テキスト内容
この資料から読み取れるテキストです。
Declaration of Performance according to Regulation (EU) 305/2011
No. POV-HOX063/2019
1. Unique identification code of the product-type:
UKA 35/60/35/50Sh
2. Type, batch or serial number or any other element allowing identification of the construction
product as required under Article 11 (4): h49-001
Fireplace stoves burning wood made by Hoxter a.s. are designed for heating and additional heating of
residential and social rooms, i.e. standard environment without the explosion hazard and the presence of
volatile substances. The fireplace stoves are designed for interrupted operation.
Basic technical parameters
Type
Main dimensions
(mm)
Nominal
power
output
(kW)
Fuel
consumption
- wood
(kg/hour)
Diameter
of the
uptake
(mm)
Operational
draught
(Pa)
Height Width Depth
UKA 35/60/35/50Sh
1201
620
496
7
1,8
200
12
3. Intended use or uses of the construction product, in accordance with the applicable
harmonized technical specification, as foreseen by the manufacturer:
Room heater burning solid fuel. Appliances are determined for intermittent operation. According to
(ČSN) EN 13229/A2 Table 1 - "Sorting of appliances" it concerns products 1b.
4. Name, registered trade name or registered trade mark and contact address of the
manufacturer as required pursuant Article 11 (5):
HOXTER, a.s.
Jinacovice 512
664 34 Jinacovice
Czech Republic
IČ: 28359542
Tel.: +420 518 777 701
E-mail: info@hoxter.eu
5. Where applicable, name and contact address of the authorized representative whose
mandate covers the tasks specified in Article 12 (2):
N/A
6. System or systems of assessment and verification of constancy of performance of the
construction product as set out in Annex V:
System 3 (Annex V, Clause 1.4 of Regulation 305/2011 of the European Parliament and of the Council
of 9 March 2011)
7. The Declaration of Performance concerning a construction product covered by a harmonized
standard:
(ČSN) EN 13229:2001 /A2:2004/AC:2007 The assessment acc. to System 3 has been carried out by
Strojírenský zkušební ústav, s.p., Hudcova 424/56b, 621 00 Brno, Notified Body 1015, which issued
the Report on Initial Type Testing 30-14266/5 of 2019-10-18.
8. Declared performance:
Harmonized technical specification
EN 13229:2001/A2:2004/AC:2007
Essential characteristics
Performance
Fire safety
Reaction to fire
A1
Distance to combustible materials
Minimum distances, in mm
rear = 400
sides = 800
ceiling = 800
front = 800
Risk of burning fuel falling out
Pass
Emission of combustion products
CO[0,0755 %]
Surface temperature
Pass
Electrical safety
NPD*
Cleanability
Pass
Maximum operating pressure
NPD*
Flue gas temperature at nominal
heat output
T [194 °C]
Mechanical resistance (to carry a
chimney/flue)
NPD*
Thermal output
Nominal heat output
7 kW
Room heating output
7,7 kW
Water heating output
-
Energy efficiency
[83,2 %]
*) „NPD" (No Performance Determined),
9. The performance of the product identified in points 1 and 2 is in conformity with the declared
performance in point 8.
This Declaration of Performance is issued under the sole responsibility of the manufacturer identified
in point 4.
Signed for and on behalf of the manufacturer by:
Ing. Petr Veselský
Technical Director
In Jinacovice on 21.10.2019
…………….…………………………