalytic combustor warranty on page
35 for catalyst replacement information. DO NOT
OPERATE UNIT WHITOUT CATALYSTS.
1. Allow the stove and ashes to fully cool.
2. Loosen, but do not remove the screws
securing the rear heatshield. (If stove is so
equipped).
3. Remove the heat shield by sliding the screw
heads through the slots in the heatshield.
4. Remove the 2 bolts securing the cast iron
catalyst access cover, and remove the cover.
5. Inspect the catalysts for visible damage or fly
ash. If fly ash exists, gently brush the
catalysts off with a narrow soft-bristle brush,
or vacuum with a crevice tool.
6. If fly ash exists, or if there are suspected
catalyst performance issues, fully remove the
catalysts by gently pulling upwards from the
ribs in the cast iron, and then pulling
outwards through the catalyst access
opening.
7. Remove any remaining gasket material from
the opening and from the catalysts.
8. Inspect the catalysts for any fly ash or
clogging, and remove with a soft bristled
brush or vacuum crevice tool. If extra
cleaning is needed, follow the guidelines
below:
-You may use compressed air under 35
psi, air only, no chemicals.
-You may soak the catalysts in a hot water
mix (not boiling), 4 parts water, 1 part
vinegar. Rinse with cold water until
vinegar smell is mostly gone.
-No metal tools such as gun cleaners
should be used.
-No detergents or chemicals.
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
26
9. Only remove the catalysts if required. In
general, the less you handle the catalysts,
the better. If any unusual conditions are
found, remove the catalyst blocks – See
replacing the catalysts.
10. Some warping or bowing of the catalysts over
time is acceptable, as long as the catalyst
gasket continues to seal. Measure the
catalysts in the middle section – if the
dimensions are outside the range shown in
Figure 20 on the next page, replace the
catalysts.
11. Remove existing gasket material from the
catalysts.
12. Beginning at one corner, re-install fiberglass
gasket material on the catalysts.
13. Wrap the gasket tape around the catalysts so
it is reasonably tight. Double layer the
material on three sides of the individual
catalyst cartridges as shown in the following
picture.
14. Once the gasket is installed on the catalysts,
gently push the catalysts into the catalyst
opening until the catalysts hit against the
bottom wall of the cavity. Take care to ensure
the gasket is not damaged and position the
two cartridges so that the single layer gasket
edges touch one another in the center.
.
15. Replace the catalyst access door.
16. Heat the stove slowly during your next fire to
allow the fiberglass gasket to properly seat
and seal the catalysts.
REPLACING THE REFRACTORY STONE AND
SECONDARY RISER ASSEMBLY
1. Allow the stove and ashes to fully cool.
2. Open the front door of the stove and fully
clean any ash in the firebox
3. Remove the baffle following the instructions
in “Inspecting the Catalysts and
Removing/Replacing the baffle.
4. Remove the side stones one at a time by
tipping them towards the inside of the
firebox from the top.
5. With side stones and baffle removed, the
secondary riser assembly and rear stones
can be lifted up and out of the stove.
Figure 20 - Acceptable Catalytic Distortion
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
27
Figure 22: Front Door assembly
Figure 21 - REMOVING RISER AND REAR STONES
6. Installation is the reverse of
disassembly. Make sure that the
secondary riser tube is seated in the
pocket at the rear of the bottom
casting.
GLASS REPLACEMENT PROCEDURES
•
WARNING: DO NOT OPERATE THIS APPLIANCE WITH THE GLASS PANEL REMOVED, CRACKED, OR
BROKEN. DO NOT SUBJECT THE DOOR TO ABUSE, SUCH AS STRIKING OR SLAMMING SHUT. ONLY A
QUALIFIED SERVICE PERSON SHOULD REPLACE THE GLASS PANEL.
Required Glass Kit: Part Number: 96-58607. Use only 4mm x 343mm x 459mm Ceramic, or Neoceram
glass. Contact your Hearthstone dealer.
1. Follow the instructions included with the
replacement glass kit.
2. Remove the door.
3. Remove the screws from the glass clips (use
penetrating oil if necessary) – Set aside for
reinstallation.
4. Carefully lift the damaged glass off the door
and discard.
5. Remove any remaining glass and old gasket
material.
6. Clean the screw holes and place a small
amount of anti-seize compound in each one.
7. Install a new glass gasket in the glass gasket
groove.
8. Place the new glass onto the door.
9. Important! Center the glass and ensure that
the edges of the glass are parallel with the
edges of the opening.
10. Check glass position again (centered, and
parallel), then screw the glass retainer clips
with the glass pads back on the door using a
crisscross pattern. Tighten the screws no
more than 1/8th of a turn after they seat. The
glass will break at this point if not positioned
correctly.
11. Apply a light film of anti-seize lubricant on the
door’s hinge pins if needed.
12. Install the door.
13. After 5 or 6 fires, check the glass retainer
screws, and retighten if necessary.
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
28
CREOSOTE FORMATION & REMOVAL
When wood burns slowly at low temperatures, it may
produce tar and other organic vapors, which
combine with expelled moisture to form creosote.
These creosote vapors condense in the relatively
cool chimney flue of a slow-burning fire. As a result,
creosote residue accumulates on the flue lining.
When ignited, this creosote makes an extremely hot
fire, which may damage the chimney or even destroy
the house. When burning wood, inspect the chimney
connector and chimney at least once every two
months during the heating season to determine if
there is a creosote buildup.
If a creosote build-up occurs, inspect the stovepipe
connector and chimney more often, at least monthly
during
the
heating
season
to
monitor
the
accumulation. If a creosote residue greater that 1/4"
(6 mm) accumulates, remove it to reduce the risk of
a chimney fire.
PREVENTION
Burn the stove with the primary air control fully open
for 35 - 45 minutes daily to burn out creosote
deposits from within the stove and the venting
system.
After reloading with wood, burn the stove with the
primary air control fully open for 15 to 20 minutes.
This manner of operation ensures early engagement
of the secondary combustion system that minimizes
creosote buildup in the chimney.
If your glass always remains dirty, your operating
temperatures are too low or your wood is wet;
therefore, there is a higher risk of creosote buildup.
Inspect the venting system at the stove connection
and at the chimney top. Cooler surfaces tend to
build creosote deposits faster, so it is important to
check the chimney at the top (where it is coolest) as
well as from the bottom near the stove.
CLEANING
Remove accumulated creosote with a cleaning
brush specifically designed for the type of chimney
in use. We recommend you use a certified chimney
sweep to perform this service. Contact your dealer
for the name of a certified chimney sweep in your
area (your dealer may be a certified sweep!).
We recommend that before each heating season
you have the entire system professionally inspected,
cleaned and repaired, if necessary.
GASKETS
Replace door gasket material every two to three
seasons, or whenever it becomes deteriorated or
loose, depending on stove use. If the door seal
leaks, a new gasket will ensure a tight seal and
improve stove performance.
We
recommend
you
only
use
Hearthstone
replacement gaskets when you need to replace your
door gasket. Contact your dealer for a gasket kit that
includes instructions, and the gasket for your stove.
GLASS
The glass used in our stoves is actually not plain
glass, but a tough, clear ceramic material capable of
operating at temperatures up to 2300° F. Do not
operate the stove with a broken door glass. Do not
abuse the front door by striking or slamming.
When necessary, clean the glass. For the inside
surface of the glass, we recommend using a damp
paper towel dipped in gray ash. Rub the inside of the
glass with a circular motion. When all the deposits
are removed, clean up with window cleaner or with
commercial
stove
glass
cleaners,
which
are
available from your local dealer. Use this type of
cleaner for the outside surface as well. Never
attempt to clean the glass while the fire is burning or
while the glass is hot. Remove deposits by following
the instructions provided with the cleaner. Wipe the
cleaner off with a soft cloth, or black & white
newsprint.
Important: scratching or etching the glass
will weaken the integrity of the glass. Do not
use a razor blade, steel wool, or any other
abrasive material to clean the glass. Use a
cleaner
specifically
manufactured
for
woodstoves only.
The front door glass is a ceramic, thermal shock-
resistant glass, made specifically for use in
woodstoves. Do not use any replacement glass
other than the ceramic glass manufactured and
supplied for use in this woodstove. Replacement
glass is available through your local dealer.
Replace the door glass immediately if broken or
chipped. Contact your local dealer for replacement
glass. The glass kit includes instructions and
everything needed for the repair. If you replace the
glass yourself, wear work gloves and safety glasses.
Required Glass Kit: PN: 96-58607.
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
29
TROUBLESHOOTING
COMMON ISSUES
Virtually all woodstove operators experience basic
common problems at one time or another. Most are
correctable and generally require only a minor
adjustment of the stove, installation, or operating
technique. In cases where weather conditions
dramatically affect stove performance, the problems
are typically temporary and solve themselves once
the weather changes.
If you question whether your stove is producing
adequate heat, the best way to troubleshoot the
problem is to monitor the temperature of the stack
no more than 12 inches (30 cm) above the flue
collar. A 400° F (200° C) stovepipe confirms the
stove is supplying sufficient heat. Keep in mind that
your
house
itself
will
regulate
room/house
temperatures. How well the walls, floors and ceilings
are insulated, the number and size of windows, the
tightness of outside doors, and the construction or
style of your house (vaulted ceilings or other open
spaces which collect large percentages of heat,
ceiling fans, etc.) all are determining factors of room
temperature.
Your stove's performance is also dependent on its
installation.
One
common
cause
of
poor
performance
is
an
oversized
chimney
flue.
Oversized chimney flues result in decreased draft,
which prevents the smoke from rising out the
chimney. Oversized flues are also more difficult to
heat effectively, especially when burning a high
efficiency stove. Cool flue temperatures inhibit the
establishment of a strong draft (and encourage the
accumulation of creosote). The lack of a strong draft
will cause the fire to die down and may even force
smoke to pour into the room.
If your chimney is the proper size and a strong draft
is not easily established, there is the possibility that
the chimney is too cold. Again, hot chimneys
promote stronger drafts. Opening a window briefly in
the room while lighting the stove may help.
Other draft guidelines are as follows:
An "AIRTIGHT" HOUSE: The air supply (infiltration)
to the interior of the house may be inadequate if
your home is super-insulated or especially well
sealed. This phenomenon of air starvation within the
building is exacerbated if exhaust fans, such as
clothes dryers, bathroom fans or cook stove exhaust
fans, are in operation within the home. Outfitting
your stove with the optional outside air adaptor
connected to an air duct, which leads to the outside
of the building, can correct this problem.
Tall Trees or Buildings: These obstructions, when
located close to the top of the chimney can cause
chronic or occasional downdrafts. When selecting a
site for a new chimney, consider the placement of
other objects near the proposed chimney location.
Wind Velocity: Generally, the stronger and steadier
a wind, the stronger (better) the draft. However,
"gusty"
wind
conditions
can
cause
erratic
downdrafts. For consistent problems, consider a
high wind cap, such as the Vacu-Stack.
Barometric Pressure: Chimney drafts are typically
sluggish on balmy, wet or muggy days (low
barometric pressure). This is a weather-related
phenomenon, which generally is self-correcting as
the weather changes.
Briskness of Fire: The hotter the fire in your stove,
the hotter your chimney and, therefore, the stronger
the draft.
Breaks in the Venting System: An unsealed
clean-out door at the bottom of the chimney, leaky
stovepipe
joints,
a
poor
stovepipe-to-thimble
connection, missing caps, or a leaky chimney all can
cause inadequate draft.
Seasonal Factors: Early fall and late spring are
generally difficult seasons in which to establish
proper drafts. The colder the outside air is relative to
room temperature, the stronger the draft.
OPERATING THE STOVE
As outlined above, there are days when a good draft
is just not easy to establish. The causes are usually
seasonal factors or a cold chimney. Try starting the
fire by using small kindling and fuel to obtain a quick,
hot fire. Tend the fire frequently with small fuel until
the chimney is hot and the draft is well established.
Sometimes, partially opening a first floor window
briefly will help quickly get draft established.
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
30
TROUBLESHOOTING GUIDE
PROBLEM
POSSIBLE CAUSE
SOLUTIONS
STOVE
SMOKES
Operating Technique
Fully open the primary air control one minute before opening
doors, and ensure the bypass is open before opening door.
Cold Chimney or reverse
draft
Preheat the chimney when first starting a fire. Briefly open a
window in the room containing the stove.
Blocked Chimney
Examine the chimney and stovepipe for blockage or creosote
accumulations.
Oversized Chimney
Reline the chimney to the appropriate diameter
Undersized Chimney
Install a draft inducer or replace the chimney.
Chimney Too Short
Lengthen the chimney.
Air Infiltration Into The
Chimney
Seal chimney connections and openings. Check clean-out
doors.
Bypass not closed
Ensure that the bypass door is closed when the catalysts are in
the active range.
Catalysts not functioning
Inspect catalysts for damage, ash build-up, or plugging. Brush
catalysts with a soft-bristled brush, or vacuum lightly. Replace if
required. Follow instructions to ensure catalyst light-off.
Not burning proper fuel
Ensure cordwood is seasoned and dry.
More Than One
Appliance Connected to
the Flue
Disconnect all other appliances and seal openings.
BACK-PUFFING
OR GAS
EXPLOSIONS
Operating Technique
Fully open the primary air control one minute before opening the
door and keep it fully open for a few minutes after reloading.
Ensure the bypass door is open before opening the door
Extra Low Burn Rate
Burn the stove at a higher burn rate.
Chimney Down-draft
Install a chimney cap.
Excessive Ash Build-up
Empty the ash pan more frequently. Increase efficiency of
burns, and avoid using poor quality or green wood.
UNCONTROLL-
ED OR SHORT
BURN
Unsealed or Open Door
Close the door tightly or replace the gaskets.
Air leakage around glass gasket – replace gasket
Excessive Draft
Check the installation. Operate at LOW BURN. Install stovepipe
damper. Draft in excess of 0.1 wc should be corrected with a
stovepipe damper(s)
Extra Long Chimney
Shorten the chimney. Install stovepipe damper(s).
Oversized Chimney
Reline the chimney to the proper diameter.
High Winds or Hilltop
Location:
Install a chimney cap.
INSUFFICIENT
HEAT
Poor Quality, low Btu
content, or Green Wood
Use only air-dried wood, preferably dried at least one year. Use
a wood with a high Btu content if available.
Low Burn Rate
Operate the stove at a higher burn rate.
Cold Exterior Chimney
Reline or insulate the chimney.
Leaky Stovepipe or
Chimney
Check the installation. Replace with a pre-fabricated insulated
chimney system or a properly sized masonry chimney.
Too Much Heat Loss
From House
Add insulation, use energy efficient windows, or caulk windows,
and seal openings in home.
Excessive Ash Build-up
Empty the ash pan more frequently. Increase efficiency of
burns, and avoid using poor quality or green wood.
BLISTERING
OF FINISH
Operating Technique
Do not over-fire the stove. Monitor stove temperatures. Use
seasoned wood only.
Excessive Draft
Check the DRAFT. A damper may be required. Operate the
stove at a LOW BURN range.
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
31
ADDITIONAL CATALYST TROUBLESHOOTING GUIDE
PROBLEM
POSSIBLE CAUSE
SOLUTIONS
FLY ASH BUILD
UP ON
CATALYSTS
Catalysts have not
maintained light-off
temperature
Brush cold combustor with soft-bristled brush or vacuum lightly.
Follow instructions in the manual for a proper catalyst light-off
Burning materials that
cause a lot of char and
fly-ash
Don’t burn cardboard, gift wrap paper, or garbage. Burn only
dry, seasoned wood, per the owner’s manual.
Bypass closed too soon
Follow instructions in the manual for a proper catalyst light-off
CATALYSTS
PLUGGING OR
MASKING
(SOOT/CRESO-
TE)
Burning wet, pitchy
woods, or burning large
loads of small diameter
wood with the combustor
in the operating position
without catalyst light off
occurring
Burn dry seasoned wood. Follow instructions in the manual for a
proper catalyst light-off, and ensure catalyst light-off as occurred
before closing bypass damper. It may be possible to burn the
soot or creosote off by building a hot fire, and allowing the stove
to run until the catalysts are well within the operating range
before closing the bypass. Continue to run the stove at a high
temperature for one hour, while ensuring the catalysts stay in
the upper operating range, but not too hot.
WARPING OR
BOWING OF
THE
CATALYSTS
Excessive catalyst
temperatures for long
periods of time.
Ensure that the catalysts remain in the operating zone, and
does not get to hot. Reduce air control settings for a lower burn
rate to ensure catalyst temperatures do not exceed the
operating range.
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
32
REPLACEMENT PARTS & OPTIONAL ACCESSORIES
Refer to the Illustrated Parts list for further detail about stove components, available online at
www.hearthstonestoves.com.
PART #
DESCRIPTION
REPLACEMENT PARTS
5660-002
BOTTOM HEAT SHIELD
5640-008
HINGE PIN
5640-009
HINGE BLOCK
5660-010
SECONDARY AIR RISER ASSEMBLY
5660-012
TIE ROD
5660-016
BAFFLE GUARD
5640-018
BYPASS ROD RETAINER
5640-020
LATCH STRIKER PLATE
5640-022
DOOR LATCH
5660-024
REAR SHIELD (INCLUDED)
7200-520
CATALYST THERMOMETER
REPLACEMENT KITS AND ACCESSORIES
96-58400
GASKET KIT
96-58607
GLASS KIT
96-71400
HANDLE KIT
96-73400
FRONT DOOR LATCH KIT
96-75400
CATALYST REPLACEMENT KIT
96-76600
BAFFLE KIT
96-57400
BLOWER KIT
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
33
SAFETY LABEL
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
34
LIMITED WARRANTY
These warranties give you specific legal rights. You may also have other rights, which vary from State
to State.
Hearthstone Quality Home Heating Products, Inc. (Hearthstone) warrants to the original retail purchaser only
(the “Original Purchaser”) the new appliance manufactured by Hearthstone, purchased by the Original
Purchaser and installed by an authorized Hearthstone dealer or their designated representative against any of
the occurrences listed in this document that result from defects in material or workmanship. This warranty is not
transferrable. All obligations of Hearthstone under this document commence on the date of the Original Invoice
(the “Purchase Date”). The term “Limited Lifetime” is defined as 10 years from the beginning of warranty
coverage.
Hearthstone appliances are designed to be operated only with the fuels listed in your owner’s manual.
Catalytic combustor LIMITED LIFETIME WARRANTY: The catalytic combustors are covered directly by the
combustor manufacturer, Applied Ceramics. Included with your stove you will find the LIMITED LIFETIME
WARRANTY for the catalysts, as well as a warranty card.
Catalyst Model Number:
ACI-6M2
Catalyst Manufacturer: APPLIED CERAMICS
APPLIED CERAMICS warrants to the consumer who purchases a FIRECAT STEEL COMBUSTOR as a
component in an EPA certified solid fuel appliance, to replace at no charge to the consumer the FIRECAT
STEEL COMBUSTOR that ceases to function with two (2) years from the date of purchase by the original
consumer, provided that the following conditions are met:
(1) A copy of the original bill of sale that includes place and date of purchase must be submitted with
the warranty claim.
(2) The original FIRECAT STEEL COMBUSTOR must be returned to APPLIED CERAMICS
(3) The FIRECAT STEEL COMBUSTOR must not have been mechanically abused, nor must the
wrong fuels have been used in the appliance.
If after two years the FIRECAT STEEL COMBUSTOR fails to function, the prorated warranty will allow
replacement at the following special price schedule:
Year 3
$130.00
Year 4
$140.00
Year 5
$150.00
Year 6
$160.00
Year 7 and after at current retail price
Conditions 1, 2, and 3 also apply to the Prorated portion of the warranty. Any EPA certified solid fuel appliance
will receive one replacement catalyst for each defective catalyst returned during the three year period. The
consumer will be responsible for any removal, any servicing, and return of any items required for filing the
warranty claim. This warranty is APPLIED CERAMIC’S exclusive warranty, and APPLIED CERAMICS,
disclaims any other express or implied warranty for the FIRECAT STEEL COMBUSTOR, including any warranty
or merchantability fitness for a particular use.
Ensure the catalyst is well wrapped and padded for shipment in bubble wrap, or similar material. Ship the
catalyst with padding inside of a cardboard box.
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
35
All warranty claims must include $12.50 for postage and handling within the continental U.S. Alaska and
Canada claims must include $35.00.
Please allow 2-3 weeks for delivery. Order online @ www.firecatcombustors.com
Please read and understand the full warranty. Please return the completed warranty card promptly to Applied
Ceramics. The warranty card, and any warranty claims can be shipped to:
Applied Ceramics
55555 Pleasantdale Road
Doraville, GA, 30340
Stove components Limited Warranty
Warranty
Period
Wood
Gas
Pellet
Covered Components
Limited Lifetime
XXX
Stone
XXX
Cast iron not listed elsewhere
X
Clean burning air supply system*
5 Year
XXX
Door handles and latches
XXX
Steel Components and Firebox
X
Burner and logs
3 Year
X
Burn Pot and Baffles
2 Year
XXX
Appliance Electrical and Gas
Components
XX
Refractory, Vermiculite Panels, Baffles
1 Year
XXX
Enamel finish against peeling or fading
XXX
Accessories
XXX
Glass
X
Ash Grate
XXX
All components not listed elsewhere
Any parts repaired or replaced during the limited warranty period will be warranted under the terms of the limited
warranty for a period not to exceed the remaining term of the original limited warranty or one year, whichever is
longer.
Parts: Hearthstone will replace through an authorized dealer, defective parts covered by the foregoing warranty
at no charge.
Labor: Within the first (1st) year after the Purchase Date, Hearthstone will pay for warranty labor performed by
an authorized Dealer at Hearthstone’s published labor rates in effect at the time the labor is performed only if
the appliance is installed by an authorized dealer or their designated representative. Otherwise or thereafter, the
Original Purchaser is responsible for the cost of labor.
Shipping cost for parts: Within the first ninety (90) days after the Purchase Date, Hearthstone will pay for the
shipping of appliance parts covered by any of the foregoing warranties to and from Hearthstone or an authorized
Dealer, as the case may be. Thereafter, the Original Purchaser is responsible for all shipping costs related to
shipping appliance parts to and from Hearthstone or an authorized Dealer, as the case may be.
Shipping cost for the appliance: Within the first (1st) year after the Purchase Date, if the Original Purchaser is
instructed to return the appliance to Hearthstone or an authorized Dealer for repair, Hearthstone will pay fifty
percent (50%) and the Original Purchaser will pay fifty percent (50%) of the shipping costs related to shipping
the appliance to and from Hearthstone or an authorized Dealer, as the case may be. Thereafter, the Original
Purchaser is responsible for one hundred percent (100%) of all of the shipping costs related to shipping the
appliance to and from Hearthstone or an authorized Dealer, as the case may be. Notwithstanding any other
provision of this document, in no event will Hearthstone pay for any Dealer fees or other fees for pick up or
delivery of the appliance returned for repair; the Original Purchaser shall be responsible for any such fees.
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
36
EXCLUSIONS & CONDITIONS
The warranties contained in this document do not cover, nor is Hearthstone responsible for:
1. Damages resulting from:
a. Failure to install, operate, or maintain the appliance in accordance with the owner’s manual, operating
instructions, installation instructions, or safety rating label provided with the appliance.
b. Over-firing the appliance. Over-firing can be identified by, but not limited to, warped cast iron or steel,
rust colored cast iron, bubbling, cracking and discoloration of steel or enamel finishes.
c. Failure to install the appliance in accordance with all national or local building codes.
d. Shipping or improper handling.
e. Improper operation, abuse, misuse, continued operation with damaged, corroded, or failed components,
accident, or improper/incorrect service or repairs.
f.
Environmental conditions, inadequate ventilation, negative pressure, or improper drafting caused by
tightly sealed constructions, insufficient make-up air supply, or air handling devices such as exhaust
fans, forced air furnaces, or other such causes.
g. Damage caused by direct exposure to water.
h. Use of fuels other than those specified in the owner’s manual.
I.
Installation or use of components not supplied with the appliance, or any other components not
expressly authorized and approved by Hearthstone.
J. Modifications of the appliance not expressly authorized and approved by Hearthstone in writing
K. Interruptions or fluctuations of electrical power supplied to the appliance.
2. All stones are warranted against cracking or breakage due to thermal stress, excluding surface and hairline
cracks and scratches that do not affect the operation, or safety of the appliance.
3. Repair or replacement of wear parts. Such parts that are subject to normal wear and tear during the
warranty period such as paint, gaskets, baffles, refractory materials, ash grates, and glass.
4. Damage resulting from installation, modification, alteration, repair or service of the appliance by any party
other than an authorized Hearthstone dealer (a “Dealer”) or their designated representative, or Hearthstone.
5. Damage due to water or condensation due to installation of the appliance in a high moisture area.
6. Damage due to installation of the appliance in an atmosphere contaminated by damaging chemicals,
including but not limited to chlorine, fluorine or salts.
7. Scratches on glass, enameled surfaces or stones due to mechanical abrasion.
8. Noise caused by expansion or contraction caused by the heating and cooling of the appliance.
9. Odors caused by the heating of the appliance, or surrounding materials
10. Consequential damage caused by leaking of condensate during startup
11. A defect in any part of the appliance if the Original Purchaser fails to comply with Hearthstone’s or a
Dealer’s request to ship the part or the appliance to Hearthstone or a Dealer, as the case may be.
12. Replacement stones and enameled parts are taken from current stock, and may not match originals in color,
grain, or pattern. Hearthstone will supply replacement parts for discontinued parts in finishes or colors as
available, or at their discretion.
13. Hearthstone’s obligation under this warranty does not extend to the appliance’s ability to heat the desired
space. Information is provided to assist the customer and the dealer in selecting the appropriate appliance
for the application. Consideration must be given to appliance location and configuration, environmental
conditions, insulation and air tightness of the structure.
THE WARRANTIES CONTAINED IN THIS DOCUMENT ARE EXCLUSIVE AND ARE GIVEN BY
HEARTHSTONE AND ACCEPTED BY THE ORIGINAL PURCHASER IN LIEU OF ALL OTHER EXPRESS
WARRANTIES AND ANY OBLIGATIONS, LIABILITIES, RIGHTS, CLAIMS, OR REMEDIES IN CONTRACT OR
TORT, WHETHER OR NOT ARISING FROM HEARTHSTONE’S NEGLIGENCE, ACTUAL OR IMPUTED. ALL
IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, ARE GIVEN ONLY TO THE EXTENT REQUIRED BY FEDERAL OR STATE LAW.
EXCEPT AS OTHERWISE REQUIRED BY STATE LAW, UPON THE EXPIRATION OF THE EXPRESS
LIMITED WARRANTIES CONTAINED HEREIN, NO IMPLIED WARRANTIES, INCLUDING THE IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, SHALL APPLY TO
THE SUBJECT APPLIANCE. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED
WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
Hearthstone Quality Home Heating Products, Inc ® Green Mountain 60 (Model 8660)
37
THE WARRANTIES CONTAINED IN THIS DOCUMENT EXTEND ONLY TO THE ORIGINAL PURCHASER OF
THE APPLIANCE WARRANTED HEREUNDER. THEY ARE NOT TRANSFERRABLE AND DO NOT EXTEND
TO ANY SUBSEQUENT OWNERS.
UNDER NO CIRCUMSTANCES SHALL HEARTHSTONE BE LIABLE TO THE ORIGINAL PURCHASER OR
ANY OTHER PERSON FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT
LIMITED TO DAMAGE TO PROPERTY OR PERSONAL INJURIES, WHETHER ARISING OUT OF LOSS OF
USE, BREACH OF WARRANTY, TORT, OR OTHERWISE, EVEN IF HEARTHSTONE HAS BEEN
APPRAISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE
EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE
LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.
QUALIFYING FOR WARRANTY COVERAGE
To obtain performance of any obligation under this document, the Original Purchaser must, within the applicable
warranty time period, contact their original Hearthstone dealer, or the current responsible local Hearthstone
dealer, for instructions regarding the return of defective parts for repair, the return of the appliance for repair, or
to schedule a Dealer service call. The Original Purchaser should refer to the Dealer Network search engine
contained on Hearthstone’s Web site (www.hearthstonestoves.com) if the original dealer is not available, to find
a Hearthstone dealer nearest to the Original Purchaser’s location.
REMEDY
The remedy for any breach of the foregoing warranties will consist of repair or replacement, at Hearthstone’s
option, of any covered defect in the appliance. When the Original Purchaser contacts a Hearthstone Dealer, the
Dealer on behalf of Hearthstone, as the case may be, will instruct the Original Purchaser to either return the
defective part, or the entire appliance (if requested), to the Dealer or Hearthstone or allow a Dealer to make a
service call at the place where the appliance is located. Hearthstone may require that a digital picture be
provided to support the claim. Notwithstanding any other provision of this document, the Original Purchaser
shall pay for any fees and service charges related to a Dealer’s service call or the shipping charges associated
with the return.
WARRANTY REGISTRATION
The Original Purchaser can complete their warranty registration on our website at www.hearthstonestoves.com, or send a
completed and signed Warranty Registration Form, which is enclosed in the appliance document packet, to the following
address:
Hearthstone Quality Home Heating Products, Inc.
Warranty Department
317 Stafford Avenue
Morrisville, VT 05661
NOTE: SENDING IN THE SIGNED WARRANTY REGISTRATION FORM IS NOT REQUIRED AS A CONDITION OF
WARRANTY COVERAGE OR HEARTHSTONE’S PERFORMANCE.
St-jean-sur-Richelieu, February 6th 2018
Client: Hearthstone
Project: PI-20162
Model: GM-60
Page 23 of 28
M_rap_EPAwoodstove V1 – 2015 july 30th
APPENDIX 9: Test load photographs
Run 1
Run 2
Run 3
Run 4
Run 5